background image

11

2VV.

 Creating innovative solutions for you and your business since 1995.

STORAGE AND DISPOSAL

STORAGE

Store the controller as follows:

Wrap the controller in suitable material, such as plastic film, canvas etc. or place it in a suitable box.

Transport the controller into a dry space that is protected from weather conditions that could damage the packaging and negatively 

affect the controller. The ambient temperature must be b5 °C and +40 °C.

Do not place any heavy objects or material on top of the stored controller.

DISPOSAL ONCE THE CONTROLLER IS OUT OF OPERATION

When disposing of the controller, follow relevant regulations on waste disposal. It is best to dispose of components at a 

specialised collection point to ensure recyclable materials are reused. Take any non-reusable parts of the air curtain to a 

controlled waste dump. 

RULES FOR SAFE OPERATION

 

Control and operate the controller only in accordance with this manual.

 

Always abide by the controllers operating temperatures.

 

Do not overstress the structure of the controller.

 

The controller should be protected by a suitable circuit breaker

In the event of fire, the controller must be extinguished with a CO

2

 or powder fire extinguisher. Never extinguish it with water!

2VV, s.r.o.

Fáblovka 568,

533 52 Pardubice,

Czech Republic

 

T: 

+420 466 741 811

E: 

[email protected]

W: 

www.2vv.cz

Summary of Contents for AirGENIO

Page 1: ...Installation and operation instructions EN AirGENIO BASIC EC controller...

Page 2: ......

Page 3: ...carefully Proceed exactly according to the instructions stated here in order to install controller properly and safely Do not put the device into operation unless you are thoroughly acquainted with al...

Page 4: ...troller from the box DEVICE DESCRIPTION INTRODUCTION AirGENIO BASIC EC controller is designed to control the air curtains and heating units with electric or water coils using manual heating control an...

Page 5: ...an speed heating enabled Heat level 1 and 2 enable 4 High fan speed heating enabled Heat level 1 and 2 enable 5 Heat switch Water heater Heat level 1 Electric heater Heat level 1 and 2 1 2 3 4 5 OPERA...

Page 6: ...NTROLLER SWITCH FOR 1ST HEAT STAGE FACTORY CONNECTED S COM OF INTERNAL HEAT SWITCH FACTORY CONNECTED S2 SWITCH FOR 2ND HEAT STAGE FACTORY CONNECTED RT ROOM THERMOSTAT DI SWITCHING ON OFF HEAT OUTPUTS...

Page 7: ...lled EC fan in the product is able to start before 1 7V control signal to avoid start heating earlier then fan starts HEAT 1 H1 output is active when starting 1st stage of heating as well as at start...

Page 8: ...ative solutions for you and your business since 1995 WIRING EXAMPLES BASIC EC AGBA1 M ECx xx E2 with two EC fans and electric heater with two steps of heating BASIC EC AGBA1 M ECx xx V1 with two EC fa...

Page 9: ...10 2VV Creating innovative solutions for you and your business since 1995 BASIC EC AGBA1 M ECx xx S0 with two EC fans BASIC EC AGBA1 M ECx xx V1 with two EC fans Electric heater with one step...

Page 10: ...PERATION When disposing of the controller follow relevant regulations on waste disposal It is best to dispose of components at a specialised collection point to ensure recyclable materials are reused...

Reviews: