ZXMW NR8250 Alarm and Notification Handling Reference
l
136183808. E1-16 port (LMT displays “E1-30”)
l
136249344. E1-16 port (LMT displays “E1-31”)
l
136314880. E1-16 port (LMT displays “E1-32”)
l
268500992. optical port 1 (LMT displays “STM1-1”);
l
268566528. optical port 2 (The rate is STM1 and LMT displays “STM1-2”.);
l
335675392. optical port 2 (The rate is STM4 and LMT displays “STM4-2”);
l
335680000.
optical port 2, path 1 (The rate is STM4 and LMT displays
“STM4-Channel-1”.);
l
335679616.
optical port 2 , path 2 (The rate is STM4 and LMT displays
“STM4-Channel-2”.);
l
335679744.
optical port 2, path 3 (The rate is STM4 and LMT displays
“STM4-Channel-3”.);
l
335679872.
optical port 2, path 4 (The rate is STM4 and LMT displays
“STM4-Channel-4”.).
Effect on the System
Traffic is interrupted when the wireless link port is in loopback status.
Possible Causes
1.
The loopback function is enabled for testing or maintenance.
2.
The board that reports the alarm is faulty.
Handling Procedure
1.
Check whether loopback is configured for test or maintenance.
l
If yes, after the maintenance or test is completed, disable the loopback function.
(Path:
Maintenance > TDM Traffic
).
l
If no, go to step 2.
2.
The RTUA/RTUB/RTUC/RTUH board of NR8250 equipment is faulty. Replace the
board.
2.1.12 134237782 SNCP route setting alarm
Alarm Property
l
Alarm Code: 134237782
l
Alarm Information: The alarm is reported if the SNCP route setting fails.
l
Alarm Level: Critical
l
Alarm Type: Equipment Alarm
Sub-code Description
None
2-10
SJ-20111008094748-008|2012–05–30 (R1.1)
ZTE Proprietary and Confidential