4
1.
ATEUS
®
- STARGATE Description - General Design
1.1. 19” Subrack
1.1.1. Basic Dimensions
The system is integrated in a 19’’ subrack of the height of 3U and depth of 360mm. The
front side is open, equipped with guides for plug-in boards with front panels – the panel
including a mains switch is part of the subrack. In case not all GSM boards are plugged in, the
free section of the front side must be covered with a fixed panel (fixed panels).
The back side is completely covered with a panel with a built-in ventilator, which is
switched by a thermostat for higher reliability and longer life. An AC mains supply unit is located
in front of the ventilator. The bottom and upper sides are covered with perforated sheet, the
assembly flanges are provided with handrails.
The system bus is designed as a printed circuit board (PCB) with DIN connectors and
fitted to the inner subrack carrier profiles.
1.1.2. Front Side Division
The subrack width is divided into an 8HP-wide mains panel and 19 4HP-wide modules in
the following sequence (from right to left):
•
8HP fixed panel with a mains switch, fuse and mains cable socket;
•
4HP CPU board (must be included in any case);
•
4HP AUX board (must be included in any case);
•
4HP PRI boards (must be included in any case);
•
64HP GSM boards, i.e. 16 times 4HP (1 to 16 boards may be included).
1.2. Available Software for STARGATE
STARGATE program
- tool to configure and control STARGATE
STARGATE Accounter - tool for automatic download of cdr info via IP connection
STARGATE Wizard*
- utility for easy basic parameter setting
CDR converter
- utility for cdr information conversion from text format into CSV format
SIM SN reader
- utility for reading of IMSI, SDID numbers of active SIM cards
1.3. Power Supply
1.3.1. Description
The system uses an industrial mains supply unit with primary voltage of 100-240VAC
50/60Hz and secondary voltage of 5V/30A with natural cooling and an auxiliary external
ventilator, which is switched on automatically whenever the power supply temperature exceeds
70°C. The supply is designed with a 30% reserve even under the maximum load.
Summary of Contents for ATEUS STARGATE
Page 1: ...ATEUS STARGATE User s Manual Version 5 1...
Page 2: ......
Page 21: ...19 Schematics block diagram...