![2N 9135110E Installation Manual Download Page 44](http://html1.mh-extra.com/html/2n/9135110e/9135110e_installation-manual_3044422044.webp)
Installation manual 2N® Analog Vario
44
/
77
•
•
•
Parameter
(function)
Parameter Name
Range
Default
Note
811
Enter up to 10
switch
1
passwords
up to 16
digits
00
Passwords 00 and 11
cannot be entered
from the keypad!
Up to 10 switch
passwords
Delete passwords
using functions 812,
822
821
Enter up to 10
switch
2
passwords
11
812
Delete valid switch
1
passwords
Valid pass-
word
Deletes individual valid
switch 1 passwords.
822
Delete valid switch
2
passwords
Deletes individual valid
switch 2 passwords.
813
Switch
1
closing
time
0–9 s
5 s
0 = switch disabled
823
Switch
2
closing
time
0–9 s
5 s
0 = switch disabled
824
Switch
2
delay
0-25 s
0
0 = switch 2 is not
synchronised with switch
1
901
Dialling type
0–1
0 = tone
1 = pulse 40/60
902
Dialling timeout
after pick-up
5–99
8 = 0,8 s
Range of 0,5 s – 9,9 s
903
DTMF transmitting
level
0–12
6
1 step = 1 dB
Summary of Contents for 9135110E
Page 1: ...Installation manual 2N Analog Vario v 1 6 www 2n com ...
Page 5: ...Installation manual 2N Analog Vario 5 77 Part No 9135130E Main unit 3 buttons ...
Page 38: ...Installation manual 2N Analog Vario 38 77 ...
Page 39: ...Installation manual 2N Analog Vario 39 77 ...
Page 71: ...Installation manual 2N Analog Vario 71 77 3 6 Downloads Templates Nametags ...
Page 74: ...Installation manual 2N Analog Vario 74 77 4 1 Obecné výkresy Surface mounting Flush mounting ...