Table 37 describes power LEDs on the Fabric. (continued)
Troubleshooting the
Fan
If the fan OK LED is off, check that:
■
The fan has been installed in the correct position for normal communication
with the backplane.
■
Every heat dissipation fan is working normally.
■
There is nothing blocking the vent of the chassis.
■
The blanking plates are installed on the chassis where no module is inserted.
Table 38 describes fan LEDs on the Fabric. (continued)
Troubleshooting the
Modules
The Fabric and I/O module LEDs show the status of the FABRIC and the I/O
modules, as described in Table 39.
■
If the LED ALM of the module remains green or green flashing, it indicates
there is something wrong with the module.
■
During the process of resetting the module, the ALM LED remains on. After
normal booting, it is off.
■
When resetting the module, if the ALM LED remains off, the module may not
be connected to the power source. Check that the module has been properly
installed in the correct position. (continued)
Table 37
Power LEDs on the Fabric
LED
Status Description
OK
On — The power is working normally.
Off — The power has failed or has not been installed.
FAIL
On — The power has failed.
Off — The power is working normally or has not been installed.
Table 38
Fan LEDs on the Fabric
LED
Status Description
OK
On — The fan is working normally.
Off — The fan has failed or has not been installed.
FAIL
On — The fan has failed.
Off — The fan is working or has not been installed
Table 39
Module LEDs on the Fabric
LED
Status Description
RUN
Green/Off — The module has failed or has not been inserted.
Green flashing — The module is working normally.
ALM
Off — The module is working or has not been inserted.
Green or green flashing— The module has failed.