5.2 General Operation. 

 

The control levers and push buttons consist of internal double O-ring seals on a 

stainless steel shaft. This 

arrangement is very reliable, however as a precaution, when 

operating the controls, avoid excessively rapid 

movements, as this may distort the O-ring.

 

Also please allow for the fact that the camera takes a few 

seconds to power on. If the camera does not appear to respond to a control action, make sure that no other 

controls are pressing on the camera, i.e. locking out further actions.   

Wear the wrist strap; it is easy to inadvertently let go of the housing, especially if you are distracted.   

 

5.3 Cleaning & Storage. 

 

The body & lid of the housing are made of 6061 Aluminum and Acrylic respectively. 6061 Aluminum is 

selected for its outstanding strength stiffness, hardness and toughness, While Acrylic for its crystal clear 

transparency and high gloss surface. Both of them have good resistance to weathering, although long-term 

exposure to sunlight should be avoided. Normal operating temperature range is 3¡C to 36¡C (Storage 

temperature: -10¡C to 50¡C)  

 
It is good practice to rinse off  your housing with  fresh water after every dive.  Avoid to exposure to fine 
sand.  After  a  series  of  10  or  more  dives,  e.g.  after  a  dive  holiday,  it  is  recommended  to  immerse  the 
housing  for  2-3  hours  in  warm  water  to  dissolve  any  salt  deposits  that  may  have  built  up.  No  chemical 
cleaners should be used.   

Important!!!   

For long term storage please remove the main closure o-rings from body. 

 

5.4 Transportation.     

 

Please protect the housing during transportation. It is recommended to remove the handle, and shutter 

extension, and wrap the camera in foam or bubble wrap.     

 

5.5 Accidents   

The impact resistance of the housing is excellent. However after an accident the alignment of the housing 

may have been altered. Therefore in the event of your housing suffering an impact force, e.g. being 

dropped, it is essential that you do not use the housing for diving. Please return the housing immediately 

for service and put a note inside to indicate the nature of the accident, so that the severity can be assessed.   

 

6.    Service

   

To ensure the continued performance of your housing, it should be serviced every year, or after every 200 

dives whichever is earlier. Please note the terms for servicing the housing posted at our website. A full 

service will include:   
 

 

Inspect all components for wears or damage (report if repair 

necessary), 

 

Clean all sealing surfaces,   

 

Replace all O-ring seals,   

 

Hydrostatic pressure test to 10 Bar.   

 

Note: Replacement of damaged components may

 

require additional cost. 

Summary of Contents for LUMIX LX3

Page 1: ...or closure the double o rings and key hole lock design provide ease of use and added security Now you can use small cameras with the feel and function of professional housings 2 Specifications Test Pressure Housings individually tested to 10 Bar 90 m 300 ft Recommended working pressure 60 m Closure Design Double O rings Key hole Lock Body Material 6061 Aluminum Acrylic Overall Size 134 x 152 x 112...

Page 2: ...3 BULKHEAD 14 LOCKING LEVER 15 HOUSING BODY 16 HOUSING LID 17 PORT 3 2 Control Details 1 FLASH ON align the white dot towards the lid press down and turn towards the lighting logo the flash should pop up 2 FLASH OFF turn the Flash On white dot towards the lid turn the button to wards the no lighting logo Make sure that the Flash is turn off before opening the lid 3 FOCUS press to activate confirm ...

Page 3: ...tegrity Each housing is individually inspected and hydrostatically tested in the factory The design of the main piston O ring seal is among the most reliable in the industry and the watertight integrity is excellent This special O ring design provides a perfect seal even if there is any movement between the body and lid due to change of ambient pressure However please note that responsibility for ...

Page 4: ... the outside of the housing is thoroughly toweled dry before opening up After removing the lid and servicing the camera replace the lid straight away rather than leaving it lying around Before replacing the lid check the o rings and make sure that no contamination such as dust hair salt sand etc has fallen onto the O ring or O ring recess as a precaution we recommend to inspect the O ring every ti...

Page 5: ...he Key hole Lock is simple and easy to use and adding security To open the housing make sure that the flash on the camera has been turned off before opening the lid Turn the levers of the lock perpendicular to the wall of the housing until the lock is released on both sides Pull out the lid by holding on the grip near the lock To close the housing place the lid over the housing and align the key h...

Page 6: ...the side wall of the housing Lock the lid by press down the lever and turn until the lever is parallel to the side wall of the housing After replacing and locking the lid make a final visual inspection of the main O ring for contamination Note If the O ring is in good contact a thin black line about 0 5 to 1mm in width should be visible where the O ring is in contact with the lid Follow this line ...

Page 7: ...ad if no sync cord is connected 5 Use Care of Housing 5 1 Pre Dive Function Check Just before entering the water make a habit of reviewing the proper steps to close the housing and connect the bulkhead Make a visual check of the O ring seal It is also useful to switch on the camera and check that controls e g on off zoom shutter functions operate normally Check housing is closed Check O ring is in...

Page 8: ...sand After a series of 10 or more dives e g after a dive holiday it is recommended to immerse the housing for 2 3 hours in warm water to dissolve any salt deposits that may have built up No chemical cleaners should be used Important For long term storage please remove the main closure o rings from body 5 4 Transportation Please protect the housing during transportation It is recommended to remove ...

Page 9: ... the information below and return a copy to 10Bar Underwater Housing at the address below to validate the warranty Copy to be retained by user Housing Type Date of Purchase Serial Number Labeled inside housing Dealer Owner s Name e mail Owner s Address Tel Fax Office Showroom Unit C 2 F Wing Hin Factory Building 31 33 Ng Fong St San Po Kong Hong Kong Tel 852 2573 3228 Fax 852 2811 9180 Email servi...

Reviews: