background image

 

 

 

2N

 ®

 APS 

MINI 

E

NTRYCOM

 

SET 

Order No. 91341611WE 

 
 

 

 

 

 

 
 

User and service manual 

 

 

Version 2.1 

 

Summary of Contents for 91341611WE

Page 1: ...2N APS MINI ENTRYCOM SET Order No 91341611WE User and service manual Version 2 1 ...

Page 2: ...WE EntryCom Set 9134162WE Standalone reader module 9134167WE Reader module with attendance keypad 91341612WE Built in reader module for EntryCom 91341631E Converter RS485 Ethernet 9134164E PC mini reader 9134165E Chip card 9134166E Chip key fob ...

Page 3: ...ut by the reading module autonomously without the need to be connected to the PC After connecting to the PC the system offers more functions thanks to online status monitoring and to archiving of events from the connected reading modules The reading module integrating all circuits necessary for one reading place and one door is the basic hardware element of the APS mini access system Regimes of op...

Page 4: ...ccess cards in the memory 748 Inputs 2x logical non potential Output for door lock 1x relay switch contact 2 A 24 V Alarm output Transistor output 5 V 5 mA Protective contact tamper Opto electric Typical reading distance 2 cm in panel Communication channel RS485 galvanic non separated Alternative data output WIEGAND configurable Signalization Piezzo buzzer 3x LED on the board Working temperature 1...

Page 5: ...objects absorb electromagnetic field and may disturb the antenna of the module also in this case we recommend practical test It is recommended to install the chip card reader indoor on a wall together with the door communicator and reader s antenna Installing the reader indoors will provide protection against climatic conditions of the outside environment and aggression of persons trying to break ...

Page 6: ...ltage use contacts C and NO For locks that open when voltage disappears while under voltage they are locked use contacts C and NC Lead voltage through these contacts from the power supply to the door lock If there is a contact on the door which is switched when the door is closed lead the contacts to the clips of input 1 Contact for monitoring the status of the door input 1 is taken into considera...

Page 7: ...e end of the data bus last module on the line must contain terminal resistor jumper inserted on the contacts of the J5 connection When using certain converters dividers and repeaters on the RS485 data bus it might be necessary to insert jumpers on the connections J4 and J6 which define resting state on the bus When using a converter supplied by the manufacturer GNOME485 it is not necessary to inst...

Page 8: ... proper connection of the module Area for setting the HW address Area with control elements for setting the general properties of the module Indicators are located in the individual parts of the status bar from the left Indicator of the state of communication with the module red color indicates error in communication flawless communication is indicated by green color Indicator of the process of sa...

Page 9: ... to the normal operational regime by itself Erasing cards from the memory Step 1 Step 2 Step 3 After having read the programming card for erasing the reader is set to programming regime Read cards that are to be rid of the access rights in the entry place in question After c 15 s after the last card the reader will go to the normal operational regime by itself Erasing all programmed cards Step 1 S...

Page 10: ...2N TELEKOMUNIKACE a s Mod anská 621 143 01 Praha 4 Czech Republic tel 420 261 301 111 fax 420 261 301 999 e mail sales 2n cz www 2n cz 2008 2N TELEKOMUNIKACE a s Praha OV 1350 v 2 1 ...