background image

OWNER'S MANUAL

Page 20

F3

1000

JFK

SKD

1000

JFK

SKD

1

0

0

0

JF

K

SK

D

471

471

471

471

471

471

471

471

471

471

4

7

1

471

471

4

7

1

4

7

1

4

7

1

4

7

1

4

7

1

471

471

4

7

1

4

7

1

471

ASDF

ASDF

ASDF

ASDF

ASDF

ASDF

N

N

E

 A

C

P

J

A

P

4

S

2

2

0

-5

N

8

 3

D

4

ASDF

ASDF

47

1

47

1

47

1

47

1

U5

47

1

47

1

47

1

47

1

C14

R25

R26

R27

R28

R22

R24

R12

C8

MODEL: 

S1-THEC11NS

082100009

47

1

47

1

47

1

47

1

47

1

47

1

47

1

47

1

47

1

47

1

R20

C12

C13

R16

R18

C11

D7

R20

GAS

ELEC/HP

ELEC/GAS

HP

O

B

Jumper Configuration

Cooling and Heating - Heat Pump with O reversing valve.

Residential Heat Pumps, split systems & package units, with no auxiliary heat.

OUTPUTS

No Demand

With Demand

Cooling Mode
Heating Mode

O

Y

G

O

-  

Y   G

,

    Y active in Heating

4

7

1

R1

R18

C11

D7

GAS

ELEC/HP

ELEC/GAS

HP

O

B

Jumper  #1  (J1)  should  be  set  for 

ELEC/HP

,

Jumper  #2  (J2)  should  be  set  for 

HP

,

 

and   

Jumper  #3  (J3)  should  be  set  for 

O

  for  typical 

heat pump operation.  

Note:  Thermostat does

not  have  Auxiliary  Heat  /  Emergency  Heat 
capability.

HP

J2

O

J3

ELEC/HP

J1

Summary of Contents for S1-THEC11NS

Page 1: ... ostat Digital Therm ostat BatteryorSystemPowered BatteryorSystemPowered Controlupto1 Heat 1 Cool Controlupto1 Heat 1 Cool FahrenheitorCelsius FahrenheitorCelsius Gas ElectricorHeatPump Gas ElectricorHeatPump Model S1 THEC11NS Use with most systems 1 Heat 1 Cool Use with most systems 1 Heat 1 Cool ...

Page 2: ...e Old Thermostat Safety Warnings Front Panel Display Normal Operation Preparation Battery Replacement Warranty Test Operation Troubleshooting Wire Connections Jumper Configuration Fahrenheit or Celsius OWNER S MANUAL S1 THEC11NS ...

Page 3: ... must be replaced at least once every 12 months to ensure proper operation The Low Battery icon will appear on the thermostat display when it is time to replace the batteries If the thermostat is connected to 24v power the batteries should still be installed but are not required When Low Battery is displayed the batteries must be replaced immediately The manufacturer cannot be liable for improper ...

Page 4: ...Location of Controls Page 4 OWNER S MANUAL S1 THEC11NS On or Auto FAN SWITCH DISPLAY MODE SWITCH Cool Off or Heat BATTERY DOOR COOLER WARMER BUTTONS ...

Page 5: ...esired set temperature indicator When this indicator is on the large numbers represent the desired room temperature Pressing the COOLER or WARMER button during normal operation will cause the large numbers to switch from the current room temperature to the desired set temperature Current room or set temperature Indicates battery life is low it is recommended to replace the batteries at this time O...

Page 6: ...eave the fan switched to Auto In Fan Auto the fan will turn on only with a heat or cool demand When Fan On is selected the fan will run continuously Adjust the desired set temperature with the COOLER or WARMER buttons S1 THEC11NS On or Auto FAN SWITCH MODE SWITCH Cool Off or Heat COOLER WARMER BUTTONS ...

Page 7: ...itch Press and hold the COOLER and WARMER buttons at the same time until the temperature is displayed in degrees Celsius Repeat this process to display the temperature in degrees Fahrenheit OWNER S MANUAL S1 THEC11NS MODE SWITCH Cool Off or Heat COOLER WARMER BUTTONS ...

Page 8: ...the screws and instructions Turn off the power to the Heating Air Conditioning system at the main fuse panel Most residential systems have a separate breaker for disconnecting power to the furnace Proper installation of the thermostat will be accomplished by following these step by step instructions If you are unsure about any of these steps call a qualified technician for assistance Preparation O...

Page 9: ...nd lift away Disconnect the wires from the old thermostat Tape the ends of the wires as you disconnect them and mark them with the letter of the terminal for easy reconnection to the new thermostat Keep the old thermostat for reference purposes until your new thermostat is functioning properly Remove Replace Old Thermostat Page 9 OWNER S MANUAL S1 THEC11NS ...

Page 10: ...f the thermostat fig 1 To open the battery slot press down on the battery cover fig 1 and pull out fig 2 Place the bottom hook of the battery cover into the slot and snap closed fig 4 FIG 1 FIG 2 Press down Pull out Battery Slot FIG 4 Snap closed Bottom Hook Remove the old batteries and replace with the new AA alkaline batteries fig 3 FIG 3 New batteries in AA alkaline WARMER COOLER OFF COOL HEAT ...

Page 11: ...ts originating inside the wall from entering the thermostat These drafts left unchecked may cause incorrect room temperature readings Please do not remove this label from the thermostat Insert the wires through the slots provided in the label as shown in Fig 1 Thermal Insulating Sheet RC R M Vr A Power RC Cooling Transformer RH R M Vr A Power RH Heating Transformer The RC and RH terminals have a f...

Page 12: ... is not used the thermostat must be powered by two AA alkaline batteries These batteries must be replaced page 10 each year or when the Low Battery indicator is displayed page 3 4 Wire 1 Stage Cooling 1 Stage Heating Residential Gas or Electric Heat Electric Cool split systems package units For jumper configuration see pages 18 and 19 OWNER S MANUAL Common wire optional Factory installed jumper be...

Page 13: ...VERSING VALVE Y 4 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment OWNER S MANUAL Common wire is optional in all installations If a common wire is not used the thermostat must be powered by two AA alkaline batteries These batteries must be replaced page 10 each year or when the Low Battery indicator is displayed page 3 Common wire optional Factory installed jumper bet...

Page 14: ...RESSOR R REVERSING VALVE Y 4 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment OWNER S MANUAL Common wire is optional in all installations If a common wire is not used the thermostat must be powered by two AA alkaline batteries These batteries must be replaced page 10 each year or when the Low Battery indicator is displayed page 3 Common wire optional Factory installed...

Page 15: ...its with a separately controlled fan For jumper configuration see pages 18 and 19 OWNER S MANUAL Common wire is optional in all installations If a common wire is not used the thermostat must be powered by two AA alkaline batteries These batteries must be replaced page 10 each year or when the Low Battery indicator is displayed page 3 Common wire optional Factory installed jumper between RC and RH ...

Page 16: ...its For jumper configuration see page 18 POWER R W GAS OR ELECTRIC HEAT Common wire is optional in all installations If a common wire is not used the thermostat must be powered by two AA alkaline batteries These batteries must be replaced page 10 each year or when the Low Battery indicator is displayed page 3 Common wire optional Factory installed jumper between RC and RH S1 THEC11NS C RH Y W G RC...

Page 17: ...ting Residential Gas or Electric Heat Electric Cool split systems package units For jumper configuration see pages 18 and 19 Remove the factory installed jumper between RC and RH COMPRESSOR Y RC POWER COOL FAN G W GAS OR ELECTRIC HEAT RH POWER HEAT Cooling System Heating System If a common wire is used it must be connected to the furnace common terminal If a common wire is not used the thermostat ...

Page 18: ...LEC GAS for for typical gas furnace heating with electric cooling Jumper 3 J3 is not used 1000 JFK SKD 1000 JFK SKD 1000 JFK SKD 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 ASDF ASDF ASDF ASDF ASDF ASDF NNE ACPJA P4S220 5 N8 3D4 ASDF ASDF 471 471 471 471 U5 471 471 471 471 C14 R25 R26 R27 R28 R22 R24 R12 C8 471 471 471 471 471 471 471 471 471 471 R20...

Page 19: ...ELEC GAS for for typical electric heating with electric cooling Jumper 3 J3 is not used 1000 JFK SKD 1000 JFK SKD 1000 JFK SKD 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 ASDF ASDF ASDF ASDF ASDF ASDF NNE ACPJA P4S220 5 N8 3D4 ASDF ASDF 471 471 471 471 U5 471 471 471 471 C14 R25 R26 R27 R28 R22 R24 R12 C8 MODEL S1 THEC11NS 082100009 471 471 471 471 4...

Page 20: ...12 C13 R16 R18 C11 D7 R20 GAS ELEC HP ELEC GAS HP O B Jumper Configuration Cooling and Heating Heat Pump with O reversing valve Residential Heat Pumps split systems package units with no auxiliary heat OUTPUTS No Demand With Demand Cooling Mode Heating Mode O Y G O Y G Y active in Heating 471 R1 R18 C11 D7 GAS ELEC HP ELEC GAS HP O B Jumper 1 J1 should be set for ELEC HP Jumper 2 J2 should be set ...

Page 21: ...20 GAS ELEC HP ELEC GAS HP O B Jumper Configuration Cooling and Heating Heat Pump with B reversing valve Residential Heat Pumps split systems package units with no auxiliary heat OUTPUTS No Demand With Demand Cooling Mode Heating Mode Y G B Y G B Y active in Heating 471 R1 R18 C11 D7 GAS ELEC HP ELEC GAS HP O B Jumper 1 J1 should be set for ELEC HP Jumper 2 J2 should be set for HP and Jumper 3 J3 ...

Page 22: ... the thermostat slide the Mode Switch to COOL Press the COOLER or WARMER buttons until the set temperature is 10 degrees below room temperature The HVAC unit should energize in the cooling mode Page 6 Note You may need to wait up to five minutes for cooling to energize due to the compressor lockout feature Turn on the power to the Heating Air Conditioning system On the thermostat slide the Mode Sw...

Page 23: ...rn on CAUSE The cooling setpoint is set too high the Mode Switch is not set for Cool or the batteries are too weak REMEDY Consult the Normal Operation section in this manual to Lower the cooling setpoint Page 6 Correct the Mode Switch position Page 6 Replace the batteries Page 10 OWNER S MANUAL SYMPTOM The fan does not turn on even though the compressor has energized CAUSE The Fan Switch is not co...

Page 24: ...ch is not set for Heat or the batteries are too weak REMEDY Consult the Normal Operation section in this manual to Raise the heating setpoint Page 6 Correct the Mode Switch position Page 6 Replace the batteries Page 10 S1 THEC11NS 4Z95 P N 88 548 Rev 4 C c F FOR HOME OR OFFICE USE Tested to Comply with FCC Standards Battery Stat P N S1 THEC11NS ...

Page 25: ...ERSON WHATSOEVER ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS ALL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR 1 Normal maintenance as outlined in the installation and servicing instructions or owner s manual including filter cl...

Reviews: