9
2VV.
Creating innovative solutions for you and your business since 1995.
MENU - SUBUNITS
Use this menu to set the behaviour of the IC-S regulators
connected as SLAVE
Number of SLAVE
regulators:
0 ~ 10
Ad 1)
Ad 2)
Ad 1)
– Use one door contact as main. Its status will be sent to the
SLAVE regulators and it will no longer be necessary to connect it to each
regulator, if required.
Not allowed = the door contact will not transmit to the SLAVE regulator from the MASTER
Allowed = the door contact will transmit to the SLAVE regulator from the MASTER
Ad 2)
– Activates in the main screen the icon to turn
each SLAVE regulator ON/OFF If inactive, all the SLAVE
regulators will be turned on or off simultaneously
Not allowed = The SLAVE regulators are turned on/off simultaneously
Allowed = The SLAVE regulators can be turned on/off individually
form the main screen
1. CONTROL
Slave address parameter:
ADDRESS
SLAVE UNIT
ADDRESS
SLAVE UNIT
1
1
6
6
2
2
7
7
3
3
8
8
4
4
9
9
5
5
A
10
This MENU is available only for units with water heat exchanger
it allows for advanced setting of water heat exchanger regulation.
The MENU for setting the blowers when closing and opening
doors. It allows for advanced settings of blower control.
Setting blower power limits
for open doors.
Min - Max
The time for which the blower
will be operational from the mo-
ment the desired temperature is
ac0.3°C on the ROOM
sensor in closed door mode. This
setting is available only when
the ROOM regulation sensor
is selected (1616/Temperature
sensor)
The set limits on blower power restrict the extent of blower control for open and closed
doors. This restriction is applied to manual and automatic control of blower power. Exceed-
ing limits in any blower power setting is signalled when the setting element turns red with
the text overruns.
Setting blower power limits
limits for
closed doors.
Min - Max
Maximum temperature for
return water
Setting periods for
blower movement.
Only at 0:00 time and in
Standby mode.
Minimum water flow
can be set only for
analog control of blower.
MENU - Adv. WATER SETTING
MENU - Adv. fan setting