background image

Z-Wave™ Configuration Parameters

You may use the below configuration parameters to change settings of the corresponding functionality.

1: Locally Button function
      Paramter No: 1(0x01)     Size:1 Byte     
                               Value: 00(default)    Up Button ON,Down Button OFF 
                               Value: 01                Up Button OFF,Down Button ON
                               Value: 02                Up Button ON/OFF,Down Button ON/OFF
2:Status LED Configuration
      Paramter No: 2(0x02)     Size:1 Byte         
                               Value: 00(default)    Output and the LED are in the different state.
                               Value: 01              Output and the LED are in the same state.
                               Value: 02               LED  Always OFF
                               Value: 03               LED  Always ON
3: Auto Turn-Off Timer  
      Paramter No: 3(0x03),   Size=4,
                               Values:0 (minutes) default;
                               Values: 1 – 65535 (minutes);
5: Auto Turn-Off Timer  
      Paramter No: 5(0x05),   Size=4,
                               Values:0 (minutes) default;
                               Values: 1 – 65535 (minutes);
8:Restores state after power failure
      Paramter No: 8(0x08)     Size:1 Byte         
                               Value: 00                  Output OFF.
                               Value: 01                  Output ON.
                               Value: 02 (default)   The state before a power outage.
9: Ramp rate(Local  Z-Wave™)
      Paramter No: 9(0x09),   Size=1,Default =1
                               Value=1    from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
                               Value=2  from 0x63 to 0x00 or from 0x00 to 0x63 need 2s
                                  ......
                               Value=99  from 0x63 to 0x00 or from 0x00 to 0x63 need 99s
10: Multilevel minimum value can be set(Local Button)
      Paramter No: 10(0x0A),  Size=1,Default =1                                        
                               Value=0     disable 
                               Value=1     
                               Value=2     
                                  ......
                               Value=99
11: Multilevel maximum value can be set(Local Button)
      Paramter No: 11(0x0B),  Size=1,Default =99
                               Value=0     disable 
                               Value=1     
                               Value=2     
                                  ......
                               Value=99
12:Double Tap Behavior---when switch is off and quickly press UPPER paddle 2 times, switch turns on to x brightness
      Paramter No: 12(0x0C),  Size=1,Default =0
                               Value=0     enable double tap to full brightness (99)
                               Value=1     custom value set in parameter 18
                               Value=2     enable double tap to maximum brightness (turn on to the value relate with parameter 11)
                               Value=3     disable double tap to full brightness
15: Enable or Disable local / Z-Wave™ control 
      Paramter No: 15(0x0F)    Size:1 ,Default =1
                               Value: 00    disable
                                            (when paddle pressed switch will not turn light on or off BUT it will still control the light via z-wave™ and 
                                              it will change LED indicator status and on/off/multilevel status when paddle is pressed)
                               Value: 01    enable (normal operation like now)
                               Value: 02    disable local and Z-Wave™ control
                                            (LED and on/off status will still change if paddle pressed) >> 
                                              make sure that status is still reported and LED indicator changes when Z-Wave™ control is disabled
16: dimmer speed (only for local press & hold)
      Paramter No: 16(0x10),  Size=1,Default =5
                               Value=1    from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
                               Value=2  from 0x63 to 0x00 or from 0x00 to 0x63 need 2s
                                  ......
                               Value=99  from 0x63 to 0x00 or from 0x00 to 0x63 need 99s
18:Custom brightness level--
   in this parameter define default brightness level the switch will turn on to from main switch or regular switch in 3-way when pressed upper paddle once.
      Paramter No: 18(0x12),  Size=1,Default =0
                               Value=0           last brightness level
                               Value=(1--99)     custom brightness level
19: 3-way switch type
      Paramter No: 19(0x13)    Size:1 ,Default =0
                               Value: 00    toggle switch
                               Value: 01    toggle switch
               press 1x change device status;quickly press 2x the result depend on  Par11/Par12; quickly Press 3x it trigger dimmer in loop
                               Value: 02    momentary switch
               press 1x change device status;quickly press 2x the result depend on  Par11/Par12;hold  trigger dimmer in loop
                               Value: 03    momentary switch
               press 1x change device status;quickly press 2x the result depend on  Par11/Par12;hold  trigger dimmer in loop(dimmer up/dimmer down –
               BUT after double click to full brightness, hold will dim DOWN always instead of trying to increase brightness)
20: Association reports
      Paramter No: 20(0x14)    Size:1 ,Default =2
                               Value: 00    Z-Wave™ control:Multilevel report (without each level,just final level)
                                            Manual control (short press): Basic report(without each level,just final level)
                                            Manual control(long press & relay enable): Basic report(without each level,just final level)
                                            Manual control(long press & relay disable): Multilevel report (each level will be reported)
                               Value: 01    Z-Wave™ control:Multilevel report (without each level,just final level)
                                            Manual control (short press): Basic report(without each level,just final level)
                                            Manual control(long press & relay enable OR disable): Basic report 
                               Value: 02    Z-Wave™ control:Multilevel report (without each level, just final level)
                                            Manual control (short press): Multilevel report (without each level, just final level)
                                            Manual control (long press & relay enable): Multilevel report (without each level, just final level)
                                            Manual control (long press & relay disable): Multilevel report (each level will be reported)
21: Disabled Relay Behavior
      Paramter No: 21(0x15)    Size:1 ,Default =0
                               Value: 00    report on/off and multilevel  status when paddle is pressed and change LED indicator  status and 
                                                Parameter 15 is set to value 0 or 2 (output control disabled) according to setting in Parameter 20