background image

5

. Use & Care of Housing: 

 

5.1

 Pre Dive Function Check. 

Just before entering the water, make a habit of reviewing that you have carried out the 

proper steps to close the housing. and the pressure release plug screwed home. Make a 

visual check of the O-ring seal. It is also useful to switch on the camera, and check that 

controls e.g. on/off, zoom, shutter functions operate normally. 

 

Check housing is closed. 

 

Close pressure release plug 

 

Check battery and memory card status on the LCD display. 

 

Check control knob and zoom function. 

If there is a large change of temperature and the housing is not opened for maintenance 

between dives, it is recommended to equalize the possible pressure difference between the 

inside of the housing and the ambient by opening the pressure release plug and close it 

firmly subsequently. Always avoid submerging the housing in hot water for a prolonged time 

or a cleansing tank where the water may be heated up by the sun. 

 

5.2

 General Operation. 

The control levers and push buttons consist of internal double O-ring seals on a stainless steel 

shaft. This arrangement is very reliable, however as a precaution, when operating the controls, avoid 

excessively rapid movements, as this may distort the O-ring. Also please allow for the fact that the camera 

takes a few seconds to power on. If the camera dose not appear to respond to a control action, make sure 

that no other controls are pressing on the camera, i.e. locking out further actions. Wear the wrist strap; it 

is easy to inadvertently let go of the housing, especially if you are distracted. 

 

5.3

 Cleaning & Storage. 

The body & lid of the housing are made of polycarbonate. Polycarbonate was selected for its 

outstanding strength stiffness, hardness and toughness. As well as its crystal clear transparency and high 

gloss surface. It has good resistance to weathering, although long term exposure to sunlight should be 

avoided. Normal operating temperature range is 3°C to 36°C (Storage temperature: -10°C to 50°C) It is 

good practice to rinse off your housing with fresh water after every dive. Avoid exposure to fine sand. 

After a series of 10 or more dives, e.g. after a dive holiday, it is recommended to immerse the housing for 

2-3 hours in warm water to dissolve any salt deposits that may have built up. No chemical cleaners should 

be used. Mild detergents e.g. shampoo and soap based cleaners are permitted. 

 

Important !!! 

Some household chemicals may harm Polycarbonate; the 

housing should never be exposed to the following classes of chemicals: 

benzene, toluene, xylene, chlorinated hydrocarbons, methanol, any other solvents, 

strong acids and bases. 

For long term storage please remove the main o-ring from body. 

 

5.4

 Transportation. 

When transporting by air, please ensure the housing is not sealed, to allow the air pressure to 

equalize. Either remove the O -ring (recommended), or open the pressure release port (a spacer is 

provided to keep the pressure plug in the open position, please make sure there is no bending of the plug 

while open). Please protect the housing during transportation. It is recommended to remove the handle, 

and shutter extension, and wrap the camera in foam or bubble wrap. 

 

Summary of Contents for 400D

Page 1: ... clear polycarbonate allows for visual inspection of camera condition and the O ring seal 10 BAR Housings are designed for the ever increasing variety of models of digital still and video cameras Advanced computer aided design and CNC manufacturing technologies ensure precise dimensions Each housing body is first injection molded and then machined to configure to individual camera model A range of...

Page 2: ...pproximately neutral in salt water Features Visible main O ring for final pre dive check Double O ring design on all controls Bulkhead and hot shoe plug for External 580 EX e TTL strobe Standard Zoom Port18 55mm Lens Accessories 400D Opening key Lever Silicone O ring grease Spare main O ring Carrying bag Cleaning Kit Optional accessories Semi Dome Port for 10 22mm Lens 580 EX e TTL Flashlight Hous...

Page 3: ...on off 3 Menu 4 Jump 5 Playback 6 Erase 7 Viewfinder eyepiece 8 A E Compensation 9 Drive Mode 10 AE FE Lock 11 AF Point Selection 12 13 14 15 Cross Key 16 Setting 17 Shutter 18 Main Dial 19 Mode Dail Power on off 20 Flashlight syn bulkhead 21 Zoom control dial ...

Page 4: ...irt salt etc and is not required for watertight integrity If this O ring should become detached it can simply be pushed back in place Fig 1 Open Housing Procedure 4 3 Opening levers After unscrewing and pulling out the pressure release plug the lid can be opened To overcome the friction of opening use lever Fig 2 to push against the lid with a cam action Be sure they are inserted all the way flat ...

Page 5: ...idedyou re your guidance in using and maintaining the O ring seal 4 5 Maintaining the O ring Seal If the main body to lid O ring is not installed install the O ring before diving This is the only user serviceable O ring Its care and maintenance is critical to the watertight integrity of the housing The O ring should be replaced at the service interval see section on service If the O ring is contam...

Page 6: ...MEDIATELY A spare O ring is supplied with your housing or a replacement O ring can be obtained from 10 BAR If the O ring is contaminated or suspected of being contaminated clean it with a cotton cloth that is free of all chemicals or contamination After cleaning inspect the O ring again Once the O ring has been inspected and verified fit for use apply a SMALL amount of Silicone grease to the O rin...

Page 7: ...ile closing otherwise the air cannot escape Squeeze the lid closed all the way with the hissing of expelled air Screw home CLOCKWISE the pressure release plug Fig 9 There is no need to excessively tighten this plug The seal is made by internal O rings The O ring on the underside of the plug is just to keep out dirt ...

Page 8: ...t 0 5 to 1mm in width should be visible where the O ring is in contact with the lid Follow this line all the way round the edge of the seal as a final check that the seal is good The housing is now ready for the dive Important Before diving make sure the pressure release plug is pushed back inside and then screwed home do not over tighten this plug finger tight only ...

Page 9: ...t strap it is easy to inadvertently let go of the housing especially if you are distracted 5 3 Cleaning Storage The body lid of the housing are made of polycarbonate Polycarbonate was selected for its outstanding strength stiffness hardness and toughness As well as its crystal clear transparency and high gloss surface It has good resistance to weathering although long term exposure to sunlight sho...

Page 10: ...te the nature of the accident so that the severity can be assessed 6 Service To ensure the continued performance of your housing it should be serviced every year or after every 200 dives Please note the terms for servicing the housing posted at our website A full service will include Inspection of all components for wears or damage report if repair necessary Cleaning of all sealing surfaces and re...

Page 11: ...nty Please fill in the information below and return a copy to 10 Bar Underwater Housing at the address below to validate the warranty Housing Type Date of Purchase Serial Number Labeled inside housing Dealer Owner s Name e mail Address Tel Fax Office Showroom Unit C 2 F Wing Hin Factory Building 31 33 Ng Fong St San Po Kong Hong Kong Tel 852 2573 3228 Fax 852 2811 9180 Email service 10bar com Web ...

Reviews: