background image

PAGE 1 OF 4

ZURN INDUSTRIES, LLC 

5900 Elwin Buchanan Drive, Sanford, NC U.S.A. 27330, Ph. 1-800-997-3876, Fax 919-775-3541

In Canada: 

ZURN INDUSTRIES LIMITED 

7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, Ph. 905-405-8272, Fax 905-405-1292

Rev. A 

Date: 6/25/2018 

C.N. No. SAN008311  

Prod. | Dwg. No. 

CF1203

 Installation

 

 

Maintenance Instructions

 

 

Replacement Kits

Z7440-XL AND Z7440-XL-CST Series Single Handle Lavatory 

Faucet With Adjustable Temperature Limit Stop

CONGRATULATIONS

You have purchased a ZURN Quality Manufactured lavatory 

faucet that contains a "life of the system" ceramic cartridge. The 

Sierra faucet will provide you with years of trouble free service. If 

you should have any questions, please contact your local ZURN/

TEMP-GARD representative or the factory at the address on the 

back of this sheet.

1. Shut off hot and cold water supplies.

2. Place faucet base plate on faucet and position on lavatory  

sink. 

In some installations, a sealant may be required to 

make a water tight seal between the faucet base plate 

and the mounting surface. The installer should verify the 

compatibility of the selected sealant with the mounting 

surface manufacturer. Both plumber’s putty and silicone  

sealants are compatible with Zurn faucets and fixtures.   

Consult the mounting surface manufacture for their  

 

recommendation of sealant.

 

From underneath the sink,    

position bracket on mounting studs and attach the hex nuts.   

Tighten hex nuts.

3. If faucet includes pop-up or grid drain, refer to next   

 

page for pop-up assembly installation.

4. Connect left inlet tube to hot water supply and right inlet  

 

tube to cold water supply. 

CAUTION: Care should be taken  

not to kink tubes when connecting to water supplies.

INSTALLATION INSTRUCTIONS

Item

Part Number

Description

Qty.

1

RK7440-LH

LEVER HANDLE

1

2

RK7440-LP

LOOP HANDLE

1

3

RK7440-3

RETAINING NUT ASSY.
RETAINING NUT

1

RETAINING GASKET

1

ESCUTCHEON

1

4

RK7440-

CART

CARTRIDGE ASSEMBLY WITH LIMIT STOP

1

5

RK7440-94

AERATOR, STD 2.2 GPM
AERATOR

1

WASHER

1

RK7440-94-

VP1.5

AERATOR, 1.5 GPM ,
VANDAL RESISTANT
AERATOR

1

WASHER

1

RK7440-

94SO

AERATOR SPRAY OUTLET 
1.0 GPM
AERATOR

1

WASHER

1

7440-94LA

AERATOR, LAMINAR FLOW, 
2.2 GPM
AERATOR

1

WASHER

1

7440-94VP/

WK

AERATOR, VANDAL PROOF 
2.2 GPM
AERATOR

1

WASHER

1

KEY

1

7440-94FC/

WK

AERATOR, FLOW
CONTROL 0.5 GPM
AERATOR

1

WASHER

1

KEY

1

6

RK7440-90

BASE PLATE

1

7

RK7440-17

MOUNTING BRACKET ASSY.
BRACKET

2

HEX NUT

2

8

RK7440-HK

INLET NUTS

2

9

RK7440-36W

SPOUT ASSY.
SPOUT GASKET

1

WATERWAY SPOUT

1

AERATOR WASHER

1

WARNING

: Cancer and Reproductive Harm - 

www.

P65Warnings.ca.gov

ADVERTENCIA: 

Cáncer y daño reproductivo - 

www.

P65Warnings.ca.gov

AVERTISSEMENT: 

Cancer et effets néfastes sur la 

reproduction - www.P65Warnings.ca.gov

Содержание Sierra Z7440-XL-CST Series

Страница 1: ...nsult the mounting surface manufacture for their recommendation of sealant From underneath the sink position bracket on mounting studs and attach the hex nuts Tighten hex nuts 3 If faucet includes pop up or grid drain refer to next page for pop up assembly installation 4 Connect left inlet tube to hot water supply and right inlet tube to cold water supply CAUTION Care should be taken not to kink t...

Страница 2: ...nd housing gasket 3 Do not let the pop up assembly turn while tightening Remove the excess plumbers putty from the flange 5 Place gasket 10 into nut 11 Place nut 11 over rod and rod ball 9 Place seat 8 in rod ball hole Tighten nut 11 hand tight The pop up stopper 1 can be installed two different ways A removable and B non removable See stopper drawing A and B on opposite page Position stopper into...

Страница 3: ...mbly down through lavatory sink 4 Install housing gasket 2 flat gasket 3 and nut 4 Tighten nut 5 Remove excess putty from flange 1 1 Remove aerator and open valve to mixed position 2 Turn water on for 1 minute 3 Check for leaks under the sink 4 Shut off faucet and replace aerator NOTE TO INSTALLER When using vandal proof aerator VP or flow control FC keep the installation key fixed under sink or i...

Страница 4: ...is loose Water way may leak from aerator and appear under sink Tighten aerator LIMITED WARRANTY All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three 3 years from the date of purchase We will replace at no cost goods that prove defective provided we are notified in writing of such defect and the goods are returned to Zurn Industrie...

Отзывы: