The Boltz Group warrants to the original pur chas er that the Natural Gas Conversion Kit

 

is free from defects due to workmanship or materials for 1 Year when 

installed by a professional service technician.

The Boltz Group ’s obligations under this warranty are limited to the following guidelines:

•  This warranty does not cover conversion kits that have been altered/modifi ed or damaged due to: normal wear, rust, abuse, improper maintenance 

and/or improper use.

•  This warranty does not cover surface scratches, rust or heat damage to the fi nish, which is considered normal wear.

•  The Boltz Group may elect to repair or replace damaged units covered by the terms of this warranty.

•  This warranty extends to the original purchaser only and is not trans fer able or assignable to subsequent purchasers.

The Boltz Group requires reasonable proof of purchase. Therefore, we strongly recommend that you retain your sales receipt or invoice. To
obtain replacement parts for your Natural Gas Conversion Kit under the terms of this warranty, please call Customer Service Department at 
855-735-9922 

A receipt will be required.

 The Boltz Group 

 will not be responsible for any conversion kits forwarded to us without prior 

authorization.

EXCEPT AS ABOVE STATED, 

THE BOLTZ GROUP 

MAKES NO OTHER EXPRESS WARRANTY.

THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THOSE LISTED 
ABOVE FROM THE DATE OF PURCHASE. SOME STATES DO NOT ALLOW LIM I TA TIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE 
ABOVE LIMITATION MAY NOT APPLY TO YOU.

ANY LIABILITY FOR INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE FAILURE OF THE NATURAL GAS CONVERSION KIT

 

TO 

COMPLY WITH THIS WARRANTY OR ANY IMPLIED WARRANTY IS EXCLUDED. CUSTOMER ACKNOWLEDGES THAT THE PURCHASE PRICE CHARGED 
IS BASED UPON THE LIMITATIONS CONTAINED IN THE WARRANTY SET OUT ABOVE. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION 
OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU 
SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.

WARRANTY

Las autorizaciones de The Boltz Group al comprador original que equipo universal de conversión del gas natural está libre de los defectos debido a la 
ejecución o a los materiales por 1 año cuando es instalado por un técnico del servicio profesional. Las obligaciones de 3 Embers con respecto a esta 
garantía se limitan a lo siguiente:

•  Esta garantía no cubre equipos de conversión que hayan sido alteradas/modifi cado o dañadas debido a: uso normal, herrumbre, maltrato, 

mantenimiento inadecuado y/o uso inapropiado.

•  Esta garantía no cubre rayones superfi ciales, daño por herrumbre o por calor al acabado, lo cual se considera como uso normal.

•  The Boltz Group puede decidir reparar o reemplazar las unidades dañadas cubiertas bajo los términos de esta garantía.

•  Esta garantía se otorga al comprador original únicamente y no es transferible o asignable a los compradores posteriores.The Boltz Group exige un 
comprobante de compra razonable. Por lo tanto, le recomendamos enfáticamente que retenga su recibo o factura de venta. Para obtener partes de repuesto 
para el equipo de conversión universal del gas natural  bajo los términos de esta garantía, sírvase contactar al Departamento de Servicio al Cliente al 

855-

735-9922

Se exigirá la presentación de un recibo. 

The Boltz Group

 no será responsable de ningun equipo de conversión devuelta a nosotros sin 

autorización previa.

EXCEPTO POR LO INDICADO ARRIBA, THE BOLTZ GROUP NO OTORGA NINGUNA OTRA GARANTÍA EXPRESA. LAS GARANTÍAS IMPLÍCITAS 
DE COMERCIABILIDAD Y ADECUACIÓN CON UN FIN EN PARTICULAR SON DE DURACIÓN LIMITADA DE ACUERDO A LO INDICADO ARRIBA A 
PARTIR DE LA FECHA DE COMPRA. ALGUNOS ESTADOS NO PERMITEN LIMITACIONES DE DURACIÓN DE UNA GARANTÍA IMPLÍCITA; POR LO 
TANTO, LA LIMITACIÓN ANTERIOR PODRÍA NO SER APLICABLE EN SU CASO.

SE EXCLUYE CUALQUIER RESPONSABILIDAD POR DAÑOS INDIRECTOS, INCIDENTALES O CONSIGUIENTES DERIVADOS DE LA FALTA DE 
CUMPLIMIENTO DE ESTA GARANTÍA O DE CUALQUIER GARANTÍA IMPLÍCITA DE 3 EMBERS EQUIPO DE CONVERSIÓN UNIVERSAL DEL GAS 
NATURAL. EL CLIENTE RECONOCE QUE EL PRECIO DE COMPRA COBRADO SE BASA EN LAS LIMITACIONES CONTENIDAS EN LA GARANTÍA 
ANTERIOR. ALGUNOS ESTADOS NO PERMITEN LA EXCLUSIÓN O LIMITACIÓN DE LOS DAÑOS INCIDENTALES O CONSIGUIENTES; POR 
LO TANTO, LA LIMITACIÓN O EXCLUSIÓN ANTERIOR PODRÍA NO SER APLICABLE EN SU CASO. ESTA GARANTÍA LE OTORGA DERECHOS 
LEGALES ESPECÍFICOS Y USTED PUEDE TENER ADEMÁS OTROS DERECHOS QUE VARÍAN DE UN ESTADO A OTRO.

GARANTÍA

Summary of Contents for GAS8490AS

Page 1: ...INSTALADOR ENTREGUE ESTAS INSTRUCCIONES AL PROPIETARIO DE LA PARRILLA PARA REFERENCIA FUTURA HAZARDOUS EXPLOSION MAY RESULT IF THESE WARNINGS AND INSTRUCTIONS ARE IGNORED READ AND FOLLOW ALL WARNINGS...

Page 2: ...___________ Failure to follow the instructions as written or installation by other than a trained professional will void all manufacturer warranties WARNING This conversion kit shall be installed by a...

Page 3: ...any If the supply pressure is different than 7 inch contact a professional service technician for assistance Not for use with LP gas WARNING FOR OUTDOOR USE ONLY DO NOT operate indoors or in an enclos...

Page 4: ...ay near this grill DO NOT leave the grill unattended while in use DO NOT allow the gas hose to come in contact with hot surfaces DO NOT allow grease from drain hole to fall on hose Keep any electrical...

Page 5: ...AD ALL SAFETY WARNINGS ASSEMBLY INSTRUCTIONS CAREFULLY BEFORE ASSEMBLING OR OPERATING THE CONVERTED GRILL The following tools are required to assemble the Conversion Kit Phillips and Flathead Screwdri...

Page 6: ...ll Step 1 Using an adjustable wrench to hold the gas connection secure use a 3 4 wrench to loosen the hose connection nut Replace existing LP hose regulator assembly with natural gas 10 hose assembly...

Page 7: ...Step 4 Use the gas orifice tool to remove the LP brass orifice from each main burner valve through the hole on the firebox front panel Note All orifices of the grill are double orifices LP gas and na...

Page 8: ...ill notice the knobs will stop at the MED setting on the dial This is the correct low setting for natural gas Do not try to turn the knob to LO setting Step 7 Carefully replace each burner making sure...

Page 9: ...ward locking plug into socket Be sure to leak test these connections prior to use Pipe nipple Quick disconnect coupling Plug Push sleeve back to attach Sleeve Socket Natural gas supply Natural gas sup...

Page 10: ...l is still hot DANGER WHEN TO PERFORM A LEAK TEST After assembling or converting your natural gas grill and before lighting for the first time even if purchased fully assembled Any time the gas compon...

Page 11: ...growing bubbles which indicates a leak 8 Turn off gas supply at source 9 Turn on control knobs to release gas pressure in hose 10 Turn control knobs to OFF position 11 Tighten any leaking connections...

Page 12: ...lit Flame should be a Blue Yellow color between 1 2 when burner is on HIGH WARNING Property damage bodily harm severe burns and death could result from failure to follow these safety steps These step...

Page 13: ...escritas dadas aqu se ignoran o una persona que no sea un profesional capacitado instala el aparato toda garant a del fabricante quedar anulada ADVERTENCIA Este equipo de conversi n deber ser instalad...

Page 14: ...serve una distancia m nima de 36 pulgadas 91 cm entre todos los lados de la parrilla del barandal de la cubierta de un muro u otro material combustible NO utilice la parrilla debajo de construcciones...

Page 15: ...ermita que los ni os utilicen la parrilla para jugar o jueguen cerca de ella NO deje la parrilla desatendida cuando la est utilizando NO permita que la manguera de gas toque superficies calientes NO p...

Page 16: ...E SER UN T CNICO PROFESIONAL DE SERVICIO PARA CONVERTIR ESTA PARRILLA LEA DETENIDAMENTE TODAS LAS ADVERTENCIAS DE SEGURIDAD E INSTRUCCIONES DE ENSAMBLADO ANTES DE ARMAR U OPERAR LA PARRILLA CONVERTIDA...

Page 17: ...able para detener bien la conexi n del m ltiple del gas use una llave de tuercas de 3 4 para aflojar la tuerca de conexi n de la manguera Reemplace el ensamblado manguera regulador para gas LP existen...

Page 18: ...ra quitar el orificio de lat n para el gas LP de las v lvulas del quemador principal introduci ndola a trav s del agujero en el panel frontal de la c mara de fuego Nota Todos los orificios de la parri...

Page 19: ...e detendr n en el ajuste MED del dial Este es el ajuste correcto para el gas natural No intente girar la perilla a la posici n LO Paso 7 Vuelva a conectar con cuidado Reemplace cada quemador de tal mo...

Page 20: ...tap n en el recept culo No se olvide realizar la prueba de detecci n de fugas en estas conexiones antes del uso Tubo Corto Enroscado Acoplamiento de Desconexi n R pida Tap n Empuje el manguito hacia...

Page 21: ...IZAR UNA PRUEBA DE DETECCI N DE FUGAS Tras haber ensamblado o convertido su parrilla para usarla con gas natural y antes de encenderla por primera vez incluso si la compr totalmente ensamblada Cada ve...

Page 22: ...dejar salir la presi n del gas en la manguera 10 Gire las perillas de control a la posici n de APAGADO 11 Apriete toda conexi n con fugas 12 Repita la prueba con el agua jabonosa hasta no detectar nin...

Page 23: ...contenida en las secciones anteriores de este manual Nota Observe la flama encendida debe tener una altura entre 1 y 2 pulgadas cuando el quemador est en posici n ALTO y ser de color azul o amarillo 2...

Page 24: ...O STATE WARRANTY Las autorizaciones de The Boltz Group al comprador original que equipo universal de conversi n del gas natural est libre de los defectos debido a la ejecuci n o a los materiales por 1...