Chapter 6 Cable Installation
Figure 6-17 Rear Board for Clock Panel Uses 75 Ohms Micro Coaxial Cable
structure with Version 071200
Cable connection relationship is shown in
Table 6-4 Clock Panel Rear Board Uses 75 Ohms Micro Coaxial Cable
Connection with Version 071200
End A
End B
Signal Name
A1 core
1
2MB+
A1 Shielded
6
2MB-
A2 core
8
2MH+
A2 Shielded
4
2MH-
Steps
1.
Connect End A of the cable.
End A connects BITS clock source from office side. You shall select the terminal based
on demands. That is to say, the clock cable terminal for 2MHz signal at end A connects
2MHz clock source and the clock cable terminal for 2MBits signal connects the E1
clock signal for 2Mbits.
2.
Connect End B of the cable.
l
For the rear board for clock board with version 040503, DB9 at end B connects
the position with stamp 2MBps/2MHz for RCKG1.
l
For the rear board for clock board with version 071200, DB9 at end B connects
the position with stamp BITS REF for RCKG1 and RCKG2.
– End of Steps –