background image

5

Connect power cable(s) and turn 

on the NSC

Connect power cable(s) between the 

appliance and your power source(s). 

Turn on the power switch(es).

6

Connect to the Serial Console port

Using an RJ-45 console adaptor, 

connect a terminal or workstation to 

the serial console port on the NSC. The 

NSC will be configured using a terminal 

or terminal emulator with session 

settings of: 115,200, 8, N and 1, with 

no flow control.

Note

: All remaining manual setup 

steps are required the first time you 

configure your NSC.

7

Configure network parameters

NOTE

: Skip to 

step 8

if you have a 

DHCP environment. DHCP is the default 

IP configuration. If no DHCP server is 

available, please log in to NodeGrid 

Serial Console using 

admin 

credentials 

(you will be required to change 

password on the first login) and 

configure a static IP address using CLI 

instructions as follows:

[admin@nodegrid /]# 

cd 

settings/network_interfaces/eth0/ 

[admin@nodegrid eth0]# 

set 

ipv4_mode=static

[admin@nodegrid eth0]# 

set 

ipv4_address=10.0.0.10 
ipv4_mask=255.255.255.0 
ipv4_gateway=10.0.0.1

[admin@nodegrid eth0]# 

show

interface: eth0
mac address: 08:00:27:c4:cf:e5
status = enabled
ipv4_mode = static
ipv4_address = 10.0.0.10
ipv4_mask = 255.255.255.0
ipv4_gateway = 10.0.0.1
ipv6_mode = no_ipv6_address
[admin@nodegrid eth0]# 

commit

[admin@nodegrid eth0]# 

exit

Connect to the NSC console port. Login 

as root to change the root password.

8

Configure serial, network & USB 

devices
Note

: Your NSC will respond over the 

network at 

192.168.160.10

if your 

DHCP server fails or is unavailable. 

Note:

To check your current IP address, 

connect to the NSC console port and 

hit 

Enter

at the login prompt until you 

see the IP address.
To configure the NSC T-Series for the 

first time via Network:
a) Open a web browser (HTTP/S) and 

enter its IP address in the address field. 

Or start an SSH session to your NSC’s IP 

address. 
b) Log in to your NSC as 

admin. 

You 

will be required to change password 

on the first login.
Set your system security options as 

described below.

Step 1 - Security

Security services tab: Select the 

desired services, cryptographic 

protocols and cipher suite levels. Click 

Save 

when finished.

Step 2 - Network

Network settings tab: Set your desired 

Network and Interfaces parameters. 

Click 

Save 

for each submenu.

Step 3 - Ports

Managed Devices tab: Select local 

serial console port checkboxes and 

click “Edit.” Set your preferences and 

click 

Save 

when finished.

Step 4 - Change Admin Password

At any time, click 

[email protected]

in the upper right corner of your 

screen and click “Change Password” to 

change your system password. 

Note:

Connect to the NSC console 

port. Login as root to change the root 

password.

Congratulations! 

Your NodeGrid Serial Console is now 

configured and ready to accept users 

and connections to its ports. 

9

Additional Configuration

NOTE:

We recommend that you set up 

new

Administrator account (in 

admin

group with full privileges) and use the 

new account instead of the default 

admin

account. 

Add New Users

Click Security tab, Local Accounts, Add, 

set options, 

Save.

Alerts & logging

Set and send alerts by email, SMS, 

and/or SNMP. 

Power

Control network attached PDU power 

strips and server, network and storage  

devices.

For additional configuration options, 

how-tos and tips please refer to your 

NSC User Guide.

10

Get technical updates

To automatically receive future 

firmware updates and technical 

information, sign up here: 

www.zpesystems.com/loop/

Quick Start Guide for T Series NodeGrid Serial Console

Contact ZPE Technical Support at [email protected]

www.zpesystems.com/resources/support/