Page 7
Installing Mounting Bracket
•
Secure the mounting bracket to the plywood cut-out with supplied washers, bolts and toggle an-
chors on the plywood.
Retrofitting Hanger Bracket
Installation
Recommended for retrofit:
• Measure the rough in dimensions on the wall. Top edge of the
cutout marked must be 2” below the basin top back edge.
• Cut the drywall to suitable size (60”x20”) and attach a min-
imum of 1/2” thick plywood to the wall stud and flush to the
drywall.
• Drill eight ¾” holes in the plywood at the locations shown in the
graphic to the left. Then, install the supplied toggle anchors to
wall and secure the hanger bracket(s) directly to the plywood
with the supplied bolts.
• Install hanger bracket to wall per structural rough-in.
(Note: An offset might be necessary on applications using tile
to get the basin and mounting brackets flush with the wall and
mating bracket
• The plywood should not be visible after basin and shroud
installation.
• The bracket needs to be checked for level after installation.
21
19
20
Plywood
Wall Stud
Bolt supplied by
installer to attach
the plywood to
wall studs
Hanger
Bracket
Mounting
Bracket
21
19
20
Plywood
Wall Stud
Bolt supplied by
installer to attach
the plywood to
wall studs
Warning: Must be handled by at least 2 people
Warning: Ensure the basin back edge is completely supported in the wall bracket.
Avertissement : s’y prendre à deux minimum.
Avertissement : s’assurer que le bord arrière du bac est complètement soutenu par le support mural.
1 [25]
312 [89]
4 [99]
312 [89]