background image

www.zuhne.com

iCHORUS 36 Island Hood

9

 

MAINTENANCE

 

 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Proper  maintenance  of  the  Range  Hood 

will assure proper performance of the unit.   

Filters   

The filters must be cleaned approximately 

once  every  30  hours  of  operation  (when 

the  central  segment  on  the  display  goes 

on or starts blinking).   

Use  a  warm  detergent  solution.  Grease 

filters are dishwasher safe.   
Remove filter by pushing filter towards the 

back of hood and rotating filter downward.   

 

Duct free(Carbon) Filters 

The duct free filters should be changed every 6 months. Rotate the filters to remove and replace. 

 

Hood Cleaning   

Stainless steel is one of the easiest materials 

to keep clean. Occasional care will help preserve its fine appearance. 

Cleaning tips: 

 

-

  Hot water with soap or detergent is all that is usually needed.   

-

  Follow all cleaning by rinsing with clear water. Wipe dry with a clean, soft cloth to 

avoid water marks.   

-

  For discolorations or deposits that persist, use a non-scratching household cleanser 

or stainless steel polishing powder with a little water and a soft cloth.   

-

  For  stubborn  cases,  use  a  plastic  scouring  pad  or  soft  bristle  brush  together  with 

cleaner and water. Rub lightly in direction of polishing lines or "grain" of the stainless 

finish. Avoid using too much pressure which may mar the surface.   

-

  DO NOT allow deposits to remain for long periods of time.   

-

  DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to 

the surface causing rust.   

-

  DO  NOT  allow  salt  solutions,  disinfectants,  bleaches,  or  cleaning  compounds  to 

remain  in  contact  with  stainless  steel  for  extended  periods.  Many  of  these  com

pounds  contain  chemicals  which  may  be  harmful.  Rinse  with  water  after  exposure 

and wipe dry with a clean cloth.   

 

Painted surfaces should be cleaned with warm water and mild detergent only. 

 

Содержание iCHORUS

Страница 1: ...zuhne 1 855 55 ZUHNE www zuhne com Installation and Use Manual ISLAND HOOD iCHORUS ...

Страница 2: ...Ducted fans must always be vented to the outdoors 7 Do not use this unit with any separate solid state speed control device 8 To reduce the risk of fire use only metal ductwork 9 This unit must be grounded TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE A Never leave surface units unattended at high settings Over heat cause smoking and greasy spillovers that may ignite Heat oils slowly on low or med...

Страница 3: ...load which will automatically shut off the motor if it becomes overheated The motor will restart when it cools down If the motor continues to shut off and restart have the hood serviced 7 For best capture of cooking impurities the bottom of the hood should be a minimum of 24 and a maximum of 33 above the cooking surface 8 Two installers are recommended because of the large size and weight of this ...

Страница 4: ...ng Screws 6 x 45mm for wooded ceiling 12 Drywall Anchors 8 Explode Screws for concrete ceiling installation 42 Mounting Screws 4 x 14mm 26 pcs for set of washer and nut 2 pcs for spare 26 Washer 2 pcs for spare 26 Nut 2 pcs for spare 8 Mounting Screws 4 x 8mm for φ8 holes 1 Aluminum Flex Duct MOUNTING SCREWS 4 X 8MM DRYWALL ANCHORS NUT WASHER MOUNTING SCREWS 6 X 45MM ALUMINUM FLEX DUCT MOUNTING PL...

Страница 5: ...d be installed by a qualified electrician in accordance with all applicable national and local electrical codes The minimum hood distance above cooktop must not be less than 24 A maximum of 33 above cooktop is highly recommended for best capture of cooking impurities Distances over 33 are at the installer and users discretion ...

Страница 6: ... use 8 pcs of mounting screws 4 14mm with washers and nuts to fixe 4 pcs angle iron onto the mounting plate 4 Adjust the height X of the chimney as shown on the picture 1 use 16 pcs of munting screws 4 14mm with washers and nuts to fixe the other 4 pcs angle iron onto the angle irons which have been installed INSTALL THE DUCTWORK NOTE To reduce the risk of fire use only metal ductwork 1 Decide whe...

Страница 7: ... the chimneys put the inside chimney through the angle irons and up to the ceiling use 4 pcs of mounting screws 4 8mm to fix the chimney onto the mounting plate See picture shown 2 Put the outside chimney onto the inside chimney and use the S hook to fix on the angle iron See picture shown ...

Страница 8: ...and decorative flues prior to final installation 1 Pick out the hood from the carton 2 Install the vent into the duct connector of the cooker hood with 4 pcs mounting screws 4 8mm INSTALL THE HOOD Note at least two people will be required to mount the hood 1 Raise the hood into its mounting position 2 Fix the hood onto the angle irons with 16 pcs of mounting screws 4 14mm See picture as shown ...

Страница 9: ...ww zuhne com iCHORUS 36 Island Hood 8 INSTALLATION PROCEDURE 3 Pull the duct as the direction showed on the picture and make it fix onto the vent 4 Loose the S hook and pull the outside chimney as shown ...

Страница 10: ...ing by rinsing with clear water Wipe dry with a clean soft cloth to avoid water marks For discolorations or deposits that persist use a non scratching household cleanser or stainless steel polishing powder with a little water and a soft cloth For stubborn cases use a plastic scouring pad or soft bristle brush together with cleaner and water Rub lightly in direction of polishing lines or grain of t...

Страница 11: ...hood will enter stand by mode 2 Press button once lights will be on Press button again lights will be off 3 Push the low button the indicating light and the motor runs at low speed Push it again and the motor will stop 4 Push the middle button the indicating light and the motor runs at mid speed Push it again and the motor will stop 5 Push the high button the indicating light and motor runs on hig...

Страница 12: ...TY SUPPLY BEFORE CARRYING OUT ANY OPERATIONS ON THE APPLIANCE To change the light 1 Open the filter and find the spring of the light push the spring and the lgight will be slip out Change the light as with same kind of 4Volt 3 Watt LED light CAUTION LIGHT MAY BE HOT PLEASE ROTATE WHEN THELIGHT IS COOL ...

Страница 13: ...ance are not tightly sealed Take down the one way valve and seal with glue Leakage from the connection of U shaped section and cover Take U shaped section down and seal with soap or paint Shake of the body The leaf damaged and causes shaking Replace the leaf The motor is not tightly hanged Lock the motor tightly The body is not tightly hanged Fixed the body tightly Insufficient suction The distanc...