background image

Unit Mounting

The location of outdoor station should keep away from snow,rain,and intensity light.

Accessory contents:

Accessories include a screwdriver T20, one M4X10 screw,  two PA4X25 screws,three PA3x25 

screws,three PM3x12 screws,and five screw stoppers Φ6X30.

Installation steps:

Installation height for door station usually is 145~160cm.

1. Use screws to fix the back panel and rainy cover to the wall after connect the cable correctly.

2. Attach the front panel to the back panel, then use the screw to fix it.

Wiring and Connection

Basic one-to-one connection

1

2
3

4

7

5

6

M4*10

PM3*12

1

2

3

-

+

Monitor

Bus   PL S2+ S1+ S1-

BUS(Blue&Green);

   S2+(Red);   PL(White);   S1+(Yellow);   S1-(Black);

AC~

PC6

1 2 3

ON

1  2  3

1 2 3

ON

1  2  3

BUS(Blue&Green)

S2+(Red)

PL(White)
S1+(Yellow)

S1-(Black)

4P

terminal

DIP

PROG

SPK adjust

Lock Control

Jumper

CALL button

please refer to DT-CAM user instructions in details.

PL(White): external lock power input, connect to the power positive(power +).

S1+(Yellow): lock power(+) output.

S1-(Black): lock power(-) output.

Parts and Function

Speaker

Unlock Indicator

Talk Indicator

Front Panel

Call Button

Microphone

1

2

3

4

5

6

Terminal Description

The audio door station is designed for the CDV 2Easy 2-wire system. The 17-D is made of 
zinc alloy for protection against vandalism including the call button  featuring  a  blue  
backlight  for  auxiliary  illumination.  The  door  unlock and speech LED indicator show 
visual verification of operation. The rain cover provides  protection adverse weather.

Connection 

Cable

 BUS(Blue&Green): connect to the bus line, no polarity.
 S2+(Red): the S2+ connect with S1- to activate the relay of ERL to extend a  camera
                 of DT-CAM, please refer to DT-CAM user instructions in details. 

◆ 

Lock Control Jumper:

 For selection of lock type. Please refer to Electric Lock Connection: Pg7.

◆ 

DIP switch:

 

to set ID code for door station, total 4 door stations can be supported. Please refer to    

    DIP Switch Settings.

◆ 

SPK adjust:

 to adjust the talk volume.

◆ 

PROG button:

 reserved.

◆ 

CALL button:

 

press to call the user.

◆ 

4P terminal:

 to update software via specified programmer.

◆ 

Connection cable:

 to connect the bus line and the electronic locks.

7

Rain Cover

-

1

-

Summary of Contents for 17-D

Page 1: ...2 Wire Intercom System Read this manual carefully before using the product and keep safe for future use CDV17DS INSTALLATION MANUAL EN ...

Page 2: ... show visual verification of operation The rain cover provides protection adverse weather Connection Cable BUS Blue Green connect to the bus line no polarity S2 Red the S2 connect with S1 to activate the relay of ERL to extend a camera of DT CAM please refer to DT CAM user instructions in details Lock Control Jumper For selection of lock type Please refer to Electric Lock Connection Pg7 DIP switch...

Page 3: ...on of outdoor station should kept away from direct snow rain and intense light Accessory contents Accessories include a screwdriver T20 one M4x10 screw two PA4x25 screws three PA3x25 screws three PM3x12 screws and five screw stoppers 6x30 Installation steps Installation height for door station usually is 145 160cm 1 Use screws to fix the back panel and rain cover to the wall connect the cable corr...

Page 4: ...s PL S2 S1 S1 Bus PL S2 S1 S1 1 2 3 ON ID 00 Code 0 DIP 6 off 1 2 3 4 5 6 ON Code 1 DIP 6 off 1 2 3 4 5 6 ON AC PC6 AC PC6 Code 14 DIP 6 off 1 2 3 4 5 6 ON Code 15 DIP 6 on 1 2 3 4 5 6 ON Mult Door Staton Connecton BUS Blue Green S2 Red PL White S1 Yellow S1 Black Multi Monitors ConnectionBasic IN OUT wiring mode Audio Handset Audio Handset Audio Handset Audio Handset Audio Handset 3 ...

Page 5: ...ode 14 DIP 6 on Code 12 DIP 6 on OFF ON OFF ON DBC 4S A B C D DBC 4S A B C D Impedance switch Impedance switch DIP on off off DIP on off off 1 2 3 ON ID 00 AC PC6 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON With DBC 4S Wiring Mode Audio Handset Audio Handset Audio Handset Audio Handset Audio Handset Audio Handset Audio Handset Audio Handset 4 ...

Page 6: ... Note 1 Electronic lock of Power on to unlock fail secure type should be used 2 The door lock is limited to 12V and holding current must be less than 250mA 3 The door lock control is not timed from Exit Button EB 4 The Unlock Mode Parameter of Monitor must be set to 0 by default Note 1 An external power supply must be used depending on they type of lock used 2 The jumper must be taken off before c...

Page 7: ... Set DIP 1 OFF DIP 2 ON 2 Press the PROG fig 1 button and hold for 3 secs blue LED on to activate the setup option 3 Press the PROG fig 1 button and hold for the number of seconds required indicted by beeps and red LED The time between pressing and releasing the PRGO button is the unlock time Note DIP 1 and DIP 2 should reset to the corresponding address code after setting the above Fig 1 1 2 3 Pr...

Page 8: ...ch please refer to the following Total 3 bits can be configured bit 1 and bit 2 are used to assign ID code for door station bit 3 is used to match the video impedance The switches can be modified either before or after installation Note for video impedance EOL set the bit 3 on Indoor monitor DIP setting There are 6 bits in total The DIP switches are used to configure the user address for Monitors ...

Page 9: ... Working status 200mA Lock Power Supply 12Vdc 300mA Internal Power Working Temperature 10ºC 45ºC Wiring 2 wires non polarity Dimension 137 H x49 W x28 D mm Please clean the unit with soft cotton cloth do not use a chemical cleaning agent If necessary please use a little pure water or dilute soap water to clean the dust The unit is weather resistant However do not spray high pressure water on acces...

Page 10: ...0 30 20 70 50 30 Twisted cable 2x1 5 mm2 B A C DBC 4S AC PC6 Cable Requirements The maximum wiring distance is limited in the 2Easy system Using different cables can also affect the maximum distance achievable The furthest monitor with two to four monitors Note If the monitor has been specified the distance refer to the parameter Audio Handset Audio Handset Audio Handset 9 ...

Page 11: ......

Page 12: ...Right to interpret and copyright of this manual are preserved The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved DT ENG 595A V1 P120924 ...