6.3.5. Programming Error
•
If you make a mistake while entering a number (no matter whether a parameter
number or a value) and find it before you press
, you can cancel the whole
programming step using the
character.
•
If the GSM Gateway transmits a rejection signal
, you have to re-enter the
parameter number even if the value was incorrect.
•
If, while programming more parameters at the same time (table line) using the above
mentioned procedure, you make a mistake in the third parameter, e.g., and the GSM
Gateway transmits a rejection signal
, all correctly entered parameters have
already been stored and you need not re-enter them. You can either re-enter the whole
line or enter the remaining parameters individually.
•
If you program and the GSM Gateway stores a value that you do not want, you can
re-enter the value correctly, of course, i.e. re-enter the parameter number, etc.
6.3.6. Erasing of parameters
•
To erase parameter, enter its number,
and once again
.
•
Only parameters, which can be empty (see Parameter Tables, chapter 7), can be erased this
way. In case of parameter, which cannot be empty (defined range, e.g. receiving volume and
the like), GSM Gateway transmits a rejection signal
.
•
Erasing parameters in the Call Sorting Table: If you will erase some prefix, i.e. the first
parameter on the row, all parameters on this row will be erased (or initialised). If you will
enter row number (e.g. 501) or number of first parameter (e.g. 5011), it has the same effect.
But, if you will enter number of another parameter (e.g. 5010), only this parameter will be
erased.
6.3.7. Programming End
Hang up to terminate programming. After the programming end make sure that the GSM
Gateway works as you want it to. Store the completed programming form of configuration
file safe.
6.3.8. Signalling During Telephone-Based Programming
Signal Name Meaning
Confirmation
•
After valid service password
•
After valid parameter No.
Rejection
(error)
•
After invalid parameter No.
•
After invalid parameter value
•
After cancelling of anything by
Storing
•
Value is valid and stored
Storing 2
•
Value is valid and stored, next parameter may be entered