24
8.3.6. Initialization
All programmable parameters are arranged in tables according to their functions. You
can initialize either all parameters at once or one table of parameters.
For initialization via a telephone line fill in the function number according to the type
of initialization and enter the service password as the parameter.
Telephone line initialization
Function
No.: 91
Initialization of all parameters necessary for the telephone line function.
Call table initialization
Function
No.: 92
Initialization of all parameters related to dialed telephone number.
Initialization of GSM & SIM
Function
No.: 94
Initialization of all parameters related to the GSM network and SIM card (except
for the PIN code).
SMS input initialization
Function
No.: 93
Initialization of all parameters for SMS sending upon SMS input activation.
Global initialization
Function
No.: 99
Initialization of all EasyGate parameters including the PIN and service password.
8.3.7. Security Parameters
PIN - value
Function No.:
40
Fill in the
PIN value for automatic PIN entering upon EasyGate power up. It is
applied only if the SIM card is PIN secured. If the given PIN fails to match the
SIM, it is deleted automatically. If entered via a telephone line upon EasyGate
start, the PIN is stored automatically.
Setting options:
0, 4-8 characters (0-9)
Upon full initialization: blank
Service
password
Function No.:
90
Fill the service password for programming via a telephone line. Some parameters
can be programmed by DTMF dialing and so the access to programming must be
password-protected.
Setting options:
4-8 characters (0-9)
Upon full initialization: 12345