Upgrade

The Upgrade menu helps you upgrade the firmware, bootloader and voice menu. Select
the file to be loaded in the File name section for the program to automatically read the
type from the file header and display it as the file type: Firmware, Bootloader or Voice
menu. Click Select to select a file and press Upgrade to make 

2N  Lift1 Service Tool 

®

upload the new Firmware, Bootloader or Voice menu version into the audio unit.

Device / Upgrade Menu

Figure: 

Caution

After the firmware, bootloader or voice menu upgrade, the audio unit will
be  restarted  automatically  and  the  application  will  be  disconnected. 
Reconnection  will  not  be  possible  until  the  audio  unit  has  executed
upgrade and restart.

Summary of Contents for Lift1 Compact

Page 1: ...www 2n cz Version 2N Lift1 Communicator for lifts User manual 1 0...

Page 2: ...s and or trademarks or brands protected by law 2N TELEKOMUNIKACE a s administers the FAQ database to help you quickly find information and to answer your questions about 2N products and services On ww...

Page 3: ...3 Configuration 35 3 1 2N Lift1 Programming 36 3 2 Table of Parameters 40 3 3 2N Lift1 Programming Tool 50 4 Function and Use 52 4 1 Function Description 53 4 2 Service and Operating Staff Instruction...

Page 4: ...ction we introduce the 2N Lift1 product outline its application options and highlight the advantages following from its use Here is what you can find in this section 1 1 Product Description 1 2 Compon...

Page 5: ...be used for making calls to pre programmed numbers and cannot be misused for calling at somebody else s account 2N Lift1 can be equipped with various extending modules as necessary during and after pu...

Page 6: ...s prepared for installation in advance Part No Name Description 919640 2N Lift1 Cabin audio unit basic module fully extendable automatic dialling of up to 6 numbers factory announcements are played ow...

Page 7: ...includes two switches or one switch one blocking module 913649E 2N Lift1 Blocking module A special switch that helps block a lift in the event of telephone line error 913650E 2N Lift1 Amplifier module...

Page 8: ...8 2N TELEKOMUNIKACE a s www 2n cz Programming Tool Part No Name Description 919680E 2N Lift1 Programming Tool Used for interconnection of and 2N Lift1 2N Lift1 via USB Service Tool...

Page 9: ...to the machine room through which the telephone wires line passes Associated 2N Products 918xxx 2N Lift8 System Up to 8 lift connectivity Cabin shaft and machine room audio units In built backup recha...

Page 10: ...10 2N TELEKOMUNIKACE a s www 2n cz 5013331E 2N EasyGate PRO GSM Gateway incl backup 2N Lift1 batteries Fixed telephone line substitution Easy installation no configuration...

Page 11: ...Supply for 2N EasyGate 501303 501313 Backup power supply for power outage Easy installation Cooperating 2N Applications 918700E 2N Lift8 Control Panel Obr zek 2N Lift8 Control Panel The application i...

Page 12: ...8 Communicator The application is designed for receiving alarm calls by 2N Communicator Lift8 Dispatcher 918700E 2N Lift8 Server Obr zek 2N Lift8 Server The application processes check calls and media...

Page 13: ...on Description of changes 1 0 First product manual version Functional replacement of the 91364X series 2N Single Talk Caution The manufacturer keeps upgrading the software according to the customers n...

Page 14: ...unctions and features that are grey marked under preparation or development at present Safety by this information to prevent persons from injury Always abide Warning by this information to prevent dam...

Page 15: ...stallation In this section we describe the product and its installation 2N Lift1 Here is what you can find in this section 2 1 Product Description 2 2 Before You Start 2 3 Mounting Universal Design 2...

Page 16: ...ly The Connection established pictogram starts shining when communication has been established Universal Design The electronics board is located between the mounting panel and the cover printed with i...

Page 17: ...ons 2N Lift1 is not intended for outdoor applications As the product is connected to a telephone line and may thus produce life endangering voltage follow the safety precautions refer to Electric Inst...

Page 18: ...may never exceed the panel size acoustic fault microphone hole and two LED holes if necessary Safety The telephone line microphone speaker LED indicators ALARM button CANCEL input cables and electron...

Page 19: ...19 2N TELEKOMUNIKACE a s www 2n cz Mounting Drawing for 50 mm Speaker Installation...

Page 20: ...e printed circuit see the drawing for its position If required the microphone can be supplied with a cable mounted on a 25 25 mm holder with self adhesive foil This allows you to mount the microphone...

Page 21: ...in instead of noise from the shaft or space behind the panel Caution Installing the speaker separately make sure that the grid cannot surpass eliminate the acoustic fault the speaker dimensions in any...

Page 22: ...sure that the electric isolation between the panel and speaker is 1500 V at least Also make sure that the isolation distance between the panel and speaker is 1 5 mm at least It is prohibited to use s...

Page 23: ...ctors and Jumpers Terminals Jumper Setting Left jumper Right jumper ALARM input inversion PROGRAMMING disable up contact or voltage connection control closing up enabled down contact or voltage discon...

Page 24: ...24 2N TELEKOMUNIKACE a s www 2n cz Connectors Accessible after Cover Removal Tip To access the connectors on the lower edge of the board loosen the cover screws slightly and move the cover upwards...

Page 25: ...one is connected upon request the integrated microphone is disconnected automatically Speaker connector The speaker is connected to this connector by default Induction loop connector optional The indu...

Page 26: ...power supply for its function Refer to Connecti 2N Lift1 on Methods for PSTN PBX GSM connection details ALARM Connection Contact Control Connect the button contacts to the ALARM terminal leaving the t...

Page 27: ...ated during the whole connection setup time when external indicators are used Requirements 12 24 V power supply backed up against power outage if required Up to 200 mA continuous current bulbs can be...

Page 28: ...ion Caution The door switch or door opening signal indicates that the door is open only if both the internal and external lift doors are open and people can leave the cabin Note To use the CANCEL inpu...

Page 29: ...sons with defective hearing in the lift cabin In that case connect the loop to the connector as shown in the Connectors Accessible after Cover Removal figure with any polarity The loop including a 1m...

Page 30: ...Install the Universal switch module Part No 913648E to position 1 or 2 before installing your without removing the cover Slide the module into 2N Lift1 2N Lift1 the cut outs on the motherboard edges a...

Page 31: ...ge for metering The maximum current to be switched is 1 A The switch is protected against higher current values with a resettable fuse The allowed voltage is 9 to 24 V DC AC The switch is protected ag...

Page 32: ...32 2N TELEKOMUNIKACE a s www 2n cz Amplifier Installation Follow the instructions enclosed to the amplifier delivery...

Page 33: ...te The telephone socket including the wires is the property of the telephone provider and may not be tampered with Make sure that your follow up cables meet the applicable safety regulations Submit th...

Page 34: ...e Identify the line extension and type of incoming connection dial in DISA operator and configure the PBX to allow for incoming calls at night 2N Lift1 too i e without operator Set the required author...

Page 35: ...UNIKACE a s www 2n cz 3 Configuration In this section we describe the configuration 2N Lift1 Here is what you can find in this section 3 1 2N Lift1 Programming 3 2 Table of Parameters 3 3 2N Lift1 Pro...

Page 36: ...displays a Help according to the context The default password is and you 12345 are recommended to enter a different password to protect your device against unauthorised persons Programming Procedure H...

Page 37: ...2N Lift1 saving process the values are stored immediately in the memory If you are not quite sure of how will behave after programming save 2N Lift1 the filled in form for later check Message Recordi...

Page 38: ...ne switches on depending on which party is speaking or speaking more loudly The optimum acoustic parameters are set by default and should be modified in exceptional cases only Use parameters 931 throu...

Page 39: ...he others All passwords are checked during programming i e it is forbidden to enter a password twice for one switch However you can enter one and the same password for either switch If you want to use...

Page 40: ...40 2N TELEKOMUNIKACE a s www 2n cz 3 2 Table of Parameters The table below includes all the programming functions 2N Lift1...

Page 41: ...0 9 empty 015 ALARM button memory 5 up to 16 digits 0 9 empty 016 ALARM button memory 6 up to 16 digits 0 9 empty 017 Insert specific character in ALARM memory 018 Count of automatic dialling cycles f...

Page 42: ...second p pause while programming via a PC use 2N Lift 1 Service Tool 072 Check call memory 2 up to 16 digits 0 9 empty 073 Check call memory 3 up to 16 digits 0 9 empty 074 Check call memory 4 up to...

Page 43: ...utomatic dialling type for ALARM button memory 3 1 6 1 114 Automatic dialling type for ALARM button memory 4 1 6 1 115 Automatic dialling type for ALARM button memory 5 1 6 1 116 Automatic dialling ty...

Page 44: ...is disabled 881 Switch 1 password memory 1 up to 16 digits 0 9 00 Passwords for switch 1 activation during a call 882 Switch 1 password memory 2 empty 883 Switch 1 password memory 3 empty 884 Switch...

Page 45: ...d of dialling 914 Delayed call 0 100 s 0 s Applied only if the CANCEL input is connected 915 Hang up timeout between calls 5500 9999 ms 5500 ms 916 CANCEL input inversion 0 1 0 0 contact closed or vol...

Page 46: ...ust be in the interval between parameters 952 and 953 952 Minimum ringing long gap time 100 5000 ms 1000 ms 953 Maximum ringing long gap time 500 9999 ms 6000 ms 954 Count of ringback tone periods 1 9...

Page 47: ...974 3 combine options 1 2 4 send identification by DTMF 5 message as specified in parameter 977 after confirmation according to parameter 976 6 combine options 5 2 7 confirmation tone after confirmat...

Page 48: ...if parameter 981 is set to 1 6 984 Time setting hhmm Read the current time setting and set a new value if necessary 985 Data setting RRMMDD Read the current date setting and set a new value if necess...

Page 49: ...password to avoid unintentional deletion of the 2N Lift1 memories 999 Full initialisation including service password insert service password Set the R 2N Lift1 factory values e enter the service passw...

Page 50: ...0 wire cable to the audio unit board header whose position is clearly marked on the audio unit back panel Connection Figure 2N Lift1 Programming Tool When the is connected to a PC the device is detect...

Page 51: ...gramming The programming interface provides galvanic isolation of the PC and 2N Lift1 The 10 wire interconnecting cable has no key on the side so 2N Lift1 respect the cable colours see the figure An i...

Page 52: ...s www 2n cz 4 Function and Use This section describes the basic and advanced functions of the product 2N Lift1 Here is what you can find in this section 4 1 Function Description 4 2 Service and Operat...

Page 53: ...ware All you need to operate the program is a standard PC with a 2N Lift8 VoIP account Incoming Call The control centre can also call the number 2N Lift1 2N Lift1 automatically answers the line after...

Page 54: ...ration m 2N Lift1 2N Lift1 akes dialling at any line state and only then evaluates the situation Busy tone after dialling 2N Lift1 hangs up in approx 2 seconds and dials the next number can be changed...

Page 55: ...e above listed situations In addition excessive noise in the lift cabin can adversely affect decelerate automatic dialling making it impossible to recognise the busy tone for example In general DTMF i...

Page 56: ...as a beginning of the switch control password 2N Lift1 hangs up and dials the next number Call End Outgoing Incoming The call end line hang up occurs whenever any of the below listed situations happe...

Page 57: ...ls with CAUTION the new software version Play the user message if stored in 2N Lift1 or Extend the call by 30 seconds Can be used repeatedly or Terminate the call 2N Lift1 sends its DTMF confirmation...

Page 58: ...en the communicator gets connected to the line the connection signal is heard from the speaker This tone is sent instead of confirmation in incoming calls to signal that is not configured or 2N Lift1...

Page 59: ...Kontroln vol n 2 English Attention your call is being terminated Communicator number is calling Connection confirmed Checking call 3 Slovak Pozor kon hovor Vol komunik tor slo Kontroln volanie 4 Germ...

Page 60: ...Identification If parameter 974 is set to any value and parameter 975 includes 2 3 or 6 i 2N Lift1 dentifies itself automatically with the Communicator number is calling announcement Set the lift iden...

Page 61: ...at you can find in this section 5 1 Installation and Login 5 2 Introduction to Application 5 3 Use Refer to the 2N TELEKOMUNIKACE websites official Lift1 2N download section for the latest application...

Page 62: ...ogged in user or all the PC users Now the wizard is ready to install the 2N Lift1 Service Tool Confirm the user account administration notification to the Windows system if necessary Another Start ite...

Page 63: ...that the USB port driver for is properly installed on 2N Lift1 the logging in PC If not the device will not be recognised and you will be unable to connect to it If the Incompatible NET version messa...

Page 64: ...p up menus The menu helps you connect to CU Language or disconnect from the Select the language mutation in the menu CZ and EN are available so far The Help menu provides a link to the latest manual v...

Page 65: ...2N TELEKOMUNIKACE a s www 2n cz the right hand bottom corner The other controls in the lower part may be different in different menus Let us describe all the buttons that are available in the applicat...

Page 66: ...66 2N TELEKOMUNIKACE a s www 2n cz Basic Controls...

Page 67: ...e the current table of parameters into a disk file Connect device switches the user into the Connect to device menu Back returns you to the offline configuration menu Connect connects the user to the...

Page 68: ...68 2N TELEKOMUNIKACE a s www 2n cz...

Page 69: ...Parameters Having logged in to the CU as described in the preceding subsection you get into the Parameters Basic Configuration main menu The menu includes the table of all the 2N Lift1 parameters inc...

Page 70: ...ewing favourite items A yellow to orange colour change of the Favorites button means that the favourite items are only active Click New set to overwrite the current settings with default values Click...

Page 71: ...lete filter in the used columns or using the Alt R keyboard shortcut to delete all the active filters If you do not delete the setting the filtration settings keep active even upon the 2N Lift1 logout...

Page 72: ...Set time in device helps you record a time setting of your own Click on the calendar to set the date time in hours manually You can overwrite the setting and set a different time value for a different...

Page 73: ...file type Firmware Bootloader or Voice menu Click Select to select a file and press Upgrade to make 2N Lift1 Service Tool upload the new Firmware Bootloader or Voice menu version into the audio unit D...

Page 74: ...74 2N TELEKOMUNIKACE a s www 2n cz 6 Technical Parameters This section describes the technical parameters of the product 2N Lift1 Here is what you can find in this section 6 1 Technical Parameters...

Page 75: ...5 to 60 mA Ringing impedance 2 k C 0 47 F 25 to 50 Hz Ringing detector sensitivity 10 to 20 V 25 to 50 Hz Pulse dialling 40 60 ms DTMF dialling level 9 0 2 0 2 5 dB and 11 0 dB 2 5 2 0 dB 15 to 60 mA...

Page 76: ...76 2N TELEKOMUNIKACE a s www 2n cz Other Parameters Universal model dimensions 65 130 24 mm Compact model dimensions 100 185 16 mm Working temperature range 20 to 70 C...

Page 77: ...formation This section provides supplementary information on the product 2N Lift1 Here is what you can find in this section 7 1 Troubleshooting 7 2 List of Terms and Abbreviations 7 3 Directives Laws...

Page 78: ...78 2N TELEKOMUNIKACE a s www 2n cz 7 1 Troubleshooting Nej ast ji e en probl my najdete na str nk ch faq 2n cz...

Page 79: ...and failure reports There can also be separate workplaces for various call types or just the staff mobile telephones L8 system the software can control the check alarm calls and fully 2N Lift8 admini...

Page 80: ...tive 2005 32 EC of the European Parliament and of the Council with regard to ecodesign requirements for standby and off mode electric power consumption of electrical and electronic household and offic...

Page 81: ...result of a natural disaster or any other unfavourable natural condition The manufacturer shall not be held liable for any damage of the product arising during the shipping thereof The manufacturer sh...

Page 82: ...ctric appliances and battery packs removed from them to dedicated dumpsites or containers or give them back to the dealer or manufacturer for environmental friendly disposal The dealer or manufacturer...

Page 83: ...83 2N TELEKOMUNIKACE a s www 2n cz 2N TELEKOMUNIKACE a s Mod ansk 621 143 01 Prague 4 Czech Republic Phone 420 261 301 500 Fax 420 261 301 599 E mail sales 2n cz Web www 2n cz 2136v1 3 0...

Reviews: