6. installation
6. installation
10
11
the electrical parameters are shown on
•
the manufacturer’s label, which is located
under the air curtain’s service cover.
The air curtain must be protected by
•
an appropriate circuit breaker, in accor-
dance with its electrical parameters. For
safety reasons, over-designed protection
is not recommen-ded.
The air curtain must be connected using the
•
TN-S system, which means that the neutral
conductor must always be connected.
A main cut-off switch must be placed in the
•
electrical supply network, disconnecting
all poles of the network.
The electrical enclosure of the curtain is IP20.
•
VENESSE
Comfort
air curtains are equipped
with an 8A rated fuse. This safety fuse protects
the electronic panel and fans. It is located on
the electrical board next to the connectors for
the door contact switches and other switches.
6.4 install tHE ContRol PanEl
15/16 17/18
8 A
Air curtain Type
Serial number
U = Voltage
f = Frequency
n = Speed
ph = Phase
av = Air output
I = Net current
P = Output
m = Weight
IP = IP rating
ver =
DM control for air curtain
without heater
DM control for
air curtain with electric
heater or with water
heater
1
2
3
0
1
2
1
2
3