background image

3.1. REMOVE CERAMIC MIXING CARTRIDGE (ITEM #4) PER MAINTENANCE INSTRUCTIONS 2.1

THROUGH 2.6 ABOVE.

3.2. REMOVE RED TEMPERATURE LIMIT RING FROM BLUE MIXING CARTRIDGE.
3.3. ROTATE RED TEMPERATURE LIMIT RING CLOCKWISE TO INCREASE MAXIMUM

TEMPERATURE OR COUNTERCLOCKWISE TO DECREASE MAXIMUM TEMPERATURE. RED
TEMPERATURE LIMIT RING IS MARKED WITH ARROWS AND +/- TO INDICATE DIRECTION OF
ROTATION AND EFFECT ON MAXIMUM TEMPERATURE.

3.4. REPLACE RED TEMPERATURE LIMIT RING IN DESIRED ORIENTATION.
3.5. REINSTALL HANDLE ASSEMBLY BY REVERSING STEPS 2.1 THROUGH 2.5.
3.6. TEST MAXIMUM TEMPERATURE FOR ACCEPTABILITY AND REPEAT STEPS 3.1 THROUGH

3.5 IF NECESSARY.

REPAIR PARTS

G66685

SINGLE CONTROL HANDLE ASSEMBLY

G60502

MOUNTING HARDWARE

G66686

CERAMIC MIXING CARTRIDGE

TROUBLE SHOOTING GUIDE

PROBLEM

CAUSE

SOLUTION

NO WATER COMES OUT
OF FAUCET SPOUT. ALL
SUPPLIES ARE ON.

CARTRIDGE
RETAINING NUT TOO
LOOSE

REMOVE FAUCET
HANDLE. TIGHTEN
CARTRIDGE RETAINING
NUT. DO NOT OVER
TIGHTEN. TIGHTEN UNTIL
NUT IS SNUG

AERATOR IS CLOGGED.

REMOVE AERATOR. REMOVE
DEBRIS AND REINSTALL
AERATOR.

WATER DEFLECTS AT
AN ANGLE FROM THE
FAUCET SPOUT

AERATOR HAS DEBRIS

REMOVE AERATOR. REMOVE
DEBRIS AND REINSTALL AERATOR.

FAUCET LEAKS FROM
UNDER FAUCET HANDLE.
ALL SUPPLIES ARE ON.

PAGE 2  OF 3