General Functions Overview 
 
1. INT/EXT:  

Toggle that switches between the internal clock and an external clock.

 

 
If the toggle is in the left position, Rnd will be clocked at the rate of its internal clock 
 
If the toggle is in the right position, Rnd will generate a new random voltage upon 
receiving a gate or trigger signal at the 

CLOCK INPUT

.  

 
 
2. CLOCK INPUT: 

If the 

INT/EXT

 toggle is in the left position, high voltage inserted into 

CLOCK INPUT

 

will freeze the random voltage emitting from 

RND OUT.

 

 

External clock input when the 

INT/EXT

 toggle is in the right position. 

 

Threshold: 2.5V 

 

 

3. RATE: 

Internal clock rate control that changes the speed at which random voltage is 
generated when the 

INT/EXT

 toggle is in the left position 

 
Probability control of random gate signals when the INT/EXT toggle is in the right 
position 
 

INT Clock Mode 

If the knob is far left, the internal clock rate will be as slow as possible.  
 
If the knob is far right, the internal clock rate will be as fast as possible.  
 

EXT Clock mode 

If the knob is far left, the probability of the random gate signals will be as low as 
possible 
 
If the knob is far right, the probability of the random gate signals will be as high as 
possible.  

 
 
 

Summary of Contents for Rnd

Page 1: ...Rnd Random Voltage Generator ...

Page 2: ... attenuator control provides fine tuning of the random voltage This allows for a musically useful range to be defined In addition random gates are emitted from the gate output with an associated probability control while externally clocked Great for modulation and chaotic rhythmic events Rnd is a universal solution for adding unpredictability to your system ...

Page 3: ...3 Table of Contents Installation Specifications 4 Rnd 5 General Functions Overview 6 ...

Page 4: ...tor into the power distribution board of your case keeping in mind that the red band corresponds to negative 12 volts In most systems the negative 12 volt supply line is at the bottom The power cable should be connected to the Rnd with the red band facing the bottom of the module Specifications Format 2 HP Eurorack module Depth 34mm Skiff Friendly Max Current 12V 40mA 12V 16mA ...

Page 5: ...5 1 2 3 4 5 6 7 8 ...

Page 6: ...External clock input when the INT EXT toggle is in the right position Threshold 2 5V 3 RATE Internal clock rate control that changes the speed at which random voltage is generated when the INT EXT toggle is in the left position Probability control of random gate signals when the INT EXT toggle is in the right position INT Clock Mode If the knob is far left the internal clock rate will be as slow a...

Page 7: ... of the internal clock when the INT EXT toggle is in the left position LED that illuminates when a random gate signal is emitted from the GATE OUT when the INT EXT toggle is in the right position 7 GATE OUT Output that will emit gate signals at the rate of the internal clock when the INT EXT toggle is in the left position Output that will emit random gate signals when the INT EXT toggle is in the ...

Reviews: