3A HEALTH CARE ASPEED PROFESSIONAL Instruction Manual Download Page 1

ISTRUZIONI D’USO
INSTRUCTION MANUAL
MANUEL D’INSTRUCTIONS
MONTAGE-UND GEBRAUCHSANWEISUNG
MANUAL DE INSTRUCCIONES

ASPEED

PROFESSIONAL

Summary of Contents for ASPEED PROFESSIONAL

Page 1: ...ISTRUZIONI D USO INSTRUCTION MANUAL MANUEL D INSTRUCTIONS MONTAGE UND GEBRAUCHSANWEISUNG MANUAL DE INSTRUCCIONES ASPEED PROFESSIONAL ...

Page 2: ... Switch 4 Air inlet connector INLET 5 Trasportation handle 6 Vacuum regulator 7 Vacuum gauge 8 1 000 ml Vessel 9 Protection device 10 Vessel plug 11 Antibacterial filter 12 50 cm silicon tube 1 Aspirador 2 Cable eléctrico 3 Botón ON OFF 4 Toma entrada aire INLET 5 Manija de transporte 6 Regulador de vacío 7 Vacuómetro 8 Vaso de 1 000 ml 9 Aparato de protección 10 Tapón para el vaso 11 Filtro antib...

Page 3: ...orps flottant en polypropylène stérilisable 5 Valve en caoutchouc stérilisable 6 Filtre antibactérien 7 Tuyau en silicone stérilisable Ø 6x12 mm 50 cm 8 Tuyau en silicone stérilisable Ø 6x12 mm 130 cm 9 Sac uniservice 10 Canule stérile uniservice 11 Régulateur manuel stérile uniservice 1 1 000 ml Sekretgefäß mit Siebdruck aus sterilisierbarem Polykarbonat 2 Sterilisierbarer Propylenstopfen 3 Schwi...

Page 4: ...a product equipped with the highest quality and safety features although being it an electric device some fundamental safety directions must be observed Kids and non self sufficient people must always use the device under strict supervision of a competent adult in his full capacity and who has read and understood this manual Ensure that children do not use the device unsupervised some parts are sm...

Page 5: ...on vessel and or without the antibacterial filter 5 1 1 Connection connect one end of the short sterilisable silicon tube 7 to the rubber holder of the antibacterial filter 6 and put the latter in the VACUUM VUOTO input of the blue lid 2 connect the other end to the INLET input of the aspirator Connect one end of the sterilisable silicon tube 8 to the PATIENT PAZIENTE input of the blue lid connect...

Page 6: ...be assimilated by the vessel figure 2a Check that the float is mounted in the right position and that it is free to slide inside the cage dirt and deposits can obstruct its movement PROBLEMS CAUSES AND SOLUTIONS PROBLEMS POSSIBLE CAUSES SOLUTIONS Excessive noise Damaged pump or obstructions in the internal suction duct Send to the customer care service The unit turns on but it does not suck Damage...

Page 7: ...0 MHz and 800 MHz the highest frequency range applies 2 These guidelines might not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 Rated maximum output power of transmitter W from 150 kHz to 80 MHz d 1 2 P from 80 MHz to 800 MHz d 1 2 P fr...

Page 8: ...dispose it as mixed solid municipal waste but dispose it referring to a specific collection centre located in your area or returning it to the distributor when buying a new device of the same type to be used with the same functions This procedure of separated collection of electric and electronic devices is carried out forecasting a European environmental policy aiming at safeguarding protecting a...

Page 9: ... fonctions Cette procédure de récolte séparée des appareils électriques et électroniques se réalise dans une vision d une politique de sauvegarde protection et amélioration de la qualité de l environnement et pour éviter des effets potentiels sur la santé humaine dus à la présence de substances dangereuses dans ces appareils ou bien à un emploi non autorisé d elles ou de leurs parties Attention Un...