ZURN Aquaflush Z6100 Series Скачать руководство пользователя страница 5

FV251 Rev. B  7/9/18

Page  5    

Note:  Due to the high back pressures that can be created by concealed fixtures, this procedure must be followed when installing scored flush 

tubes.  Failure to follow these instructions can result in plumbing separation at the elbow.

For all Zurn concealed and concealed penal fixture valves with 1 1/2” flush connections.

When cutting scored vacuum breaker and horizontal connection tubes to fit, always leave at least 1 3/4” (32mm) of scoring to insure proper en

-

gagement with the compression coupling.

Install fixture flush connection. (Figure 1)  Zurn penal flushometers are designed to connect to the stainless steel fixture in a chase behind the wall.  

A 1 1/2” pipe connection (not supplied by Zurn) must be used to connect the fixture inlet to the flanged/scored horizontal tube.

Loosely assemble the concealed plumbing after placing all of the nuts, friction washers, and gaskets in place.  This will locate the gaskets prior to 

applying the Loctite adhesive.

Disassemble the plumbing and put a 1/8” wide bead of the adhesive around the scoring between the gasket and the end of both tubes. (Figure 2)  

Make sure the tubes and elbow are clean and dry before using the adhesive.  DO NOT use any other pipe sealant or lubrication on these points.

Assemble the horizontal tube to the fixure and tighten securely.  Slip the elbow onto the horizontal tube rotating it as pushing in to the gasket to 

spread the adhesive.  Leave the elbow at an angle so the vacuum breaker tube can be inserted.  Insert the vacuum breaker into the vacuum tube 

and the tube into the elbow, rotating it to spread the adhesive.  Screw all nuts into place and tighten.  The adhesive has a limited (2 minute) working 

time so tighten the connections immediately.

Figure 1

Figure 2

Scored Tubing Installaion Instructions

RUBBER

GASKET

COUPLING NUT

PLASTIC

FRICTION

WASHER

P-30

GASKET

Coupling

Nut

Pipe Connection

(1 1/2" I.P.S.)

Not Supplied by Zurn

(Supplied to

customer spec.)

Fixture

Side of

Wall

Содержание Aquaflush Z6100 Series

Страница 1: ...the purchaser shall determine the suitability of the product for his intended use and the purchaser assume all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantabi lity is limited to a period of three years and shall be limited...

Страница 2: ... of chloramine resistant materials MODELS Z6140 1 1 2 Water Closet valve with back spud connection Z6152 1 1 2 Water Closet valve with back spud connection Z6190 1 1 4 Urinal Valve with top spud connection Z6195 3 4 Urinal Valve with top spud connection FLOWS WS1 Low Consumption 1 0 Gal for Urinal 1 6 Gal for Water Closet WS Water Saver 1 5 Gal for Urinal 3 5 Gal for Water Closet Standard Flow FF ...

Страница 3: ...older adaptor sweat the adaptor to the copper tubing before installing the control stop 2 Attach vacuum breaker tube and elbows to fixture with spud nut Note When cutting scored pipe to fit leave a minimum of 1 1 4 of scoring to ensure proper engagement with compression coupling and follow scored tubing loctite instruction See page 5 3 Remove the actuator end coupling and mounting nut form the act...

Страница 4: ... is 18 gage stainless steel Both have a satin finish The assembly comes complete with 4 1 25 mm vandal proof screws Specify Z6199 BX12 for 12 x 12 Z6199 BX15 for 15 x 15 or Z6199 BX17 for 13 x 17 E E A C D F F B 1 1 4 31 8 1 1 2 38 1 HOLE W WALL THICKNESS L DIMENSION SPECIFY FINISHED WALL Closets Urinals Combination Fixtures Wall Thickness W 6140 6152 6681 6142 6154 6602 6143 6155 6609 6601 6144 6...

Страница 5: ...shers and gaskets in place This will locate the gaskets prior to applying the Loctite adhesive Disassemble the plumbing and put a 1 8 wide bead of the adhesive around the scoring between the gasket and the end of both tubes Figure 2 Make sure the tubes and elbow are clean and dry before using the adhesive DO NOT use any other pipe sealant or lubrication on these points Assemble the horizontal tube...

Страница 6: ...arged by pass orifice 2 Install new P6000 ECR P6000 EUR replacement kit to remedy the problem 3 Urinal trip mechanism black 12 in closet flush valves 3 Install closet trip mechanism white Valve is flushing too long or not shutting off 1 Trip mechanism not seating properly due to foreign material between trip mechanism and retainer disc 1 Disassemble parts and rinse thoroughly 2 By pass orifice is ...

Страница 7: ...000 EU WS Full Flush Urinal Kit 3 0 gal flush P6000 EU FF Repair Parts Inside Parts Product No Urinal Relief Valve Item 18 P6000 EU13 Closet Relief Valve Item 18 P6000 EC13 Aquaflush Rebuild Kits Product No Closet and Urinal Rebuild Kits Include P6000 EC WS RK Items 10 15 18 19 35 38 39 P6000 EC WS1 RK P6000 EU WS RK P6000 EU WS1 RK Handle Assembly and Repair Kits Product No Concealed Valve Actuat...

Отзывы: