10 Bar 400D User Manual Download Page 4

4

housings without installing of the camera for their first dive after change of new ports or alternation of any new 

configuration. The test can be carried out by lowering the housing with ballast to the working depth or dive 
down to the safe diving range.

The O-ring seal is the main barrier between the water outside and the air space within the 
camera. It is an effective barrier only if the seal is properly maintained. The O-ring seal should be 

inspected before every dive. The following information is providedyou

¡

re your guidance in using 

and maintaining the O-ring seal.

4.5

 Maintaining the O-ring Seal:

If the main body to lid O-ring is not installed, install the O-ring before diving. This is the only user 

serviceable O-ring. Its care and maintenance is critical to the watertight integrity of the housing. The O-ring 
should be replaced at the service interval (see section on service). If the O-ring is contaminated, or not already 

installed, inspect grease and install the O-ring according to the following guidelines.

4.6

 Inspection, cleaning and re-instillation of the O-ring

Tools:

A soft cotton bud or sponge applicator, make sure these are free of all chemicals or contamination 

such as loose fibers, and the tube of silicone grease supplied with the housing. Note other types of silicone 

grease specifically for use with underwater camera equipment can usually also be used. It is advised to carry 
out the following procedure on a firm clean level surface, (e.g. at a table), to prevent skidding especially useful 

to have when diving from a boat.

When to maintain the O-ring seal:

Remove the O-ring periodically for inspection. It is not necessary to remove, clean and

re-install the O-ring after every dive provided the O-ring did not become contaminated. As a rule of thumb set 

up the camera and housing before a day

¡

s diving. If the housing is required to be opened between dives for 

changing memory card or re-charging batteries, make sure the outside of the housing is thoroughly toweled 
dry before opening up. After removing the lid and servicing the camera, replace the lid straight away, rather 

than leaving it lying around. Before replacing the lid, make sure that no contamination such as dust, hair, salt, 

sand etc. has fallen onto the O-ring or O-ring recess, as a precaution we recommend to inspect the O-ring
every time the lid is opened and to carry out the maintenance if necessary.

Procedure:

Place the lid on a firm non-slip level surface.

The O-ring can be extracted using an O-ring extractor tool (make sure 

the tool as no sharp edges). Alternatively use the flats of the thumbs to 

gently stretch the O-ring on two faces (Fig. 4) thus making a small loop 
protruding a few mm. The loop can then be grasped between finger and 

thumb, to pull the O-ring over the lip.

Clean the O-ring recess (the square groove where the O-ring sits) with 

a cotton bud.

Inspect the O-ring all the way round its surface for damage such as cuts tears or contamination. This should 

be done visually and also by feeling the surface texture between finger and thumb.

IF THE O-RING IS DAMAGED OR SUSPECTED OF BEING DAMAGED, DISCARD IT IMMEDIATELY

A spare O -ring is supplied with your housing, or a replacement O-ring can be obtained from 10 BAR. If the 
O-ring is contaminated or suspected of being contaminated, clean it with a cotton cloth that is free of all 
chemicals or contamination. After cleaning inspect the O-ring again.

Once the O-ring has been inspected and verified fit for use, apply a 

SMALL 

amount of Silicone grease to the 

O-ring. The silicone grease must be evenly distributed round the O-ring

Replace the O-ring into the groove; run a finger round the O-ring, to make sure it is snugly seated in the 

Summary of Contents for 400D

Page 1: ...achined to configure to individual camera model A range of lens ports and controls are fitted to tailor the housing to your camera model 2 Specifications 400D Test Pressure 10 Bar 300 ft Housings are individually tested Closure Design Air Lock Body Material Polycarbonate Overall Size 200 x 300 x 230 mm LxWxH Total Weight Approximately 2 6 Kg Housing only Buoyancy with camera Approximately neutral ...

Page 2: ...12 13 14 15 Cross Key 16 Setting 17 Shutter 18 Main Dial 19 Mode Dail Power on off 20 Flashlight syn bulkhead 21 Zoom control dial 4 Set up Instructions 4 1 Air Lock The body and lid are designed with the Air Lock System no clip closure arrangement Testing has shown that this arrangement allow the water to exert an even pressure on the O ring Increase the reliability of the watertight seal ...

Page 3: ... holes on each corner edges for opening Gently lever off the lid with the supplied opening lever Fig 3 taking care not to twist the lid excessively The lid should be opened keeping it approximately paralleled to the body at all times turn first one corner a little then the other a little and repeat again until the lid is opened Remember to unscrew and pull out the pressure release plug all the way...

Page 4: ...me contaminated As a rule of thumb set up the camera and housing before a day s diving If the housing is required to be opened between dives for changing memory card or re charging batteries make sure the outside of the housing is thoroughly toweled dry before opening up After removing the lid and servicing the camera replace the lid straight away rather than leaving it lying around Before replaci...

Page 5: ... the lid Fig 8 Remember to ensure the pressure release plug is pulled all the way out while closing otherwise the air cannot escape Squeeze the lid closed all the way with the hissing of expelled air Screw home CLOCKWISE the pressure release plug Fig 9 There is no need to excessively tighten this plug The seal is made by internal O rings The O ring on the underside of the plug is just to keep out ...

Page 6: ...g Storage The body lid of the housing are made of polycarbonate Polycarbonate was selected for its outstanding strength stiffness hardness and toughness As well as its crystal clear transparency and high gloss surface It has good resistance to weathering although long term exposure to sunlight should be avoided Normal operating temperature range is 3 C to 36 C Storage temperature 10 C to 50 C It i...

Page 7: ...e The warranty applies only to the housing itself 10 BAR does not accept any liability either implicit or otherwise for any equipment housed inside or used together with the housing In the event of the housing flooding within the period of warranty 10 BAR will repair or replace the housing Please note that disassembly of the housing will invalidate warranty Please fill in the information below and...

Reviews: