-8-
LOCK
Take off the Jumper
POWER
SUPPLY
LOCK
Take off the Jumper
POWER
SUPPLY
LOCK
BUS
PL
S1+ S2+ S-
BUS
PL
S1+ S2+ S-
connect one lock
connect two locks
5.2.3 Unlock parameter setting(set on monitor)
1.Touch
item on main
menu page.
2.Touch the screen anywhere and
hold for 2s.
3.Touch Installer setup item
4.A digital keypad and setting
instructions will be shown.
Manual
Monitor
Monitor
Memory
Playback
Album
User Setup
09/30/2010 Thu.16:41
Close
Intercom
Multimedia
H/W : --- a1.3
S/W: V17.11.418.00
Local addr: ---
Unlock timing: ---
Video standard: -
UI-CODE: ---
MCM-VER.: ---
Updated: ---
Home
Installer
setup
Caliber
TouchScreen
Code Number:[----]
[0010]#:Remove all remote control
[0011]#:Add remote control
[8000]#:Set as master unit 0
[8001]#:Set as slaver unit 1
[8002]#:Set as slaver unit 2
[8003]#:Set as slaver unit 3
[8004]#:Set as guard unit
[8005]#:Set as not guard unit
[8006]#:Panel on as slaver unit called
[8007]#:Panel off as slaver unit called
[8008]#:Date format:MM/DD/YYYY
[8009]#:Date format:DD/MM/YYYY
[8010]#:Set lock mode to 0
[8011]#:Set lock mode to 1
[8021]~[8029]
#Set the lock time of 1~9s
Multi language settings:
---
1
4
7
8
0
9
6
5
2
3
Cancel
Installation settings:
Note:
1.must connect correctly before setting.
2.the parameter will be saved in door station automatically,so you need only
set on one monitor.
3.the above diagram is fit for icon menu series monitors only, to text menu se
-
ries monitors,please refer to the corresponding user manual.