background image

DT594 USER MANUAL(EN)

2-Wire Video Intercom System

Read this manual carefully before using the product, and keep it well for future use.

Summary of Contents for DT594

Page 1: ...DT594 USER MANUAL EN 2 Wire Video Intercom System Read this manual carefully before using the product and keep it well for future use ...

Page 2: ...r protection against water One or two touch sensor call button can be se lected The large name label with white backlight is covered by a fully secured and flameproof glass plate Parts and Function 178 92 35 6 22 Camera Lens Night View LED Speaker Nameplate Call Button Microphone Rainy Cover 1 2 ON Lock Control Jumper Doorstation Code DIP T R T R 1 2 3 1 2 ON BUS Blue Green S2 Red PL White S1 Yell...

Page 3: ...ort To connect the bus line and the electronic locks BUS Blue Green Connect to the bus line non polarity PL White External lock power input connect to the power positive power S1 Yellow The first lock power output S2 Red The second lock power output S Black Lock power output Door Station Mounting 1 Mounting with rainy cover Mounting without rainy cover 2 3 1 2 3 ...

Page 4: ... of the camera then fix the screw The location of the unit should keep away from snow rain and intensity light Installation Steps Installation height for door station usually is 145 160cm 1 Use screws to fix the back panel and rainy cover if mounting with rainy cover to the wall after connect the cable correctly 2 Attach the front panel to the back panel then use the screw to fix it ...

Page 5: ... 1 2 ON 1 Camera DIP on off off ID 00 ID 10 ID 01 ID 11 2 Camera 3 Camera 4 Camera DBC 4S A B C D OFF ON Impedance switch AC PC6 Multi Monitors Connection monitor monitor monitor monitor Code 0 DIP 6 off 1 2 3 4 5 6 ON Code 1 DIP 6 off 1 2 3 4 5 6 ON AC PC6 Code 14 DIP 6 off 1 2 3 4 5 6 ON Code 15 DIP 6 on 1 2 3 4 5 6 ON 1 2 ON ID 00 ...

Page 6: ... Code 0 DIP 6 on Code 15 DIP 6 on Code 13 DIP 6 on Code 14 DIP 6 on Code 12 DIP 6 on OFF ON OFF ON monitor monitor monitor monitor monitor monitor monitor monitor DBC 4S A B C D DBC 4S A B C D Impedance switch Impedance switch DIP on off off DIP on off off AC PC6 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 ON ID 00 ...

Page 7: ... Button EB 4 The Unlock Mode Parameter of Monitor must be set to 0 by default EB LOCK LOCK 2nd 1ST 2nd EB 1ST Jumper position in Connect two locks 2 3 1 2 3 BUS PL S1 S2 S EB LOCK BUS PL S1 S2 S Jumper position in Connect one lock 2 3 1 2 3 Door Lock Controlled with Dry Contact Note 1 The external power supply must be used according to the lock 2 Setup the Unlock Mode of Monitor for different lock...

Page 8: ...een Code Number 0010 Remove all remote control 0011 Add remote control 8000 Set as master unit 0 8001 Set as slaver unit 1 8002 Set as slaver unit 2 8003 Set as slaver unit 3 8004 Set as guard unit 8005 Set as not guard unit 8006 Panel on as slaver unit called 8007 Panel off as slaver unit called 8008 Date format MM DD YYYY 8009 Date format DD MM YYYY 8010 Set lock mode to 0 8011 Set lock mode to ...

Page 9: ...which have to be set to ON if match the impedance otherwise set to OFF Bit 1 Bit 5 are used to set user code If the door station with one call button the user code should be set to 0 15 If the door station with two call buttons the user code should be set to 0 31 Please refer to the following settings Door station DIP setting Indoor monitor DIP setting Bit state Descriptions Default setting ID 0 0...

Page 10: ... 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON code 11 code 12 code 13 code 14 code 15 code 16 code 17 code 18 code 19 code 20 code 21 code 22 code 23 code 24 code 25 code 26 code 27 code 28 code 29 code 30 code 31 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 ...

Page 11: ...he farest monitor B A C DBC 4S monitor monitor monitor with two or four monitors AC PC6 When Monitor quantity 20 Cable Usage A B C Twisted cable 2x0 75 mm2 60 60 30 Twisted cable 2x1 mm2 80 80 40 When Monitor quantity 20 Cable Usage A B C Twisted cable 2x1 mm2 70 30 20 Twisted cable 2x1 5 mm2 70 50 30 Note If the monitor has been specified the distance refer to the parameter ...

Page 12: ...188 H 110 W 34 D mm Precautions Please clean the unit with soft cotton cloth don t use the organic impregnant or chemical clean agent If necessary please use a little pure water or dilute soap water to clean the dust The unit is weather resistant However do not spray high pressure water on access control keypad directly Excessive moisture may cause problems with the unit You must use the right ada...