1. Remove the flange (2), then thread nut (5) and fiber gasket
(4) down as far as possible. Place the housing gasket (3)
on top of fiber gasket and nut.
2. Apply teflon tape to the threaded portion of tailpiece (7) and
thread into body (6).
3. Apply putty to the underside of the flange (2). Push the pop-
up assembly through the bottom of the lavatory sink. Screw
the flange (2) onto the pop-up body (6).
4. Face the pivot hole towards the wall. Pull down on the pop-
up assembly and tighten the nut (5), fiber gasket (4) and
housing gasket (3). Do not let the pop-up assembly turn
while tightening. Remove the excess plumbers putty from
the flange.
5. Place gasket (10) into nut (11). Place nut (11) over rod and
rod ball (9). Place seat (8) in rod ball hole. Tighten nut (11)
hand tight. The pop-up stopper (1) can be installed two
different ways: (A) removable and (B) non-removable. See
stopper drawing " A" and "B" on opposite page. Position
stopper into body (6).
6. Place clip (12) over a hole in the metal strap (13). Insert the
horizontal rod (9) through both the hole in the strap (13)
and clip (12). You can bend the strap for travel adjustment.
7. Place the lift rod (15) down through the hole in the faucet
and then the strap (13). Set the desired height of push rod
and tighten the thumb screw (14).
1
2
3
4
5
6
7
15
13
14
9
10
11
8
12
METAL POP-UP INSTALLATION
ITEM
DESCRIPTION
1
STOPPER
2
FLANGE
3
HOUSING GASKET
4
FIBER GASKET
5
NUT
6
BODY
7
TAILPIECE
8
SEAT
9
ROD & BALL
10
GASKET
11
NUT
12
CLIP
13
STRAP
14
THUMB SCREW
15
LIFT ROD
METALLIC POP-UP
________________________
INSTALLATIONS INSTRUCTIONS
Form #
CF952
Date:
12/16/11
Product No.:
IS7440
C.N. No.
128418
Rev.
i
Sheet 2 of 4