11 Special Presets

White Light

Exclusion

White Lights

(when it is dark)

Seek 100

(On)

White Lights

(change to colour, timer used)

Seek 101

(Off)

Night Sensor

(when it is dark)

Seek 67

(Mono)

Seek 68

(Colour)

Night Focus Range

(when it is dark)

Seek 69

(Ambient)

Seek 70

(IR)

Seek 82

Permanent Intermittent Wipe

De-Fog

Seek 87

(On)

Seek 88

(Off)

Washer

Seek 89

(Start)

Define Preset 359

(Defines Washer Position)

Seek 90

(Stop)

Illumination

(when it is dark)

Seek 64

(On)

IR

(mono/colour not changed)

Seek 66

(Off)

Seek 65

(On)

White Lights

(mono/colour not changed, no timer)

Seek 66

(Off)

Wiper

Seek 81

Double Wipe

Seek 86

(Stop)

Seek 84

Timed Intermittent Wipe

Seek 83

Permanent Fast Wipe

Seek 85

Timed Fast Wipe

Define 152

Set Right Side

Define 151

Set Left Side

See Page

 

23

Seek 103

Digital Zoom x2

Seek 102

Digital Zoom Off

Seek 105

Display Blue Spot, read Spot temperature

Seek 104

Digital Zoom x4

Seek 106

Remove Spot temperature

Define 105

White Hot

Seek 107

Turn off all thermal alarms

Define 107

Ice and Fire

Define 106

Black Hot

Define 108

Glow Bow

Define 109

Iron Bow

Define 111

Linear

Define 110

Histogram

Define 112

Auto Bright

Thermal Camera

(if fitted)

Define/Seek 150

Program/Recall Power on Park preset position.

Power on Park

Bright Control

Seek 240

(On)

Bright Control

(change to set brightness level)

Seek 249

(Off)

Set Privacy Zone

Seek 91

Scene being viewed

Clear Privacy Zone

Seek 92

Privacy zone being viewed

Clear Privacy Zone

Seek 93

All privacy zones

Summary of Contents for PRED-10M

Page 1: ...Predator Installation Manual Ver 2 9 Page 1 360 Vision Technology Ltd Predator Installation Configuration Manual ...

Page 2: ... 2 Washer Control PCB Setup 14 4 3 RS422 RS485 Converter 15 5 Predator Washer Nozzle Bracket 17 6 Connections to Predators with HMA 18 7 Basic Twisted Pair RS485 Data Wiring 19 8 Predator Protocol Address setup 19 9 Predator OSD 20 9 1 PIN Number 20 10 OSD Operation Navigation 21 11 Special Presets 25 12 Important Care of Painted Surfaces 26 13 Storage and Handling 26 14 Warranty 26 15 Camera Spec...

Page 3: ...nstallation should be carried out by suitably qualified personnel in accordance with local codes of practice and regulations 6 360 Vision Technology Limited accept no liability for any damage caused by incorrect or improper installation 7 To prevent risk of injury caused by the Predator or mounting options becoming detached fit a suitable safety chain or lanyard 8 Connection of data signals and po...

Page 4: ...PAN SWEEP NAME M5701 A PREDATOR ASSEMBLY SINGLE LAMP ALUMINIUM ISS DATE REFER A 060616 FIRST I 060616 DATE K CRAIK RELEASED APPROVED ENGINEER MATERIAL FINISH SINGLE IR LIGHTS SCALE 0 3 MOUNTING BASE SCALE 0 3 MUST NOT BE REPRODUCED OR SHOWN TO DO NOT SCALE ALL DIMENSIONS IN MM REMOVE ALL SHARP EDGES SHEET D C B A 4 3 2 1 4 3 2 1 A3 DESCRIPTION SCALE PERMISSION OF THE AUTHOR ANY THIRD PARTY WITHOUT...

Page 5: ...l Ver 2 9 Page 5 360 Vision Technology Ltd Weight 8kg Predator Thermal with Lamps Covers IR 75m IR or IRW 75m IR 50m White Light versions Weight 9kg Predator Single Lamps Straight Arm version Covers IR75 IR125 or IR100WL versions ...

Page 6: ...Thermal No Lamps Weight 9 5kg HMA Predator No Lamps shown All version of the Predator can be built to order with the integral HMA Hinged Mount Adapter The HMA is fitted during manufacture and is NOT available as an option for the installer to add to an existing Predator Weight 9kg ...

Page 7: ...edator Installation Manual Ver 2 9 Page 7 360 Vision Technology Ltd 3 Bracket Dimensional Drawing Weight 1 2kg Predator Wall Bracket Weight 2 2kg Predator Corner Bracket Weight 2 5kg Predator PMB Bracket ...

Page 8: ...logy com 125 OUTSIDE DIAMETER 9 x4 ON 101 6 4 INCH PCD USE M8 BOLT FOR FIXING TO POLE 60 M8 x4 ON 101 6 4 INCH PCD FIX PREDATOR USING M8x30 HEX HEAD BOLTS x4 STAINLESS STEEL M8 SPRING LOCK WASHER x4 STAINLESS STEEL 73 M20x1 5P M20x1 5P 73 M20x1 5P 8 0 x4 ON 101 6 4 INCH PCD FIX PREDATOR USING M8x30 HEX HEAD BOLTS x4 STAINLESS STEEL M8 SPRING LOCK WASHER x4 STAINLESS STEEL 5 3 0 125 OUTSIDE DIAMETE...

Page 9: ...e locking ring is tight Predator 12 way connector pin out White Band Predator Cable PRED Yellow Band Predator Cable PREDTH Cables for Connection to Predator Power Supply PRED 3M Pre made 3m cable PREDTH 3M Pre made 3m cable PRED 10M Pre made 10m cable PREDTH 10M Pre made 10m cable PRED 25M Pre made 25m cable PREDTH 25M Pre made 25m cable PRED 40M Pre made 40m cable PREDTH 40M Pre made 40m cable Op...

Page 10: ... Voltage 100 240VAC 50 60Hz Input current 2 1A Output Voltage 30V DC Output Current 6 2A Use pre made cable PRED 3M PRED 10m PRED 25m or PRED 40m to connect to Predator NOTE All wires in composite cable must be connected PRED PSU SM 255 x 180 x 100mm Enclosure Dimensions Analogue Version Wiring 24Vac PINK 24Vac GREEN 24Vac GREY 24Vac WHITE 24Vac BROWN 24Vac BLACK Coax Core Coax Screen RED ORANGE R...

Page 11: ... 2 1A Output Voltage 30V DC Output Current 6 2A ALARM INPUTS CON1 e g Connect A1 to COM to activate Alarm 1 ALARM RELAY OUTPUT CON3 Volts Free 0 5A 125Vac max 1A 24Vdc max PRED XALARM PSU SM A Use pre made cable PRED 3M PRED 10m PRED 25m or PRED 40m to connect to Predator NOTE All wires in composite cable must be connected 255 x 180 x 100mm Enclosure Dimensions 24Vac PINK 24Vac GREEN 24Vac GREY 24...

Page 12: ... the latest alarm has highest priority The Predator will seek the preset that corresponds with the new alarm When the contacts become inactive the Predator will seek the preset that corresponds with the previous highest priority alarm that is still active When all alarms inputs are inactive the alarm timer starts After the timer expires the Alarm PCB sends a command to the Predator to end the alar...

Page 13: ...27 28 29 30 31 32 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6...

Page 14: ...r supplies ordered with a Washer function are shipped pre built into the PSU weather proof box The washer control unit is programmed at manufacture to suit the protocol required and cannot be changed No further connections are required to this PCB during installation but address must be set to suit Aux Settings 1 Aux 2 Pelco default Off Aux 3 Pelco D 2400 only On 1 2 3 4 5 6 7 8 CON4 Address 1 7 R...

Page 15: ...ge 15 360 Vision Technology Ltd 4 3 RS422 RS485 Converter RS422 Tx Termination LK2 Use CON4 for RS422 Tx RS422 Rx Termination LK1 Use CON2 for RS422 Rx RS485 Pre wired CON3 for RS485 to camera Power Pre wired CON1 for 24Vac power connection ...

Page 16: ...ymmndd xxxx Input Voltage 100 240VAC 50 60Hz Input current 2 1A Output Voltage 30V DC Output Current 6 2A PRED PSU SM WA A Coax Core Coax Screen RED ORANGE RS485 D RS485 D Use pre made cable PRED 3M PRED 10m PRED 25m or PRED 40m to connect to Predator NOTE All wires in composite cable must be connected 255 x 180 x 100mm Enclosure Dimensions Coax Core TC Coax Screen TC 24Vac PINK 24Vac GREEN 24Vac ...

Page 17: ... reduce the risk of the bolt becoming loose and the bracket moving Ensure that the curved end of the bracket fixing plate is directed towards the Predator pan shaft so that the vertical part of the bracket is the maximum distance from the rotating body Tube Connection Suitable tube not supplied for connection to the nozzle is PVC with internal diameter 3mm and outside diameter 6mm PVC The end of t...

Page 18: ... to the top of the pole The hinged part of the HMA Hinged Mount Adapter is fastened to the fixed part using three M8x25 long hex head bolts Use a spanner 13mm to remove the three bolts Each bolt is fitted with a split spring lock washer a plain metal washer which prevents the split washer from damaging the fibre washer and a fibre washer which prevents the paint on the hinged part from being damag...

Page 19: ...tware Version PRO Protocol being used for telemetry e g 360 Vision Technology Ltd CAM Camera RS485 ID e g Cam 1 D If present dual addressing is enabled on the camera S or L Short or Long cable run Use the utility to set wether the coax used to send video is under or over 300m Second Line Shows the Predator Software Version loaded into the camera To change the above settings in the camera 360 Preda...

Page 20: ...vacy Zone 0 1 2 3 4 5 6 7 8 9 Accept Entry Clear Entry Return Exit SEEK PRIVACY ZONE Privacy Zone 0 1 2 3 4 5 6 7 8 9 Accept Entry Clear Entry Return Exit REMOVE PRIVACY ZONE Privacy Zone 0 1 2 3 4 5 6 7 8 9 Accept Entry Clear Entry Return Exit FINISH MIMIC BY DEFINING ANY PRESET No ACTION SEEK 01 a none NO 02 b none NO 03 c none NO 04 d none NO 05 e none NO 06 f none NO 07 g none NO Accept Change...

Page 21: ...belled above PREDELSPD PRE is preset position DEL is delay in seconds and SPD is speed at second This is how the camera will be programmed to move to a preset for a period of time at a set speed All nine figures must be added into the item Figures must be added in three i e preset 21 will be added as 021 Example of an item point 021005100 Move to preset 21 for 5 seconds at 100 sec Highlight ACCEPT...

Page 22: ...will re initialise camera motors so that camera looks back to the original position if the camera is physically forced moved Default is on General 3 Wiper Rest Input a rest time for the wiper See also Special Presets page 25 Wiper On Time h m s Input a time period for the wiper operation See also Special Presets page 25 Wiper Permanent Enable or disable the permanent wiper time period FV Text Cont...

Page 23: ... Set if white lights are to be used if an alarm is triggered This feature works with 360 Standalone alarmcard or 360 Vision Matrix only White Timeout Use if a white light timer is required Default is on White Timeout m Set white light timer for automatic switch off Auto Dimming When selected the camera will reduce the lamp power when looking in scenes where there is too much light FV White Lights ...

Page 24: ...uired Servicing Power Reset This will reboot the camera no settings will be lost Factory Reset This will reboot the camera and all the settings will be lost Predator Software Version This shows the software version of the camera Privacy Zone Menu Can be used to obscure a scene within an image e g private residence Move the camera to the position required for the privacy zone before going into the ...

Page 25: ... 86 Stop Seek 84 Timed Intermittent Wipe Seek 83 Permanent Fast Wipe Seek 85 Timed Fast Wipe Define 152 Set Right Side Define 151 Set Left Side See Page 23 Seek 103 Digital Zoom x2 Seek 102 Digital Zoom Off Seek 105 Display Blue Spot read Spot temperature Seek 104 Digital Zoom x4 Seek 106 Remove Spot temperature Define 105 White Hot Seek 107 Turn off all thermal alarms Define 107 Ice and Fire Defi...

Page 26: ...ging which is used for despatch from the factory they should not be stacked to a height of more than two Predators When Predators are being stored before installation they should be kept in the transit packaging and located in a dry indoor environment preferably between 1 C and 35 C which is dry and dust free Humidity should such that water vapour is non condensing Predators can be allowed to be o...

Page 27: ...ng Auto Homing Preset Tour or Mimic Col Mono Changeover 4 levels 3 fixed preset 1 user defined Operating temperature 40 C 60 C with optional heater Power 24Vac dc Certification CE approval IP68 16 PSU Enclosure Material PC ABS Dimensions PRED PSU SM enclosure 255 x 180 x 100mm Predator Specification 18x 28x 44x Colour Mono Yes Imager 1 4 type Super HAD CCD II Zoom Optical Digital 18x 12x 44x 12x P...

Page 28: ...Predator Installation Manual Ver 2 9 Page 28 360 Vision Technology Ltd ...

Reviews: