FV746   Rev. A   11/10/20

Page  1    

Prior to installing the ZER Flushometer, install the

items listed below:

• Closet or urinal fixture

• Drain line

• Water supply line

IMPORTANT

:

• ALL PLUMBING IS TO BE INSTALLED IN ACCORDANCE WITH 

APPLICABLE CODES AND REGULATIONS.

•  WATER  SUPPLY  LINES  MUST  BE  SIZED TO  PROVIDE AN 

ADEQUATE VOLUME OF WATER FOR EACH FIXTURE.

• FLUSH ALL WATER LINES PRIOR TO OPERATION (See Step 9).

• DIRT AND DEBRIS CAN CAUSE FLUSH VALVE TO RUN CON

-

TINUOUSLY.

Prior to Installation

Sweat Solder Adapter Installation Instructions

1. Measure distance from finished wall to the center line of the fixture 

spud.  If necessary, cut water supply pipe 1-1/4” shorter than this 

measurement. Deburr by chamfering O.D. and I.D of end of water 

supply pipe.

NOTE: Before installation, turn off water supplies to existing fixture and remove flushometer if replacing an existing device.

Finished 

Wall

Water Supply Pipe

Center Line

of Fixture 

Spud

1

1

4

“ 

Sweat Solder 

Adapter

Set Screw

Chrome Cover Tube

Wall Escutcheon

Distance to 

Measure

2. Slide threaded sweat solder adapter onto water supply pipe until 

shoulder stops on end of pipe. Then sweat-solder the adapter to 

water supply pipe. 

3. Measure distance from finished wall to first thread of sweat solder 

adapter.  If necessary, cut chrome cover tube this length.

4. Slide wall escutcheon over chrome cover tube and slide both 

items over water supply pipe.  Press wall escutcheon flush against 

finished wall and tighten set screw with hex wrench (supplied) to 

secure it in place.

Содержание AquaSense ZER-W2 Series

Страница 1: ... and use the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantability is limited to a period of three years and shall b...

Страница 2: ...mmunications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase t...

Страница 3: ...r than this measurement Deburr by chamfering O D and I D of end of water supply pipe NOTE Before installation turn off water supplies to existing fixture and remove flushometer if replacing an existing device Finished Wall Water Supply Pipe Center Line of Fixture Spud 11 4 Sweat Solder Adapter Set Screw Chrome Cover Tube Wall Escutcheon Distance to Measure 2 Slide threaded sweat solder adapter ont...

Страница 4: ... to control stop inspect and verify that the O ring seal is located within the O ring groove at the tailpiece Ensure that the locking nut and locking snap ring are also present on the tailpiece Flush Valve Installation Instructions Lubricate O ring with water if necessary and insert flush valve tailpiece into the control stop valve Tighten locking nut using a smooth jawed wrench Vacuum Breaker Tub...

Страница 5: ...e adjustment of the activation distance see Appendix A Adjusting Your E Z Flush The E Z Flush unit has a 10 minute start up sequence in which the Object Lock Sensor will flash the User In View yellow L E D continuously as long as a user is in view After the start up sequence is completed and when the Object Lock Sensor has a user in view the User In View yellow L E D will flash only 3 times after ...

Страница 6: ... valve shown on the right 3 Replace the plastic cover and main body cover without reinstall ing the working parts 4 Open the stop valve by using the stop adjusting screw and flush out all debris from pipe and connections 5 Shut stop open cover reinstall the working parts replace both covers and tighten This procedure should also be repeated when the system is drained for seasonal use as occurs in ...

Страница 7: ...esired activation distance 6 Use sensor adjustor tool and turn Distance Adjustment Screw all the way down and then turn slowly up until yellow L E D begins to flash 7 Ensure Object Lock Sensor is not detecting stall door or wall by closing door stepping out of sensor path and making sure yellow L E D is not flashing If sensor locks onto door or wall unit will not flush properly Shorten activation ...

Страница 8: ...faces such as metal weaken the signal between the gateway and other devices The LoRa antenna is an omni directional antenna but for best results mount the device so the LoRa antenna is in a vertical position near the top of a wall We recommend conducting a site survey to test the signal strength in different locations before you mount the device Step 4 Mounting the Zurn Gateway The device ships wi...

Страница 9: ...eries are dead Replace batteries If the E Z Flush does not begin to function call Cus tomer Service at 1 800 997 3876 Flush Valve Trouble Shooting Guide Problem Corrective Action Status Good posted in plumbSMART and faucet actuation event data not appearing in plumbSMART 2 hours or Device Not Communicating warning or severe alert posted in plumbSMART for all devices 3 hours Step 1 Verify gateway S...

Страница 10: ...aucet actuator electronics Restore proper electrical connection as needed Step 2 Test activate the faucet If problem persists see Faucet Troubleshooting section in this guide for other steps Status Good posted in plumbSMART and faucet actuates but usage event data not appearing in plumbSMART Charts Step 1 Verify gateway is powered and LoRa Status LED is ON If not apply power per Zurn Gateway Insta...

Страница 11: ...t 1 0 gal flush P6000 EUA WS1 Water Saving Urinal Kit 1 5 gal flush P6000 EUA WS Full Flush Urinal Kit 3 0 gal flush P6000 EUA FF Repair Parts Inside Parts Product No Urinal Relief Valve Item 12 P6000 EU13 Closet Relief Valve Item 12 P6000 EC13 Flush Connections and Spud Coupling Kits Product No Flush Tube Assembly for Flush Valves Includes Items 15 19 Specify Diameter and Length P6000 A Vacuum Br...

Страница 12: ...STRIES LLC 511 W Freshwater Way Milwaukee WI U S A 53204 Ph 1 855 ONE ZURN Fax 919 775 3541 In Canada ZURN INDUSTRIES LIMITED 7900 Goreway Drive Unit 10 Brampton Ontario L6T 5W6 Ph 905 405 8272 Fax 905 405 1292 Rev A Date 11 10 20 C N No NEW Prod Dwg No FV746 ...

Отзывы: