           Control Parameters

Operation        Occupied  
   Mode       DMX Channels         Control Channels        DMX Value            Output Value

 

4COL 

 4  Red 

 0-255 

 0-100%

    Green 

 0-255 

 0-100%

    Blue 

 0-255 

 0-100%

    White 

 0-255 

 0-100%

 

HIS 

 3  Intensity 

 0-255 

 0-100%

    Hue 

 0-255 

 0-360º

    Saturation 0-255 

 0-100%

 

FIL 

 2  Brightness 0-255 

 0-100%

    Effect 

(16 

Colors) 

0-15 

 Clear

      16-31 

 Pale 

Gold

      32-47 

 Straw

      48-63 

 Loving 

Amber

      64-79 

 Chrome 

Orange

      80-95 

 Bright 

Pink

      96-111 

 Flesh 

Pink

      112-127 

 Magenta

      128-143 

 Bright 

Red

      144-159 

 Rose 

Purple

      160-175 

 Mauve

      176-191 

 Moss 

Green

      192-207 

 Dark 

green

      208-223 

 Full 

CT 

BLue

      224-239 

 Peacock 

Blue

      240-255 

 Dark 

Blue

 

CCT 

 2  Brightness 0-255 

 0-100%

 

    Color 

Temp. 

0-63 

 3200K

      64-126 

 4500K

      127-189 

 5600K

      190-255 

 7500K

Maintenance:

To eliminate unnecessary wear and improve lifespan, during periods 
of non-use, completely disconnect the product from power via 
breaker or by unplugging it.

Expected  LED  Lifespan:

LEDs  gradually   decline  in  brightness over  time, mostly because of  
heat.  Packaged  in clusters, LEDs exhibit higher operating
temperatures than in ideal, single-LED conditions. For this reason, 
using  clustered LEDs at their fullest intensity significantly reduces the 
LEDs’ lifespan. Under normal conditions, this lifespan can be 20,000 
hours at 25 °C (77 °F). If extending this lifespan is vital, lowering the  
operating temperature by improving the ventilation around the 
product and reducing the ambient temperature is recommended.

Page 12

Содержание Pro-Palette

Страница 1: ...Pro Palette Color LED Cyclorama User Instructions Pro Palette Manual v1 0...

Страница 2: ...or tune your talent or set Placed on the floor or mounted on in the grid the Pro Palette brings new levels of flexibility creativity and control to your stage or theater Zylight is thoroughly committe...

Страница 3: ...lette has been thoroughly tested and has been shipped in optimal operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be d...

Страница 4: ...ht com Caution There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufacturer s warranty In the unlikely event your unit may require serv...

Страница 5: ...com product registration and register your product and validate your purchase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R...

Страница 6: ...iods of non use disconnect the fixture s main power Always mount this fixture in safe and stable matter Always use a safety cable as part of a secure installation Use only a butterfly style hook which...

Страница 7: ...extremely user friendly 4COL HSI FIL and CCT 1 4COL Red Green Blue White Using four channels for four colours independently this is a traditional way to control color changing LED fixtures Color is m...

Страница 8: ...r filter codes for reference only DMX Color Code 1 0 15 Clear 130 2 16 31 Pale Gold 152 3 32 47 Straw 103 4 48 63 Loving Amber 176 5 64 79 Chrome Orange 179 6 80 95 Bright Pink 128 7 96 111 Flesh Pink...

Страница 9: ...the white connector To avoid overloading the maximum looping for the Pro Palette is five units at 220V or three units at 110V The Pro Palette comes with a power cable terminated with a PowerCon connec...

Страница 10: ...Instruction of data transmission reliability 1 Use a shielded twisted pair designed for RS 485 standard microphone cable is unsuitable for long distances and the transmission distance of the 24AWG cab...

Страница 11: ...ventilation configuration and maintenance The fixture comes with a hanging mounting yoke to attach mounting clamps The bracket has a 12 mm hole Make sure the clamps are capable of supporting the weigh...

Страница 12: ...ction knob to change the dimming address dimming address range 1 512 and press the Function Knob once to save Under the SET menu press the Function Knob to display any one of 4COL HSI FIL CCT on the i...

Страница 13: ...255 0 100 Color Temp 0 63 3200K 64 126 4500K 127 189 5600K 190 255 7500K Maintenance To eliminate unnecessary wear and improve lifespan during periods of non use completely disconnect the product from...

Страница 14: ...expiration of the warranty period This warranty does not cover a damage or failure caused by or attributable to acts of God abuse accident drops misuse improper or abnormal usage failure to follow ins...

Страница 15: ...o warranties whether expressed or implied including warranties of merchantability or fitness shall apply to this product after said period has expired The Consumer s and or Dealer s sole remedy shall...

Страница 16: ...10718 McCune Avenue Zylight LLC World Headquarters Los Angeles CA 90034 978 244 0011 info zylight com...

Отзывы: