3

Operating instructions

3B SCIENTIFIC

® 

PHYSICS

U40110 Multiple Beam Lamp

1/03 ALF

1

Rotary mirror for focused, parallel light beams

2

Rotary mirror for divergent light beams

3

Protective cover

4

Electrical power cable with a 4-mm plug

5

Central ray

®

The multiple beam lamp allows numerous demonstra-
tions in the areas of ray and wave optics when used
with the equipment set for optics on magnetic boards,
basic set (U14600) and supplementary set (U14601). The
demonstrations include casting of shadows, chromat-
ics, reflection laws, refraction laws, total reflection,
minimum angle of deflection in a prism, ascertaining
the focal length of mirrors and lenses, lens laws and
aberrations.

1. Safety instructions

Caution: Lamps heat up during extended periods
of operation.

Do not touch the glass bulb of the lamp with your
bare hands when changing the bulb, for example.
Lamp bulbs are clouded by fat deposits on the
skin.

2. Description, technical data

The device comprises a halogen lamp in a metal hous-
ing lined with magnetic foil. The light source emits up
to 5 narrow beams which are deflected by rotary mir-
rors so as to emerge parallel, convergent or divergent.
Up to 2 divergent light beams whose area of overlap
can be adjusted by means of mirrors are available on
the rear of the multi-beam lamp.

Lamp:

12V, 55W

Power cable: 1.5 m long with a 4-mm plug

Dimensions:

150 mm x 200 mm x 50 mm

Weight:

0.9 kg

2.1 Accessories:

U40113 Spare halogen light for the multiple beam lamp
U40110.

3. Procedure

3.1 Setting a parallel light beam

Attach the lamp to the board.

Plug the lamp into a power supply unit, for in-
stance, U11735.

Adjust the beam via rotary mirror 1.

3.2 Setting a divergent light beam

Attach the lamp to the board.

Plug the lamp into a power supply unit, for in-
stance, U11735.

Adjust the beam via rotary mirror 2.

3.3 Changing bulbs

Loosen the screws, remove the round protective
cover (A) and the spacers.

Remove the flat plug (E), loosen the knurled screws
(B), remove the plate (C) and the lamp (D).

Insert a new lamp. Fasten the plate again with
knurled screws such that the lamp can still be
moved.

Do not touch the glass bulb of the lamp with your
bare hands when changing it. Lamp bulbs are

2

1

1

1

3

2

4

1

5

Summary of Contents for U40110

Page 1: ... 5 engen Lichtstrahlen die über drehbare Spiegel so umgelenkt werden dass sie parallel divergent oder konvergent aus der Leuch te austreten 1 bis 2 divergente Lichtstrahlen deren Überlappungs bereich über Spiegel eingestellt werden kann stehen auf der Rückseite der Vielstrahlleuchte zur Verfügung Lampe 12V 55W Anschlussleitung 1 5 m lang mit 4 mm Stecker Abmessungen 150 mm x 200 mm x 50 mm Masse 0...

Page 2: ...n nicht mit den Fingern berühren Lampen werden durch Hautfettablagerungen eingetrübt Flachstecker aufstecken Leuchte auf einen ebenen Tisch legen alle Drehspiegel nach außen drehen und Lampe an 6 Volt Spannung anschließen Lampe so verschieben dass alle Strahlenbündel gleich hell sind Rändelschrauben fest anziehen Abstandshülsen aufstellen Schutzdeckel aufsetzen und Schrauben anziehen ...

Page 3: ...lined with magnetic foil The light source emits up to 5 narrow beams which are deflected by rotary mir rors so as to emerge parallel convergent or divergent Up to 2 divergent light beams whose area of overlap can be adjusted by means of mirrors are available on the rear of the multi beam lamp Lamp 12V 55W Power cable 1 5 m long with a 4 mm plug Dimensions 150 mm x 200 mm x 50 mm Weight 0 9 kg 2 1 ...

Page 4: ...deposits on the skin Insert the flat plug Place the lamp on a level tabletop turn all rotary mirrors outward and connect the lamp to a 6V source Adjust the lamp so that all beams are equally bright Tighten the knurled screws Install the spacers and the protective cover and tighten the screws Figure 1 Bulb replacement A B C D E ...

Page 5: ...e trou vent à l arrière du projecteur multi faisceaux Lampe 12 V 55 W Câble de raccord 1 5mdelong avecdouillesde4mm Instructions d utilisation 3B SCIENTIFIC PHYSICS U40110 Projecteur multi faisceaux 1 03 ALF 1 Miroir tournant pour faisceaux parallèles étroits 2 Miroir tournant pour faisceau divergent 3 Couvercle de protection 4 Câble d alimentation électrique avec douilles de 4 mm 5 Faisceau média...

Page 6: ...ent légère ment les lampes Remettre la fiche plate Placer le projecteur sur une table plane tourner tous les miroirs vers l extérieur et brancher la lampe à une tension de 6 V Déplacer la lampe de manière à ce que tous les faisceaux présentent la même intensité Resserrer fortement les vis moletées Mettre les douilles d écartement en place remet tre le couvercle et resserrer les vis Figure 1 Rempla...

Page 7: ... sci luminosi stretti che vengono deviati da specchi gi revoli in modo tale da ottenere fasci paralleli diver genti o convergenti 1 o 2 fasci luminosi divergenti il cui settore di sovrapposizione può essere regolato mediante lo spec chio sono a disposizione sul retro del proiettore a rag gio multiplo Lampadina 12 V 55 W Cavo di collegamento 1 5mlungoconconnettoreda4mm Dimensioni 150 mm x 200 mm x ...

Page 8: ...re l ampolla del la lampadina con le dita L unto della pelle offu sca le lampadine Innestare la spina piatta Posizionare il proiettore su un tavolo piano ruotare verso l esterno tutti gli specchi girevoli e collegare la lampadina alla tensione a 6 Volt Spostare le lampadine in modo tale che tutti i fa sci di raggi siano ugualmente luminosi Serrare le viti a testa zigrinata Posizionare i tubi dista...

Page 9: ...s finos los cuales son desviados por el espejo giratorio de mane ra que salgan de la lámpara en forma paralela diver gente o convergente En la cara posterior de la lámpara multihaz se dispo ne de 1 a 2 rayos de luz divergente cuyo rango de su perposición se puede ajustar por medio del espejo Lámpara 12 V 55 W Cable de conexión 1 5 m de longitud con conector macho de 4 mm Dimensiones 150 mm x 200 m...

Page 10: ...Las lámparas se enturbian ante la acumulación de la grasa de la piel Colocar el conector plano Posicionar la lámpara sobre una mesa girar hacia afuera todos los espejos giratorios y conectar la lám para a una tensión de 6 voltios Desplazar la lámpara de manera que todos los ha ces de luz sean igualmente claros Apretar los tornillos moleteados Colocar los manguitos de separación la cubierta protect...

Page 11: ...caixa de metal recoberta de folha magnética Projeção de luz desde 1 feixe até 5 feixes de luz estreitos os quais podem ser dirigido pe los espelhos rotativos de forma a que saiam da lâmpa da paralelos convergentes ou divergentes 1 a 2 feixes de luz divergentes cuja superposição pode ser regulada por espelhos estão a disposição na parte traseira da lâmpada de feixes múltiplos Lâmpada 12V 55W Conexã...

Page 12: ...âmpadas com os dedos por exemplo ao trocar as lâmpadas as lâmpadas são cegadas pela gordura residual da pele Inserir a tomada plana Colocar a lâmpada numa mesa plana girar todos os espelhos para fora e conectar a lâmpada com a corrente de 6 Volts Posicionar a lâmpada para que todos os feixes te nham a mesma intensidade Apertar bem os parafusos Colocar as mangas de proteção fechar com a tam pa de p...