18
8.3. Parameter Tables
All programmable parameters are listed in this section. Each parameter is
accompanied with the unit used, function number (if available) for programming via a
telephone line, description of EasyGate's behavior, setting options, setting step and
default (initialization) value.
8.3.1. Telephone Line Parameters
Type
of
dialing
Function No.:
-
Select the dialing type to be received by EasyGate from the PBX or telephone
set. EasyGate accepts only the selected type of dialing, ignoring the others.
Setting options:
DTMF
-EasyGate receives tone dialing only.
Pulse
-EasyGate receives pulse dialing only
Default setting: DTMF
Time to dial
[s] Function
No.: -
Timeout during which EasyGate waits for further digits to be dialed. It starts to
establish connection when this timeout passes.
Setting options: 1-15 s
Setting step:
1 s
Default setting: 5 s
Tone after disconnection
Function
No.: -
If the remote subscriber hangs up first, the EasyGate subscriber can hear the
tone selected here.
Setting options:
Busy
-EasyGate transmits the busy tone upon call end.
Permanent
-EasyGate
transmits the permanent tone upon call end.
Default setting: Busy tone
Minimal On Hook
[ms]
Function
No.: -
The minimum line current discontinuation that EasyGate evaluates as hang-up.
Setting options: 100-1500 ms
Setting step:
100 ms
Default setting: 500 ms
Beep after dialing end
Function
No.: -
Select a beep to signal the end of dialing (beginning of outgoing call
establishing).
Setting options: YES/NO
Default setting: YES
BabyCall number
Function
No.: -
A number to be dialed for the automatic call function. If this item is blank, the
function is disabled.
Setting options: 0-15 characters (0-9,*,#,+)
Default setting: blank