TN01U Thermometer Operation Instructions 

Thank you for purchasing our non-contact infrared thermometer. Please remember to keep away from children and 

don’t use it for safety related applications. 

                           

 

Specifications: 

;

 

Temperature measurement range: -55 to +220°C (-67~428°F) 

;

 

Operating temperature range: 0 to +50°C (32 to +122°F) 

;

 

Resolution: 0.2°C /0.5°F (for thermometer); 0.01sec (for Stop Watch) 

;

 

Accuracy (Tamb=23±3

°

C): -55~0°C: +/-(2+0.05/deg)°C; above 0°C: +/-2°C(4°F) or +/-2% of the reading, 

whichever is greater 

;

 

Measurement Distance is18mm, Spot Size is 2.5 mm   

;

 

Emissivity Range: 0.95 default –adjustable 0.05 to 1 

;

 

Auto real time clock and Room temperature while power off 

;

 

°C / °F Switch, MIN/MAX/LOCK, Stop Watch function 

;

 

Battery Life: 15 hours continuous use (auto power off after 15seconds), The battery life of the shelf =8month. 

;

 

Power Supply:: AAA*2 batteries 

 

Real time clock setting

 

1

 

Power on: Press the “Meas. key”. 

2

 

Press the “Mode key” seven times and the “

Set

” icon starts 

to flash, which indicates the setting screen. 

3

 

Press the “Meas. key” to make the “24” icon flashing, which 
indicates the 12/24-hour setting screen.   
Press the “Meas. key” again to set 12/24-hour Format from 
24-hour to 12-hour.   

4

 

Press the “Mode key” to move the flashing in the sequence shown below to select other settings. 
Hour 

Æ

 Minutes   

5

 

While the hour, minutes setting is flashing, use “Meas. key” to change it. Press “Mode key” when complete. 

 

Use of the thermometer 

1

 

Always make sure the sensor lens is clean without any damage. 

2

 

Power on: Press the “Meas. key”. 

3

 

Temperature taking: Remove the head cover before taking 

temperature. When you press the “Meas. key”, will get the 
temperature immediately. If you hold down the “Meas. key”, the 
reading of measurement will be continuous updated.   
*Note: The measurement distance is18mm. Please make sure the 

          target is located at the focus point where two laser dots converged into one. 

Note: Applications include the Water, Milk, Cloth, Skin, or visit Http://www.ZyTemp.com for further information. 
Power off: Device will automatically power off if left idle for more than 15sec to extend battery life 

**If you have set the“ clock” mode, after “power-off”,

 

room temperature & clock will be showed on the 

screen immediately.   

 CAUTION 

1.

 

WHEN DEVICE IS IN USE, DO NOT LOOK DIRECTLY INTO THE LASER BEAM–PERMANENT EYE DAMAGE 
MAY RESULT. 

2.

 

USE EXTREME CAUTION WHEN OPERATING THE LASER. 

3.

 

NEVER POINT THE DEVICE TOWARDS ANYONE’S EYES.   

4.

 

KEEP OUT OF REACH OF ALL CHILDREN. 

 

Use of the Stop Watch

 

1

 

Power on: Press the “Meas. key”. 

2

 

Press the “Mode key” four times and the “count” 

icon starts to flash. 

3

 

For start or stop counting, press the “Meas. key”.   
For reset counting, press the “Mode key”. 

4

 

Press “Mode key” to enter the thermometer 

function 

 

Other Functions

 

MIN

 / 

MAX

 

Æ

 Power on and press the “Mode key” once for the Minimum (MIN) or 

twice for Maximum (MAX) modes. When the MIN or MAX icon flashes, 
press the “Meas. key” to confirm. Hold down the “Meas. key”, the minimum 
or maximum reading of measurement will be continuous updated. 

 

LOCK

 

Æ

 Power on and press the “Mode key” three times. When the LOCK icon 

flashes, press the “Meas. key” to confirm. This mode is particularly useful 
for continuous monitoring of temperatures for up to 60 minutes or until the 
“Meas. key” is pressed. 

 

°C / °F 

Æ

 Power on and press the “Mode key” five times. When the °C icon 

flashes, press the “Meas. key” to change the scale to °F. The setting will be 
reserved even if power off.   

 

Emissivity 

Æ

 Power on and press the “Mode key” six times. When the default 

emissivity “95E” appears, press the “Meas. key” to modify the emissivity 
setting. Press “Mode key” when complete. The setting will be reserved even 
if power off.   

 

Battery replacement 

The thermometer incorporates visual low battery indication as follows: 

 

 

 

Battery OK’: measurements 

 are possible

 

‘Battery Low’: battery needs to be   

replaced, measurements are still possible 

‘Battery Exhausted’: measurements are 

not possible 

Ù

 

 

(12/24-hour setting screen) 

   

 

Ù

 

 

  (Power off)        (Power on) 

           

 

30min                               

30min  

Min:Sec = 01:28 & 0.75sec    Hour:Min:Sec = 01:28:47.5sec 

(resolution=0.01sec, range to 24hr) 

 