3.1. REMOVE CERAMIC MIXING CARTRIDGE (ITEM #4) PER MAINTENANCE INSTRUCTIONS 2.1
THROUGH 2.6 ABOVE.
3.2. REMOVE RED TEMPERATURE LIMIT RING FROM BLUE MIXING CARTRIDGE.
3.3. ROTATE RED TEMPERATURE LIMIT RING CLOCKWISE TO INCREASE MAXIMUM
TEMPERATURE OR COUNTERCLOCKWISE TO DECREASE MAXIMUM TEMPERATURE. RED
TEMPERATURE LIMIT RING IS MARKED WITH ARROWS AND +/- TO INDICATE DIRECTION OF
ROTATION AND EFFECT ON MAXIMUM TEMPERATURE.
3.4. REPLACE RED TEMPERATURE LIMIT RING IN DESIRED ORIENTATION.
3.5. REINSTALL HANDLE ASSEMBLY BY REVERSING STEPS 2.1 THROUGH 2.5.
3.6. TEST MAXIMUM TEMPERATURE FOR ACCEPTABILITY AND REPEAT STEPS 3.1 THROUGH
3.5 IF NECESSARY.
REPAIR PARTS
G66685
SINGLE CONTROL HANDLE ASSEMBLY
G60502
MOUNTING HARDWARE
G66686
CERAMIC MIXING CARTRIDGE
TROUBLE SHOOTING GUIDE
PROBLEM
CAUSE
SOLUTION
NO WATER COMES OUT
OF FAUCET SPOUT. ALL
SUPPLIES ARE ON.
CARTRIDGE
RETAINING NUT TOO
LOOSE
REMOVE FAUCET
HANDLE. TIGHTEN
CARTRIDGE RETAINING
NUT. DO NOT OVER
TIGHTEN. TIGHTEN UNTIL
NUT IS SNUG
AERATOR IS CLOGGED.
REMOVE AERATOR. REMOVE
DEBRIS AND REINSTALL
AERATOR.
WATER DEFLECTS AT
AN ANGLE FROM THE
FAUCET SPOUT
AERATOR HAS DEBRIS
REMOVE AERATOR. REMOVE
DEBRIS AND REINSTALL AERATOR.
FAUCET LEAKS FROM
UNDER FAUCET HANDLE.
ALL SUPPLIES ARE ON.