INSTALLATION
SPECIFICATIONS
ELECTRICAL
30" – 45"
35-3/8"
19-1/2"
All Electrical work must by performed by qualified electrician or person with similar technical
know how and background.
For personal safety, remove house fuse or open circuit breaker before beginning installation.
Do not use extension cord or adapter plug with this appliance.
Follow National electrical codes or prevailing local codes and ordinances.
Electrical Supply:
This appliance requires a 120V 60Hz electrical supply., and connected to an individual, properly
grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring
must be 2 wire w/ ground. Please also refer Electrical Diagram labeled on product.
Cable Lock:
A cable locking connector (not
supplied) might also required by
local codes. Check with local
requirements and codes, purchase
and install appropriate connector if
necessary.
Cable Lock
WARNING
Model: ZSA-M90S
Page 3
INSTALLATION
DUCTING
WARNING FIRE HAZARD
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or
garages. All exhaust must be ducted to the outside.
Use Metal ductwork only.
Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or DuctTape.
Some Ducting Options:
side wall cap
w/ gravity damper
side wall cap
w/ gravity damper
Soffit or crawl space
Roof Pitch w/
Flashing & Cap
Model: ZSA-M90S
Page 2