58

LAN Connection

2N

®

 IP 

Uni

 

is  connected  to  the  LAN  via  a  RJ-45  terminated  (connector  LAN)  UTP/STP  cable  (of 

category Cat 5e or higher). The system is equipped with the Auto-MDIX function and so both the 
straight and crossed cable versions can be used

External Power Supply Connection

2N

®

 IP 

Uni

 

can  be  fed  either  from  an  external  12  V /  2  A  DC  power  supply  or  from  the  LAN 

equipped with the PoE 802.3af supporting network elements.

External Power Supply

An  external  12  V  power  supply  is  connected  to  terminal  block  POWER.  Use  a  12  V  ±15  %  DC 
power  source  dimensioned  to  current  intake  of  2  A  at  least  (Part  No.  91341481E)  to  ensure  a 
reliable function of your device.

PoE Supply

2N

®

 IP 

Uni

 

is  compatible  with  the  PoE  802.3af  (Class  0 

– 

12,95  W)  technology  and  can  be 

supplied  directly  from  the  LAN  via  compatible  network  elements.  If  your  LAN  in  incompatible, 
insert the PoE injector, Part 

No. 

91378100E/US

between 

2N

®

 IP 

Uni

 

and the nearest network element.

Electric Lock Connection

2N

®

 IP 

Uni

 is 

equipped with active switched output 8 up to 12 V 

DC depending 

on power supply 

(PoE:  9  V;  adaptor:  power  supply  voltage  minus  2  V),  max  600 

mA, switched 

output  (terminal 

block OUT1), to which a standard electric lock or another compatible electrical appliance can be 
connected.


Caution

We recommend the use of a LAN surge protection.
We recommend the use of a shielded SSTP Ethernet cable.

Summary of Contents for IP Uni

Page 1: ...Installation manual 2N IP Uni v 2 16 www 2n com...

Page 2: ...2 2 Mechanical Installation 2 3 Electric Installation 2 3 1 Overvoltage Protection 2 4 Button Tags 2 5 Extending Module Connection 3 Function and Use 3 1 Configuration 3 2 Control 3 3 Maintenance 3 4...

Page 3: ...u can set up to three telephone numbers and time profiles for each of the buttons to increase the accessibility of the called party 2N IP Uni is equipped with an electric lock switch You can control t...

Page 4: ...mponents and Associated Products Basic Units 2N Part No 9153101 Axis Part No 01361 001 1 button control of one electric lock protective switch 2N Part No 9153102 Axis Part No 01362 001 2 buttons contr...

Page 5: ...ctograms control of one electric lock protective switch All 2N IP Uni units can be flush mounted without requiring any additional accessories Use the appropriate mounting box see below for wall surfac...

Page 6: ...Installation manual 2N IP Uni 6 58 Mounting Accessories 2N Part No 9153003 Axis Part No 01364 001 Wall mounting box Al casting Brick flush mounting box included in the delivery...

Page 7: ...ouch 2 0 black WiFi version second part no The elegant internal touch panel 2N Indoor Touch 2 0 is suitable for all 2N IP intercoms On the panel s display not only can you find out who is at the door...

Page 8: ...o 01671 001 2N Indoor Touch 2 0 white WiFi version second part no The elegant internal touch panel 2N Indoor Touch 2 0 is suitable for all 2N IP intercoms On the panel s display not only can you find...

Page 9: ...Installation manual 2N IP Uni 9 58 2N Part No 91378382W Axis Part No 01426 001 2N Indoor Touch desk stand white 2N Part No 1120101W Axis Part No 02518 001 2N IP Handset answering unit white color...

Page 10: ...ple operation HD quality video calls A display equipped extender EXP50 Part No 91378363 can be added to the phone delivery to make up to 60 speed dialings 2N Part No 1120111EU Axis Part No 02544 001 G...

Page 11: ...1202101 Mini electronic doorstrike series 5 electric opener designed for door frame installation intended for such narrow profiles as aluminum wood or PVC in particular short sheet metal front cover v...

Page 12: ...2 L Mini electronic doorstrike series 5 with momentum pin long electric opener designed for door frame installation intended for such narrow profiles as aluminum wood or PVC in particular long sheet m...

Page 13: ...naling electric opener designed for door frame installation intended for such narrow profiles as aluminum wood or PVC in particular including a door state monitoring micro switch open closed short she...

Page 14: ...long electric opener designed for door frame installation intended for such narrow profiles as aluminum wood or PVC in particular under voltage opener secured blocked at voltage interruption opener un...

Page 15: ...t metal front cover version 250 mm 16 mm width Part No 11202201 Electromechanical lock SAM 7255 72 55 self locking lock with panic function A key is necessary for door opening from the outside or an e...

Page 16: ...ent solution for emergency exits Part No 11202202 M Electromechanical lock SAM 9235 with monitoring 92 35 self locking lock with panic function A key is necessary for door opening from the outside or...

Page 17: ...or frame and the door leaf 510 mm length Part No 11202303 Cable protector FX300G Provides secure passage and protection of the supply cable between the door frame and the door leaf 440 mm length Part...

Page 18: ...connected door opens Part No 11202501 Magnetic handle P300RP fully replaces a mortise lock and handle under voltage door cannot be opened at voltage interruption magnets get disconnected door opens su...

Page 19: ...o 01403 001 PoE injetor with EU cable PoE injector with US cable For power supply of intercom via ethernet cable when PoE switch is not available Part No 91341481E Stabilised 12 V 2 A power supply nee...

Page 20: ...59010 Axis Part No 01386 001 2N Security Relay A handy add on that significantly enhances door entry security as it prevents tampering with the intercom and forced opening of the lock To be installed...

Page 21: ...ou to use existing wiring 2 wires from your original door bell or door intercom to connect any IP device You don t have to configure anything and you only need one 2N 2Wire unit at each end of the cab...

Page 22: ...op An induction loop transmits sound wirelessly from the 2N IP intercom to the earphones of people with hearing disabilities and enables them to hear and perceive sounds better 2N Part No 9159052 Axis...

Page 23: ...ease contact your local distributor of 2N products Safety Always abide by this information to prevent persons from injury Warning Always abide by this information to prevent damage to the device Cauti...

Page 24: ...IP Uni 1x Torx 10 Torx 20 double ended wrench 1x brief manual 1x mounting template 1x A5 transparent name plate foil 1x spare name plate 1x brick flush mounting box 4x 4 x 12 mm stainless steel torx...

Page 25: ...s are used for the 2N IP Uni assembly Other screws than stainless steel ones corrode soon and may aesthetically deteriorate the surrounding environment Having removed the front panel make sure that no...

Page 26: ...le tie for connection as shown Caution Before starting the mechanical installation on a selected place make sure carefully that the preparations connected with it drilling wall cutting cannot damage t...

Page 27: ...an perfect the vertical position before tightening We do not recommend you to insert the button tags now Replace the stainless steel front panel fixing it with the stainless steel screws you unscrewed...

Page 28: ...Installation manual 2N IP Uni 28 58 Hole dimensions for flush mounting Flush Mounting Plasterboard What you need Just a properly cut hole...

Page 29: ...al position before final tightening of the screws We do not recommend you to insert the button tags now Replace the stainless steel front panel fixing it with the stainless steel screws you unscrewed...

Page 30: ...eel structures entry barrier columns etc What you need Wall mounting box Part No 9153003 The 2N IP Uni Al box Part No 9153003 is designed for wall mounting especially where flush mounting is impossibl...

Page 31: ...n the bottom side c If the cables lead along the wall above the intercom level put the template to the wall reversely the bushing will be on the upper side Use an 8 mm drill to drill two holes of the...

Page 32: ...age and the electric lock PCB Connectors Description of Connectors LAN LAN connector OUT1 Active switched output RELAY1 Relay NO NC contacts Used for connection of non critical devices only lights e g...

Page 33: ...current intake of 2 A at least Part No 91341481E to ensure a reliable function of your device PoE Supply 2N IP Uni is compatible with the PoE 802 3af Class 0 12 95 W technology and can be supplied di...

Page 34: ...ion manual 2N IP Uni 34 58 Tip Output wiring diagram for Relay terminals Wiring diagram for the controlled device s electric circuit closing Wiring diagram for the controlled device s electric circuit...

Page 35: ...ining a coil such as a relay or an electromagnetic lock it is necessary to protect the intercom against voltage peak while switching off the induction load For this way of protection we recommend a di...

Page 36: ...T button Push the button for 30 s to reset the factory default values deleting all the data stored in the device Device Restarting Press the RESET button shortly 1 s to restart the system without chan...

Page 37: ...ilding on its outer wall or roof Overvoltage may damage devices connected to these wires and installed inside the building as well Therefore we recommend that additional surge protectors be installed...

Page 38: ...il and insert the tags in the name plates template for printing is available in section Downloads Every name plate includes a piece of foil which can be written over manually using a waterproof perman...

Page 39: ...ressed when moved by approx 0 5 mm the tag is too thick or thin Make sure that the button clicks when you press it on either end 2 5 Extending Module Connection 2N IP Uni allows to connect following e...

Page 40: ...ide the area to be secured typically behind the door The device is powered and controlled via this two wire cable and so can be added to an existing installation Thanks to its compact dimensions the d...

Page 41: ...y Reset button for 5 seconds to put the device in the programming mode both the red and green LEDs are blinking Activate the intercom switch using the keypad telephone etc The first code sent from the...

Page 42: ...er adapter is part of sound system installations for hearing impaired persons that are equipped with a special hearing aid capable of receiving reproduced sound via a magnetic field receiver The syste...

Page 43: ...e screws with the blanks supplied Use the supplied connectors to connect the amplifier to the intercom and power supply The A connector is connected to the amplifier four wire cable Insert a special i...

Page 44: ...allel with 0 3 H Output current 1 load 2 2 Arms sine wave Full power output 1 6 Arms pink noise Output current 8 load 730 mArms sine wave signal Half power output 520 mArms pink noise signal Output sh...

Page 45: ...ing the Admin user name and 2n password You have to know the IP address of your device to log in to the integrated web server By default 2N IP Uni is switched into the dynamic IP address mode i e it o...

Page 46: ...power supply Wait for the second sound signal Press the quick dial button 5 times 2N IP Uni will read its IP address If the address is 0 0 0 0 it means that the intercom has not obtained the IP addre...

Page 47: ...For devices with FW versions 2 33 and lower wait until the device is automatically restarted After restart the static IP address mode is switched into the dynamic IP address and vice versa Simultaneou...

Page 48: ...number of the called subscriber or may be assigned no function 3 3 Maintenance Cleaning If used frequenly the device surface gets dirty To clean it use a piece of soft cloth moistened with clean wate...

Page 49: ...was designed and manufactured for in compliance herewith The manufacturer reserves the right to modify the product in order to improve its qualities 2N IP Uni contains no environmentally harmful compo...

Page 50: ...able name tags Button count 1 or 2 Audio Microphone 1 integrated microphone Amplifier 1 W class D Loudspeaker 1 W Sound pressure level SPL max 77 5 dB for 1 kHz distance 1 m Volume control Adjustable...

Page 51: ...n power supply PoE 9 V adaptor power supply voltage minus 2 V max 600 mA Mechanical properties Cover ABS plastic high quality stainless steel Working temperature 40 C to 55 C Working relative humidity...

Page 52: ...Installation manual 2N IP Uni 52 58 4 1 General drawings Surface mounting Flush mounting Plasterboard mounting Flush mounting with box...

Page 53: ...CC This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules NOTE These limits are designed to provide reasonable protection...

Page 54: ...54 58 Consult the dealer or an experienced radio TV technician for help Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s autho...

Page 55: ...rmined by the manufacturer as incompatible with certain versions of other products and only in conformity with the manufacturer s instructions guidelines or recommendations and in conjunction with sui...

Page 56: ...e as well as provisions of technical standards on electric installations have to be obeyed The manufacturer shall not be liable and responsible for damage or destruction of the product or damage incur...

Page 57: ...r or manufacturer shall take the product back free of charge and without requiring another purchase Make sure that the devices to be disposed of are complete Do not throw battery packs into fire Batte...

Page 58: ...Installation manual 2N IP Uni 58 58...

Reviews: