Page 20
3.5.4 Alarm output
Please check current channel status: “
#
” means it is not in alarming status, “
$
” means it is in
alarming status.
You can use desktop shortcut menu or click [main menu]> [alarm function]> [alarm output] to
enter the alarm output interface.
Picture 3.9 alarm output
【
Configuration
】
Alarm is on according to the configuration.
【
Manual
】
Click the all button and the according channel is alarming no matter the channel in any
state.
【
Stop
】
Click the stop button and the according channel stops alarming no matter the channel in any
state.
3.5.5 PTZ control
Operation interface is as followed. The functions include: PTZ direction control, step, zoom, focus,
iris, setup operation, patrol between spots, trail patrol, boundary scan, assistant switch, light switch,
level rotation and so on.
Note
1. Decoder A(B)line connects with DVR A(B)line. The connection is right.
2. Click [main menu] >[system configuration] >[PTZ setup] to set the PTZ parameters.
3. The PTZ functions are decided by the PTZ protocols.