96
Hard Disk Management
Rebuilding the RAID Array
Figure 27: Selecting a Drive to Use In Rebuilding the Array
•
Select
Rebuild Unit
. The REBUILD SCREEN above will appear.
•
Select the available drive by clicking the check box.
•
Press
OK
. The RAID array will begin rebuilding with the ne w drive.
This process may take a long time, but the Image Server can still be used.
•
When complete, OK will be shown in the status for all ports on the MAINTENANCE menu.
Replacing Hard Drives
The Image Server hard disk drives have been factory tested and configured in a RAID 5 array. Each
drive is numbered (0-3) and must be attached to the correctly numbered data cable. Drive bays are
also numbered.
Please read
Removing the Front Panel
on page 104 for instructions on accessing the hard drive
bays. Detailed information about how to replace hard drives is on page 111.