1. Drill two holes at the distance of 

54mm apart.

2. Insert screw anchors and screws 

(not provided) into the holes.

3. Hang the PMG2005-T20C on the 

screws.

The PMG2005-T20C doesn't turn on.

- Make sure the power cable is connected, and you've pressed the power button.
- Make sure the power adaptor is connected to an appropriate power source. Make sure the power 

source is turned on.

I cannot see or access the Login screen in the Web Configurator.

- Make sure you are using the correct IP address.

• The default IP address is 192.168.1.1.
• If you changed the IP address and have forgotten it, you have to reset the PMG2005-T20C to its 
  factory defaults.

- Make sure your Internet browser does not block pop-up windows and has JavaScript enabled.
- Make sure you have entered the 

User Name

 and 

Login Password 

correctly.

Enter the default 

User Name

 (admin) and admin 

Login Password 

(on the device label), and then click 

Login

. If you changed the default password, please enter the new password. If you cannot remember 

the new password, use a pin to push the RESET button for more than 5 seconds to return the device to 

the factory defaults, including admin password on the back label.

I cannot access the Internet.

- Check the hardware connections and the LED behavior. If the 

PON

 LED is off, restart the 

   PMG2005-T20C. Check if the fiber cable has come loose or is damaged. Contact the vendor to   
   replace any damaged cables.
- If you were given ISP account information, log into the web configurator and check that the settings 
   are correct in the

 Interface > Internet

 and 

Maintenance > System Restart

 menus. 

- Disconnect all the cables from the PMG2005-T20C and reconnect them.

54 mm

Troubleshooting

Wall Mounting

 (Optional)

Configuration 

(Optional)

PMG2005-T20C

User Name

Password

XXXXXXXXXX

admin

Login

User Name : 

admin

Password : 

Refer to the device label

(default)

http://192.168.1.1

5

If you want to configure router 

settings, change the admin 

password, see traffic statistics, 

upload new firmware or reset to 

the factory defaults, open a web 

browser and go to http://192.168.1.1. 

Enter the default 

User Name 

(admin) 

and admin 

Login 

Password

 (on the device label), 

and then click 

Login

.

Note: If problems persist, please contact your vendor or customer support.

x2

Unit: mm

18.0~22.0

3.5~4.2

x2

18.0~22.0

2.8~3.2

2.01~2.50

4.5~5.5

Unit: mm

Tapping Screw M4x30 mm