NetAtlas Enterprise Ethernet Switch Manager User’s Guide
153
Chapter 16 Ethernet Port Configuration
\
The following table describes the labels in this screen.
Table 79
Ethernet Port Configuration: Bandwidth Ctrl.
LABEL
DESCRIPTION
Active
Select this check box to enable bandwidth control on the selected port(s).
You may temporarily deactivate a rule without deleting it by clearing this check box.
Ingress Rate
Type the maximum bandwidth allowed in kilobits per second (Kbps) for traffic coming
into this port.
Commited
Rate
Specify the guaranteed bandwidth allowed in kilobits per second (Kbps) for the incoming
traffic flow on a port. The commit rate should be less than the peak rate. The sum of
commit rates cannot be greater than or equal to the uplink bandwidth.
Peak Rate
Specify the maximum bandwidth allowed in kilobits per second (Kbps) for the incoming
traffic flow on a port.
Egress Rate
Type the maximum bandwidth allowed in kilobits per second (Kbps) for traffic going out
of this port.
Scheme
Select
Drop
(default) from the drop-down list box to discard all incoming packets that
are over the maximum allowable bandwidth on a port.
A concentration of traffic on a port decreases port bandwidth and overflows buffer
memory causing packet discards and frame losses.
Flow Control
is used to regulate
transmission of signals to match the bandwidth of the receiving port.
The switch uses IEEE 802.3x flow control in full duplex mode and backpressure flow
control in half duplex mode.
IEEE 802.3x flow control is used in full duplex mode to send a pause signal to the
sending port, causing it to temporarily stop sending signals when the receiving port
memory buffers fill. Back Pressure flow control is typically used in half duplex mode to
send a "collision" signal to the sending port (mimicking a state of packet collision)
causing the sending port to temporarily stop sending signals and resend later. Select
this option to enable flow control.
Apply
Click
Apply
to save the changes.
Содержание NETATLAS ENTERPRISE -
Страница 1: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide Version 1 02 1 2006 ...
Страница 21: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 21 List of Tables ...
Страница 27: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 27 Chapter 1 Introduction ...
Страница 34: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide Chapter 2 Switch Manager 34 Figure 9 EMS Main Screen ...
Страница 35: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 35 Chapter 2 Switch Manager ...
Страница 45: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 45 Chapter 3 EMS Main Window ...
Страница 67: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 67 Chapter 5 View ...
Страница 91: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 91 Chapter 9 Fault ...
Страница 99: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 99 Chapter 10 Maintenance ...
Страница 102: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide Chapter 11 Tools 102 Figure 65 Tool Ping ...
Страница 103: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 103 Chapter 11 Tools ...
Страница 109: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 109 Chapter 12 Device Menu Overview ...
Страница 119: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 119 Chapter 13 System Configuration ...
Страница 133: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 133 Chapter 14 Switch Configuration ...
Страница 191: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 191 Appendix A SNMPc Network Manager ...
Страница 193: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 193 Appendix B ...