1.  Open the upper cover with the key
2.  Unplug the connector from the battery case
3.  Open the liquid container, and pour liquid/soap. Please clean 

any excess liquid/soap

4.  Attach the connector back into the battery case, put the upper 

cover back and lock it with the key

First mount the dispenser onto the wall. Power on the dispenser and the indicator will flash 5 times. If there is no object in front of the 

sensor for 30 seconds, the setting function will be locked and will go into the factory setting. 

Adjustment of sensor distance:

Adjustment of liquid/soap volume:

1. 

Press and hold the setting button for 15 seconds, the indicator will flash 5 times. The dispenser has entered the setting state. 

2. 

Press and hold the setting button again for 5 seconds and the indicator will start flashing

3. 

When the indicator starts flashing, put your hand under the dispenser at the distance that you want to set

4. 

Leave your hand at the same postion until the indicator is off

1. 

Press and hold the setting button for 15 seconds, the indicator will flash 5 times. The dispenser has entered the setting state. 

2. 

Press the setting button 2 times (The indicator will flash once after pressing the button the first time, press the setting button once 

the light is off)

3. 

The indicator will flash 5 times. Place your hand underneath the dispenser. 

4. 

There are 7 different levels for the dispenser and the moment it dispenses the perfect amount of soap, move your hand away from 

dispenser. 

Note: Please make sure that all the adjustments of liquid volume and and sensor distance are complete within 30 seconds. Otherwise 

the setting function will be locked and the setting button will need to be pressed again for 15 seconds and the procedure will have to be 

repeated. 

Liquid/Soap Fill and Startup Instruction

Bottom of Dispenser

Outlet

Sensor Window

Setting Button

5. 

Place hand under sensor window. The LED indicator will flash 

and liquid will be dispensed. 

6.  Press the setting button and keep hand underneath sensor for 

more than 2 seconds until fluid is dispensed

Adjust Distance and Liquid Soap Volume

Note:  If using the gel type (Z6900-SD-WM), and the liquid is highly viscous, it is recommended to mix a small amount of fluid with 

water to thin the solution to properly prime the pump. Once priming has occurred (see step 6), fill reservoir with liquid of choice

Note:  Remove the mask on lens before operating

Содержание Z6900-SD-WM

Страница 1: ...ver including incidental or consequential damages The sole and exclusive remedy shall be limited to the replacement of the defective goods Before installation and use the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantabi lity is ex...

Страница 2: ...This Page Intentionally Left Blank ...

Страница 3: ...ure DC 9V 6 AA Batteries Included Standby 0 4W Operation 1 2W 2 6 adjustable 650 ml 22 l oz 0 8 6 5 ml liquid 10 25 ml foam adjustable 100 3800 cPs 34 110 F Cover for Can Key Upper Cover Battery Case Mounting Plate Sealing Ring Can Peristaltic Pump Sensor Controller Bottom Outlet Hand Drill 1 4 or 6mm Drill Bits Phillips Head Screwdriver Parts List Required Tools Specifications ...

Страница 4: ... manual for the life of the dispenser 6 Do not put objects such as stainless steel objects or photoelectric sensors underneath the sensor window of the dispenser 7 Please install the dispenser in an area with little sunlightv WARNING 1 The dispenser must be set in dormant state before its operation The dispenser must be run once per 72 hours to ensure no loss of performance from the silicone tube ...

Страница 5: ...es according to the mounting plate and attach the mounting plate to the wall using the plastic anchors and screws 3 Attach the dispenser by the mounting plate s hook 4 Press the dispenser down to attach it to the hook tightly 5 Open the upper cover using the key 6 Fix the dispenser to the mounting plate with a screw Soap Dispenser Installation Instruction ...

Страница 6: ...the setting state 2 Press the setting button 2 times The indicator will flash once after pressing the button the first time press the setting button once the light is off 3 The indicator will flash 5 times Place your hand underneath the dispenser 4 There are 7 different levels for the dispenser and the moment it dispenses the perfect amount of soap move your hand away from dispenser Note Please ma...

Страница 7: ...utral liquid to clean the surfaces Then use a damp cloth to wipe off excess liquid and dry the surfaces with a dry soft cloth Avoid submerging the dispenser or spraying water on the dispenser Do not use soap detergents or liquids with high acidity or high alkalinity Avoid using nylon brushes or rough cleaning devices 3 Do not damage the sensor window as the sensitivity wll be reduced Phenomenon Pr...

Страница 8: ...TRIES LLC 511 W Freshwater Way Milwaukee WI U S A 53204 Ph 1 855 ONE ZURN Fax 919 775 3541 In Canada ZURN INDUSTRIES LIMITED 7900 Goreway Drive Unit 10 Brampton Ontario L6T 5W6 Ph 905 405 8272 Fax 905 405 1292 Rev A Date 10 22 20 C N No 143132 Prod Dwg No FV761 ...

Отзывы: