RFSoC Data Converter Evaluation Tool User Guide
31
UG1287 (v2018.2) October 1, 2018
Chapter 4:
Clocking
lists the clocks used for the RF-ADC control path and datapath.
The RF-DAC has 300 MHz and DAC_CLK_OUT (409.625 MHz) clock domains. The
DAC_CLK_OUT is an output of RF data converter block (usp_rf_data_converter_0) and is
currently being configured to 409.625 MHz.
and
clock domains.
Table 4-1:
Clock Domains in RF-ADC Control and Datapath
Logic Block
ADC Stream
Clock Domain
(512 MHz)
Clock Domain
(300 MHz)
ADC Clock Domain
(256 MHz)
ADC (usp_rf_data_converter)
X
Channel select multiplexer
X
FIFO (axis_data_fifo_0) (ADC 0-ADC7)
Asynchronous FIFO
X (WRITE Clock)
X (READ Clock)
DMA (axi_dma)
X
AXI interconnect (AXI smart connect)
X
PL DDR controller interface
X
ADC_0 I & Q Merge
X
ADC_1 I & Q Merge
X
ADC_2 I & Q Merge
X
ADC_3 I & Q Merge
X
ADC_4 I & Q Merge
X
ADC_5 I & Q Merge
X
ADC_6 I & Q Merge
X
ADC_7 I & Q Merge
X