Example Configuration Templates
153
Example 8.
########################################################################
########################################################################
# ULTRAWAN CONNECTOR CONFIGURATION FILE
# E1 PRI TEMPLATE
# HOW TO CONFIGURE MULTIPLE CONNECTORS SIMULTANEOUSLY
# This example shows how to configure connectors 4A, 4B, 4C, and 4D
# simultaneously by creating an instance group of connectors and paths
# via the :Instance Group command. To specify which connectors are
# included in this grouping, just add or delete the according references
# in the Instance Group command. For example, to include only connectors
# 4A and 4C, the command would look like the following:
# Add -SYS InstanceGRoup E1PRI "!4A, !4C" PAth
# Add Instance Groups to cover all 4 UltraWAN connectors and selected paths
###### Note: E1PRI is short for E1, PRI dial
Add -SYS InstanceGroup E1PRI "!4A , !4B , !4C , !4D " PAth
# Connector-level path parameter configuration
# The following parameter settings are only typical example settings.
# Your network-specific settings need to be assigned by consulting the
# connector-level path parameter documentation in the document
# "Using the PathBuilder Switch"
SETDefault !E1PRI -PAth FrameMode = E1_CRC4
SETDefault !E1PRI -PAth CONNector = E1_Pri
SETDefault !E1PRI -PAth SwitchType = ETSI
SETDefault !E1PRI -PAth LineCoding = HDB3
SETDefault !E1PRI -PAth LineDistance = SH7
SETDefault !E1PRI -PAth CLock = External
# Enable Connectors
SETDefault !E1PRI -PAth ConnControl = Enable
# Add Instance Group to cover all paths on each UltraWAN connector:
###### Note: E1PRI4x is short for E1, PRI dial, all paths on 4x
Add -SYS InstanceGroup E1PRI4A "!4A.1 - !4A.30" PAth
Add -SYS InstanceGroup E1PRI4B "!4B.1 - !4B.30" PAth
Add -SYS InstanceGroup E1PRI4C "!4C.1 - !4C.30" PAth
Add -SYS InstanceGroup E1PRI4D "!4D.1 - !4D.30" PAth
# Path-level path parameter configuration
# The following parameters may need to be changed from their default
# settings, based on your specific environment topology:
#
# LocalDialNo: If you want outbound calls to provide a calling
Summary of Contents for 3C8S5007 - SuperStack II PathBuilder S500 Switch
Page 12: ......
Page 24: ...24 CHAPTER 1 OVERVIEW OF THE PATHBUILDER SWITCH ...
Page 36: ...36 CHAPTER 2 INSTALLING THE HARDWARE ...
Page 48: ...48 CHAPTER 3 LOGGING ON AND PERFORMING ADMINISTRATIVE TASKS ...
Page 66: ...66 CHAPTER 4 BASIC CONFIGURATION OF PORTS PATHS AND CONNECTORS ...
Page 76: ...76 APPENDIX A SERIAL DEVICES ...
Page 82: ...82 APPENDIX B TECHNICAL SUPPORT ...
Page 106: ...106 APPENDIX C CONNECTORS AND CABLES ...
Page 110: ...110 APPENDIX D CUSTOMIZING YOUR SOFTWARE ...
Page 138: ...138 APPENDIX E TROUBLESHOOTING ...
Page 142: ...142 APPENDIX F RELOADING THE SYSTEM SOFTWARE ...
Page 166: ...166 APPENDIX H COMPLETING THE ATM CONFIGURATION ...
Page 178: ...178 APPENDIX I COMMANDS AND PARAMETERS FOR ULTRA WAN CSU DSU INTERFACES ...