INSTALLATION

SPECIFICATIONS

ELECTRICAL

30" – 45"

35-3/8"

19-1/2"

All Electrical work must by performed by qualified electrician or person with similar technical
know how and background.

For personal safety, remove house fuse or open circuit breaker before beginning installation.
Do not use extension cord or adapter plug with this appliance.

Follow National electrical codes or prevailing local codes and ordinances.

Electrical Supply:

This appliance requires a 120V 60Hz electrical supply., and connected to an individual, properly
grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring
must be 2 wire w/ ground. Please also refer Electrical Diagram labeled on product.

Cable Lock:

A cable locking connector (not
supplied) might also required by
local codes. Check with local
requirements and codes, purchase
and install appropriate connector if
necessary.

Cable Lock

WARNING 

Model: ZSA-M90S    

Page 3

INSTALLATION

DUCTING

WARNING FIRE HAZARD

NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or
garages. All exhaust must be ducted to the outside.

Use Metal ductwork only.

Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or DuctTape.

Some Ducting Options:

side wall cap
w/ gravity damper

side wall cap
w/ gravity damper

Soffit or crawl space

Roof Pitch w/ 
Flashing & Cap

Model: ZSA-M90S    

Page 2