Eclipse HD SS v2.1.22
Page 5
© 360 Vision Technology Ltd.
The Ethernet connection uses standard CAT5, CAT5e or CAT6 cables fitted with RJ45 connectors.
RJ45
CAT5, CAT5e, CAT6 Cable
Signal
Pin 1
White with Orange Band
Tx+
Pin 2
Orange
Tx-
Pin 3
White with Green Band
Rx+
Pin 4
Blue
Pin 5
White with Blue Band
Pin 6
Green
Rx-
Pin 7
White with Brown Band
Pin 8
Brown
The power connection is supplied as a standard length of 2m cable (red/black)
• 24Vdc - 36Vdc (Max)
• 24Vac - 28Vac (Max)
The washer connection is supplied as a standard length of 2m cable (orange/white)
• Normally Open Volt Free contact
• Contact ratings - 1A 30Vdc (Resistive) or 0.5A 125Vac
3.1 Washer Connection
MUST NOT BE REPRODUCED OR SHOWN TO
DO NOT SCALE
ALL DIMENSIONS IN MM
REMOVE ALL SHARP EDGES
SHEET:
D
C
B
A
D
C
B
A
4
3
2
1
4
3
2
1
A3
DESCRIPTION
SCALE:
PERMISSION OF THE AUTHOR.
ANY THIRD PARTY WITHOUT THE DIRECT WRITTEN
C COPYRIGHT PROTECTED AND
THIS DRAWING AND ALL COPIES ARE
PART NUMBER:
0.167
3 OF 3
TOLERANCES:-
X = 0.5
X.X = 0.1
X.XX = 0.05
A3
3rd ANGLE PROJECTION
360 Vision Technology Ltd.
Unit 7, Seymour Court,
Manor Park, Runcorn, Cheshire,
WA7 1SY. United Kingdom.
www.360visiontechnology.com
365.0
PAN
SWEEP
490
TILT
SWEEP
215.0
9.0 (x4) ON
101.6 (4") PCD
51.0
125
MOUNTING
BASE
NAME:
M5650-B
ECLIPSE STAINLESS STEEL
ASSEMBLY AND BOM
ISS DATE
REFERENCE
A 250816
FIRST ISSUE
B 160916
TILT AND SWEEP UPDATED
250816
DATE :
K.CRAIK
RELEASED:
APPROVED:
ENGINEER:
-
-
MATERIAL:
FINISH:
SCALE 0.3
SCALE 0.3
SCALE 0.25
MOUNT PLATE
Tube Connection
• Suitable tube (not supplied) for connection to the nozzle is PVC with internal diameter 3mm and
outside diameter 6mm PVC.
• The end of the tube is pushed over the ridged tube. Fit a cable tie around the joint between the PVC
tube and the ridged tube to ensure that the tube can not become detached.