TSS MINI Operations Manual
Page 87
Configuring NTP
The server GUI is used to set the time zone and to enter the networking parameters. The
local GUI must be used, as these configuration screens are not available on the Remote
Workstation Interface.
Selecting the Time Zone
Starting at the main menu bar, Click
Edit >Configure >Date-Time
screen
. When
“Automatic Updates” is not checked, the Region and Zone lists are enabled. Select your
region and then the zone within that region. There may be more than one way to your zone;
America/New York, for example, is the same as US/Eastern. Click the
APPLY
button to
activate the settings,
After changing the time zone a Quick Restart must be performed before changes become
effective.
Figure 29 - Date/Time Configuration Screen
When
Automatic updates
is checked, all functions on this page are locked out as they are
automatically adjusted by the NTP service. The NTP Status will be updated when the NTP
service checks the time, displaying the current Offset and Frequency adjustments to the
clock.