Vision i Dome_VisionDome Installation Manual Ver 2.10
Page 13
© 360 Vision Technology Ltd.
8 VisionDome
8.1 Protocol Switch (S2)
Dil Switch Settings
1
Dome Address 1 to 256 range
Off
Dome Address 257 to 512 range
On
Dil Switch Settings
2
RS485 Termination Off (Not last camera in chain)
Off
RS485 Termination On (Last camera in chain)
On
Dil Switch Settings
3
4
5
6
360 Vision (Coax or RS485)
Off Off Off Off
Pelco D 9600 baud (or Coaxitron Extended)
On
Off Off Off
Pelco D 4800 baud (or Coaxitron Extended)
Off
On
Off Off
Pelco D 2400 baud (or Coaxitron Extended)
On On
Off Off
Pelco P 9600 baud (or Coaxitron Extended)
Off Off
On
Off
Pelco P 4800 baud (or Coaxitron Extended)
On
Off
On
Off
Pelco P 2400 baud (or Coaxitron Extended)
Off
On On
Off
BBV/Dennard (FSK Coax)
Off Off Off
On
Mark Mercer (FSK Coax)
On
Off Off
On
Ultrak (RS485)
On On
Off
On
VCL (Coax or RS485)
On On On
Off
Mark Mercer (RS485)* released November 2015.
On
Off
On On
Dil Switch Settings
7
Coax cable length 0m to 300m
Off
Coax cable length 300m to 1km
On
Dil Switch Settings
8
Dome will power up after a short delay
Off
Dome will power up after a 10min delay or PTZ command is received
On
1 2 3 4 5 6 7 8
ON
Example shows switch
settings for
Address range 1 to 256,
RS485 termination On,
360 Vision Protocol,
Short Coax cable run,
No 10 minute power up delay.
Switch is shown as