Chapter 2 Alarm
2.3.10 6213 Board inserted incorrectly
Alarm Property
l
Alarm Code: 6213
l
Alarm Information: When the main control board detects that the board inserted at
front-end differs from the actually configured board, this alarm is reported.
l
Alarm Level: Major
l
Alarm Type: Handling Alarm
Sub-code Description
l
Sub-code 1: The board actually inserted is different from that configured in the network
management system.
l
Sub-code 2: The type of the board actually inserted is different from that configured
in the network management system.
Effect on the System
The board cannot operate properly, and the services carried by the board are interrupted.
Possible Causes
The board type configuration at NetWork Management is incorrect, or the board is
incorrectly inserted.
Handling Procedure
1.
On the LMT, select
Setup > Shelf
and check whether the board configuration is correct.
l
If yes, go to step 2.
l
If no, correct the configuration.
2.
Replace the incorrect boards.
2.3.11 6214 Software version abnormal
Alarm Property
l
Alarm Code: 6214
l
Alarm Information: If the software version consistency check indicates that the version
in software package does not exist on the disk or is damaged, this alarm is reported.
l
Alarm Level: Major
l
Alarm Type: Handling Alarm
Sub-code Description
l
Sub-code 1: The active software package is incorrect
l
Sub-code 2: The running patch package of the active software package is incorrect
l
Sub-code 3: The standby patch package of the active software package is incorrect
2-67
SJ-20111008094748-008|2012–05–30 (R1.1)
ZTE Proprietary and Confidential