169
Specifically, it is <nm> where n = 3 or 4 (and indicates the connector
grouping) and m = a,b,c, or d (and indicates the connector/path).
Connector-level
Path Parameters
This section describes connector-level path parameters applicable to
Ultra-WAN CSU/DSU connectors on the model S590/S598 PathBuilder
switches.
CLock
Syntax
SETDefault !<path> -PAth CLock = External | Internal
SHow [!<path> | !*] -PAth CLock
SHowDefault [!<path> | !*] -PAth CLock
Default
External
Description
The CLock parameter selects the clock source for the connector
transmitter. External is used for normal operation, indicating that the
transmit clock will be derived from the receive clock. Internal is for test
purposes, or in rare system topologies where the Ultra-WAN CSU/DSU
connector needs to source the system clock. When Internal is selected,
the transmit clock is derived from an onboard oscillator.
Before changes to this parameter can take effect a “SETDefault !<path>
-PATH ConnControl=Enable” command needs to be issued on the
corresponding connector.
CONNector
Syntax
SETDefault !<path> -PAth CONNector = [E1_Unstructured |
T1_Unstructured | E1_Pri | T1_Pri | E1_CHannelized |
T1_CHannelized ]
SHow [!<path> | !*] -PAth CONNector
SHowDefault [!<path> | !*] -PAth CONNector
Default
none
Description
The CONNector parameter specifies the connector type for an Ultra-WAN
CSU/DSU and Flex-WAN serial interfaces.
Before changes to this parameter can take effect, a “SETDefault !<path>
-PAth ConnCONTrol = Enable” command needs to be issued on the
corresponding connector.
Summary of Contents for 3C8S5007 - SuperStack II PathBuilder S500 Switch
Page 12: ......
Page 24: ...24 CHAPTER 1 OVERVIEW OF THE PATHBUILDER SWITCH ...
Page 36: ...36 CHAPTER 2 INSTALLING THE HARDWARE ...
Page 48: ...48 CHAPTER 3 LOGGING ON AND PERFORMING ADMINISTRATIVE TASKS ...
Page 66: ...66 CHAPTER 4 BASIC CONFIGURATION OF PORTS PATHS AND CONNECTORS ...
Page 76: ...76 APPENDIX A SERIAL DEVICES ...
Page 82: ...82 APPENDIX B TECHNICAL SUPPORT ...
Page 106: ...106 APPENDIX C CONNECTORS AND CABLES ...
Page 110: ...110 APPENDIX D CUSTOMIZING YOUR SOFTWARE ...
Page 138: ...138 APPENDIX E TROUBLESHOOTING ...
Page 142: ...142 APPENDIX F RELOADING THE SYSTEM SOFTWARE ...
Page 166: ...166 APPENDIX H COMPLETING THE ATM CONFIGURATION ...
Page 178: ...178 APPENDIX I COMMANDS AND PARAMETERS FOR ULTRA WAN CSU DSU INTERFACES ...